PubMed Health⌕ Search

Biomedical subjects

Mike S Lee

Publications and source records attributed to Mike S Lee.

2 recordsLinked to original sources

Ultra-low flow nanospray for the normalization of conventional liquid chromatography/mass spectrometry through equimolar response: standard-free quantitative estimation of metabolite levels in drug discovery.

Nanospray experiments were performed on an ensemble of drug molecules and their commonly known metabolites to compare performance with conventional electrospray ionization (ESI) and to evaluate equimolar response capabilities. Codeine, dextromethorphan, tolbutamide, phenobarbital, cocaine, and morphine were analyzed along with their well-known metabolites that were formed via hydroxylation, dealkylation, hydrolysis, and glucuronidation. Nanospray exhibited a distinct trend toward equimolar response when flow rate was reduced from 25 nL/min to less than 10 nL/min. A more uniform response between the parent drug and the corresponding metabolites was obtained at flow rates of 10 nL/min or lower. The largest discrepancy was within +/-50% for plasma samples. Nanospray was used as a calibrator for conventional ESI liquid chromatography/tandem mass spectrometry (LC/MS/MS) and normalization factors were applied to the quantitation of an acyl-glucuronide metabolite of a proprietary compound in rat plasma. A nanospray calibration method was developed with the standard curve of the parent drug to generate quantitative results for drug metabolites within +/-20% of that obtained with reference standards and conventional ESI. The nanospray method provides a practical solution for the quantitative estimation of drug metabolites in drug discovery when reference standards are not available.

Calibration↗

Automated orthogonal control system for electrospray ionization.

Low-flow electrospray ionization is typically a purely electrostatic method, used without supporting sheath-gas nebulization. Complex spray morphology results from a large number of possible spray emission modes. Spray morphology may assume the optimal Taylor cone-jet spray mode under equilibrium conditions. When coupling to nanobore gradient elution chromatography, however, stability of the Taylor cone-jet spray mode is compromised by the gradient of mobile phase physiochemical properties. The common spray modes for aqueous/organic mobile phases were characterized using orthogonal (strobed illumination) transmitted light and (continuous illumination) scattered light imaging. Correlation of image sets from these complementary illumination methods provides the basis for spray mode identification using qualitative and quantitative image analysis. An automated feedback-controlled electrospray source was developed on a computer capable of controlling electrospray potential using an image-processing based algorithm for spray mode identification. The implementation of the feedback loop results in a system that is both self-starting and self-tuning for a specific spray mode or modes. Thus, changes in mobile phase composition and/or flow rate are compensated in real-time and the source is maintained in the cone-jet or pulsed cone-jet spray modes.

Angiotensins↗