Control strategy for maintaining physiological perfusion with rotary blood pumps.

We present arguments and simulation results in favor of a novel strategy for control of rotary blood pumps. We suggest that physiological perfusion is achieved when the blood pump is controlled to maintain an average reference differential pressure. In the case of rotary left ventricular assist devices, our simulations show that maintaining a constant average pressure difference between the left ventricle and aorta results in physiological perfusion over a wide range of physical activities and clinical cardiac conditions. We simulated rest, light, and strenuous exercise conditions, corresponding to cardiac demands of 4.92, 7.98, and 14.62 L/min, respectively. For different exercise levels, the clinical conditions ranged from normal to failing to asystolic heart. By maintaining a constant pressure difference of 75 mm Hg between the left ventricle and aorta, with either an axial or a centrifugal blood pump, a total cardiac output close to the physiological cardiac demand was achieved, irrespective of the heart condition. The simulations of the transitions between different levels of exercise indicate that with the same reference differential pressure, the proposed approach leads to rapid adaptation of the total cardiac output to physiological levels, while avoiding suction. Comparison with the traditional control strategy of maintaining a reference rotational speed (rpm) of the pump indicates that though the traditional approach has some degree of adaptability, it is only adequate over a narrow range of cardiac demand and clinical conditions of the patient. Our results indicate that the proposed approach is superior to the alternatives in providing an adequate and autonomous adaptation of the total cardiac output over a broad range of exercise conditions (expected when an assist device is used as a destination therapy) and clinical statuses of the native heart (such as further deterioration or recovery of cardiac function), while having the potential to improve the quality of life of patients by reducing the need for monitoring and frequent human intervention. The proposed approach can be clinically implemented using simple controllers, and requires the implantation of two pressure sensors, or estimation of the pressure difference based on other available measurements.

Biomechanical Phenomena↗

Nonlinear controller for ventricular assist devices.

This paper presents the design of a gain-scheduled proportional integral (PI) feedback controller for ventricular assist devices to maintain physiologically motivated perfusion. The selected control objective is to maintain an average differential pressure deltaP between the left ventricle and the aorta. Computer simulations for different pathological conditions, ranging from the normal heart to left heart asystole, and a wide range of physiological scenarios, ranging from rest to strenuous exercise, were used to validate the performance of the controller and the effectiveness of the selected control objective in ensuring physiologically adequate perfusion under different clinical and cardiac demand conditions.

Aorta↗

Model-predictive control of hyperthermia treatments.

A model-predictive controller (MPC) of the thermal dose in hyperthermia cancer treatments has been developed and evaluated using simulations with one-point and one-dimensional models of a tumor. The developed controller is the first effort in: 1) the application of feedback control to pulsed, high-temperature hyperthermia treatments; 2) the direct control of the treatment thermal dose rather than the treatment temperatures; and 3) the application of MPC to hyperthermia treatments. Simulations were performed with different blood flow rates in the tumor and constraints on temperatures in normal tissues. The results demonstrate that 1) thermal dose can be controlled in the presence of plant-model mismatch and 2) constraints on the maximum allowable temperatures in normal tissue and/or the pulsed power magnitude can be directly incorporated into MPC and met while delivering the desired thermal dose to the tumor. For relatively high blood flow rates and low transducer surface intensities--factors that limit the range of temperature variations in the tumor, the linear MPC, obtained by piece-wise linearization of the dose-temperature relationship, provides an adequate performance. For large temperature variations, the development of nonlinear MPC is necessary.

Computer Simulation↗

Modeling and control of a brushless DC axial flow ventricular assist device.

This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.

Equipment Design↗