PubMed Health⌕ Search

Biomedical subjects

Mikio Ninomiya

Publications and source records attributed to Mikio Ninomiya.

13 recordsLinked to original sources

Sternum lifting technique for thoracoscopic internal thoracic artery harvest.

We employed the Laparolift and Laparofan (Origin Medsystems Inc., CA, USA) and developed a sternum lifting technique to create a sufficient intra-pleural space between the heart and the sternum in which the left internal thoracic artery (ITA) in situ graft could be thoracoscopically mobilized. Between June and December 2004, this technique was applied to 12 consecutive patients (eight men, four women, aged 68.5+/-9.6 years) undergoing minimally invasive coronary artery bypass grafting via a left mini-thoracotomy. The Laparofan, connected to the arm of the lift machine (Laparolift), was introduced through a subxyphoidal entry and opened beneath the sternum. The sternum was elevated by about 5 cm until a sufficient working space was created under the sternum. With left hemipulmonary collapse, the left ITA was thoracoscopically taken down through the axillary ports. There was no procedural conversion to direct harvesting. The mean thoracoscopic harvesting time was 34.5+/-7.7 min. There was no mortality and no instrument-related morbidities. Patency of each ITA graft was angiographically confirmed. In conclusion, despite the limited experience, the present sternum elevation technique using the Laparolift system is a viable method for increasing the intra-pleural working space beneath the sternum during thoracoscopic ITA harvesting.

Aged↗

VATS thoracic-duct division for aortic surgery-related chylous leakage.

Traumatic chylothorax is a serious morbidity due to aortic surgery. We treated this complication successfully by supradiaphragmatic thoracic-duct division in five adults (three men, two women, aged 61.5+/-19.5 years) and a 3-year-old male infant after an average interval of 4.1+/-1.8 days following initial aortic surgery: graft-replacement of subclavian or descending aortic aneurysm in the adults, and correction of aortic coarctation in the infant. A right thoracoscopic approach was used in the adults and the left thoracotomy was re-used in the infant. Individual exposure and division of the thoracic duct was accomplished using an ultrasonic coagulator. The operating time was 22+/-5.5 min for the thoracoscopy cases, and 70 min for the infant. There was no mortality and no procedure-related morbidity, and chylous leakage ceased immediately in all patients. There was no recurrence of chylothorax during a mean follow-up period of 17+/-9.7 months. Despite our limited experience, we conclude that the present supradiaphragmatic thoracic duct division technique (right thoracoscopy in adults) is safe and perfectly effective, and therefore prompt application of this method is recommendable for treatment of aortic surgery-related traumatic chylo-leakage, particularly in vulnerable elderly or infant patients.

Aortic Aneurysm↗

A new needle driver for minientry coronary artery bypass.

PURPOSE: This article describes our clinical experience with a new needle driver (Olympus, Tokyo, Japan), which we have produced to facilitate minithoracotomy or port-access coronary artery anastomosis with the running suture technique. METHODS: The needle driver is 21 cm long, weighs 38 g, and has a grip shaft 1.4 cm in diameter. The device is held like a pencil. A side lever and a revolving disk in the shaft are manipulated with the fingers; a fine needle with a 7-0/8-0 monofilament suture can be grasped/released and driven to penetrate the coronary arterial wall. This device was employed in 10 consecutive patients (8 men, 2 women, 73 +/- 7.5 years old), and off-pump bypass to the left anterior descending artery was achieved using the left internal thoracic artery or vein via a minithoracotomy (4.2 +/- 0.6 cm long). RESULTS: There was no instrument-related injury during each anastomosis. The mean sewing time per anastomosis was 12 minutes (range, 8-18 minutes). Angiography confirmed the patency of the graft in all cases. CONCLUSIONS: Although our experience is limited, we consider the present needle driver to be a viable device for facilitating off-pump, minientry coronary artery anastomosis with the suturing technique.

Anastomosis, Surgical↗

Open retroperitoneal irrigation for graft infection after thoracoabdominal aortic aneurysm repair.

A successfully-treated case of graft infection after thoracoabdominal aortic repair is reported. A 61-year-old male underwent graft replacement of a Crawford type IV thoracoabdominal aortic aneurysm and developed graft infection due to methicillin-resistant Staphylococcus aureus. After 35 days' open retroperitoneal irrigation, the culture around the graft turned negative, and omental transposition and skin flap transfer were successfully conducted. The long-term open retroperitoneal irrigation could be conducted without significant complications, and it was very effective in controlling the severe infection.

Aortic Aneurysm, Abdominal↗

Left atrial dissection after double valve replacement.

Left atrial dissection, a rare complication occurring mainly after mitral repair, is reported after double valve replacement in a patient with a connective tissue disease. A 63-year-old woman with systemic sclerosis underwent double valve replacement. Laceration of the tissue between the two mechanical prostheses and dissection of the left atrial wall emerged postoperatively and regurgitation through the dissection caused heart failure, which later improved without surgery. The possible causes of the dissection were thought to be shear forces against the tissue between the two prostheses and tissue fragility due to systemic sclerosis and corticosteroid therapy.

Aortic Valve Stenosis↗

Influence of PMEA-coated bypass circuits on perioperative inflammatory response.

BACKGROUND: Poly(2-methoxyethylacrylate) (PMEA) is a new coating material, and several experimental studies have revealed excellent biocompatibility of PMEA-coated cardiopulmonary bypass circuits. The clinical utility of the PMEA-coated circuits was compared with that of uncoated circuits, focusing on perioperative inflammatory response. METHODS: Twenty-two patients were randomized to PMEA-coated (group P; Capiox RX25; n = 11) or uncoated (group U; Capiox SX10; n = 11) circuit group, and underwent coronary artery bypass grafting and/or valve operations. The following markers, as well as clinical outcomes, were analyzed perioperatively: (a) complement activation by C3a (including C3a-desArg) concentrations; (b) leukocyte activation by polymorphonuclear-elastase concentrations; (c) acute phase inflammatory response by interleukin-6 concentrations; and (d) platelet preservation by number of platelets. RESULTS: The maximal values of C3a and polymorphonuclear-elastase were significantly lower in group P than in group U. The intergroup difference of interleukin-6 was not significant. Although preservation of platelets was significantly better in group P until 1 hour after initiating cardiopulmonary bypass, no significant intergroup difference was observed thereafter. The duration of postoperative mechanical ventilation revealed no significant intergroup difference. CONCLUSIONS: The PMEA-coated circuits exhibited better suppression of perioperative complement and leukocyte activation than the uncoated circuits. In addition, the price of the PMEA-coated circuits is the same as that of the uncoated circuits. Therefore, we judged that the clinical utility of the PMEA-coated circuits is superior to those of the uncoated circuits.

Aged↗

Needle-guided mini-entry in video-assisted coronary artery bypass.

In minimally invasive coronary artery bypass (MICAB), a video-assisted needle-guided technique was used to make a mini-thoracotomy or an access-port just above the target site in the left anterior descending coronary artery (LAD). After thoracoscopic preparation of the left internal thoracic artery (LITA) and pericardiotomy, a 7-cm, 23-gauge needle was used to examine the skin-point where the needle vertically penetrated the chest wall and thoracoscopically indicated the target site in the LAD. This point was used as the mid-point of the skin incision for a 6-cm thoracotomy (six cases) or a 33-mm access-port (four cases). Consequently, there was no conversion of approach except in the patient with pulmonary dysfunction, and each LITA-LAD anastomosis was completed directly through the mini-entry. There was no mortality and no procedure-related morbidity. Patency of each graft was confirmed within a week after surgery. After a mean follow-up period of 12.5+/-7.8 months, all of the patients except one, who died of stroke 1 year after surgery, are alive with no ischemic events. Although our experience is limited, the present video-assisted needle-guided technique can be a simple method to facilitate appropriate positioning of a mini-entry in MICAB to the LAD with a thoracoscopically prepared LITA graft.

Aged↗

Total aortic arch aneurysm repair using a stent graft without cardiac or cerebral ischemia.

A 74-year-old man with an aortic arch aneurysm and a chronic type IIIb aortic dissection underwent total aortic arch repair without cerebral or cardiac ischemia. After confirming no atheromatous change in the ascending aortic wall, a custom-designed 4-limbed graft, prepared for both arterial return of cardiopulmonary bypass and reconstruction of the arch vessels, was anastomosed onto the right side of the ascending aorta. The 3 arch vessels were then bypassed sequentially during systemic cooling and monitoring cerebral perfusion with near-infrared oxymetry. After aortic cross-clamping, a stent graft was inserted into the distal arch from the distal ascending aorta, maintaining cerebral and cardiac perfusion. This procedure is indicated especially in a high-risk patient who has an aortic arch aneurysm without severe atheromatous change in the ascending aorta and the arch vessels.

Aged↗

Conventional repair and operative stent-grafting for acute and chronic aortic dissection.

Conventional graft replacement of the ascending aorta and surgically endovascular stent-grafting of the proximal descending aorta were performed concomitantly in a 82-year-old woman with an acute DeBakey type II aortic dissection and a chronic DeBakey type IIIb aortic dissection. Postoperative computed tomography and angiography showed the adequately replaced ascending-aortic prosthesis, the well-expanded stent-graft, and the thrombosed false lumen in the descending aorta.

Acute Disease↗