PubMed Health⌕ Search

Biomedical subjects

Miklos Z Kiss

Publications and source records attributed to Miklos Z Kiss.

5 recordsLinked to original sources

Frequency-dependent complex modulus of the uterus: preliminary results.

The frequency-dependent complex moduli of human uterine tissue have been characterized. Quantification of the modulus is required for developing uterine ultrasound elastography as a viable imaging modality for diagnosing and monitoring causes for abnormal uterine bleeding and enlargement, as well assessing the integrity of uterine and cervical tissue. The complex modulus was measured in samples from hysterectomies of 24 patients ranging in age from 31 to 79 years. Measurements were done under small compressions of either 1 or 2%, at low pre-compression values (either 1 or 2%), and over a frequency range of 0.1-100 Hz. Modulus values of cervical tissue monotonically increased from approximately 30-90 kPa over the frequency range. Normal uterine tissue possessed modulus values over the same range, while leiomyomas, or uterine fibroids, exhibited values ranging from approximately 60-220 kPa.

Adult↗

Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation.

The variations in the stiffness or stiffness contrast of lesions resulting from radiofrequency (RF) ablation of canine liver tissue at different temperatures and for different ablation durations at a specified temperature are analyzed. Tissue stiffness, in general, increases with temperature; however, an anomaly exists around 80 degrees C, where the stiffness of the lesion is lower than that of the lesion ablated at 70 degrees C. On the other hand, the stiffness increases monotonically with the duration of ablation. Plots illustrating the ratio of mean strains in normal canine liver tissue to mean strains in ablated thermal lesions demonstrate the variation in the stiffness contrast of the thermal lesions. The contrast-to-noise ratio (CNRe) of the lesions, which serves as an indicator of the detectability of the lesions under the different experimental imaging conditions described above, is also presented. The results presented in this paper show that the elastographic depiction of stiffer thermal lesions is better, in terms of the CNRe parameter. An important criterion in the elastographic depiction of RF-ablated regions of tissue is the trade-off between ablation temperature and duration of ablation. Tissue necrosis can occur either by ablating tissue to high temperatures for short durations or to lower temperatures for longer durations. In this paper, we attempt to characterize the elastographic depiction of thermal lesions under these different experimental conditions. This paper provides results that may be utilized by practitioners of RF ablation to decide the ablation temperature and duration, on the basis of the strain images of normal liver tissue and ablated thermal lesions discussed in this paper.

Animals↗

Viscoelastic characterization of in vitro canine tissue.

Mechanical properties of biological tissues are of interest for assessing the performance of elastographic methods that evaluate the stiffness characteristics of tissue. The mechanical properties of interest include the frequency-dependent complex moduli, storage and loss moduli of tissues. Determination of the mechanical properties of biological tissues is often limited by proper geometry of the sample, as well as homogeneity of the stress-strain relationship. Measurements were performed on in vitro canine liver tissue specimens, over a frequency range from 0.1 to 400 Hz. Tests were conducted using an EnduraTEC ELF 3200, a dynamic testing system for determining the mechanical properties of materials. Both normal tissues and thermal lesions prepared by radio frequency ablation were tested. Experiments were conducted by uniaxially compressing tissue samples using Plexiglas platens larger than the specimens and measuring the load response. The resulting moduli spectra were then fit to a modified Kelvin-Voigt model, called the Kelvin-Voigt fractional derivative model. The data agree well with the model and in comparing the results from the normal tissue with that of the thermal lesions, the concept of a complex modulus contrast is introduced and its applications to elastography are discussed.

Animals↗

Improved image contrast of calcifications in breast tissue specimens using diffraction enhanced imaging.

The contrast of calcifications in images of breast tissue specimens using a synchrotron-based diffraction enhanced imaging (DEI) apparatus has been measured and is compared to the contrast in images acquired using a conventional synchrotron-based radiographic imaging modality. DEI is an imaging modality which derives image contrast from x-ray absorption, refraction and small-angle scatter-rejection (extinction), unlike conventional radiographic techniques, which can only derive contrast from absorption. DEI is accomplished by inserting an analyser crystal in the beam path between the sample and the detector. Two of the three breast tissue specimens contained calcifications associated with cancer, while a third contained benign calcifications. Results of the image analysis indicate that the DEI contrast of images taken with the analyser crystal tuned to the peak of its rocking curve, was as much as 19 times that of the conventional radiograph, with an average of 5.5 for all calcifications. This improved image contrast for even near-pixel-size calcifications suggests potential utility for DEI in breast imaging.

Breast Diseases↗

Measurement of image contrast using diffraction enhanced imaging.

Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Default.htm) at the Brookhaven National Laboratory. The DEI images were obtained by placing a silicon analyser crystal tuned to the [333] diffraction plane in the beam path between the sample and the detector. To compare the DEI images with conventional radiographic images requires a consistent definition of refraction and absorption contrast. Conventional definitions of contrast favour conventional radiography and DEI contrast is defined to emphasize the specific characteristics of DEI. The proposed definitions were then used to find the DEI gain (the ratio of the DEI contrast with respect to the conventional image contrast). The results presented here show that the DEI gain is consistently greater than 1, indicating that DEI provides more contrast information than conventional radiography.

Computer Simulation↗