Min Hyoung Cho

Publications and source records attributed to Min Hyoung Cho.

9 recordsLinked to original sources

In vivo trabecular thickness measurement in cancellous bones: longitudinal rat imaging studies.

Using cross-sectional x-ray images taken with zoom-in micro computed tomography (micro-CT), we have measured trabecular thickness in the femoral bones of live rats. Since zoom-in micro-CT is capable of high-resolution imaging of a small local region inside a large subject, we were able to measure trabecular thickness in femoral bones without sacrificing the rats. To longitudinally observe the trabecular thickness change caused by ovariectomy-induced osteoporosis, we have taken zoom-in micro-CT images of 15 live Sprague-Dawley rats (group A: 5 ovariectomized rats fed with regular food; group B: 5 ovariectomized rats fed with calcium-deficient food; group C: 5 controls) every other week for 10 weeks. We have observed that the mean trabecular thickness in the femoral bones of groups A and B decreased monotonically down to about 10.7% and 15.5%, respectively, as compared to that of group C, within 12 weeks after the ovariectomy, while the mean trabecular thickness of group C increased about 12.7%. We expect that zoom-in micro-CT can be successfully used in osteoporosis studies in which longitudinal imaging studies are required.

Animals↗

Observation of the fast response of a magnetic resonance signal to neuronal activity: a snail ganglia study.

We observed the response of a magnetic resonance signal to neuronal activity in dissected snail ganglia to investigate faster responding components than the blood oxygenation level dependent (BOLD) component. To eliminate the BOLD component completely from the magnetic resonance signal, we used dissected snail ganglia which have non-magnetic hemocyanin, other than hemoglobin, as an oxygen carrying protein. To activate the snail ganglia in synchronization with the magnetic resonance signal measurement, we applied 30 Hz electrical stimulation with a pulse width of 2 s to the ganglia just before the 90 degrees RF pulse. The increase of neuronal activity in the snail ganglia after the electrical stimulation was confirmed with extracellular potential recording. The magnetic resonance signal intensity, measured with the volume selection pulse sequence in a 3.0 T MRI, decreased by about 2.97 +/- 1.10% when the ganglia were activated by the electrical stimulation. We think that the MRI signal decrease is partly due to the magnetic field produced by the neuronal current and partly due to the Lorentz force exerted on the neurons when they were firing.

Animals↗

Trabecular thickness measurement in cancellous bones: postmortem rat studies with the zoom-in micro-tomography technique.

Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabecular thickness without extracting bone samples from the rats. For the zoom-in micro-tomography, we used a micro-tomography system consisting of a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector and a precision scan mechanism. To compensate for the limited spatial resolution in the zoom-in micro-tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro-tomography images, we compared the measurement results with those obtained from the conventional micro-tomography images of the extracted bone samples. The difference between the two types of measurement results was less than 2.5%.

Animals↗

X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability.

Since a micro-tomography system capable of microm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a microfocus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm(-1) suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies.

Algorithms↗

A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject holder and a parallel data processing system. The flat-panel detector is based on a matrix-addressed photodiode array fabricated by a CMOS (complementary metal-oxide semiconductor) process coupled to a CsI:T1 (thallium-doped caesium iodide) scintillator as an x-ray-to-light converter. Principal imaging performances of the micro-CT system have been evaluated in terms of image uniformity, voxel noise and spatial resolution. It has been found that the image non-uniformity mainly comes from the structural non-uniform sensitivity pattern of the flat-panel detector and the voxel noise is about 48 CT numbers at the voxel size of 100 x 100 x 200 microm3 and the air kerma of 286 mGy. When the magnification ratio is 2, the spatial resolution of the micro-CT system is about 14 1p/mm (line pairs per millimetre) that is almost determined by the flat-panel detector showing about 7 1p/mm resolving power. Through low-contrast phantom imaging studies, the minimum resolvable contrast has been found to be less than 36 CT numbers at the air kerma of 95 mGy. Some laboratory rat imaging results are presented.

Animals↗

Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography.

Magnetic resonance electrical impedance tomography (MREIT) is to provide cross-sectional images of the conductivity distribution sigma of a subject. While injecting current into the subject, we measure one component Bz of the induced magnetic flux density B = (Bx, By, Bz) using an MRI scanner. Based on the relation between (inverted delta)2 Bz and inverted delta sigma, the harmonic Bz algorithm reconstructs an image of sigma using the measured Bz data from multiple imaging slices. After we obtain sigma, we can reconstruct images of current density distributions for any given current injection method. Following the description of the harmonic Bz algorithm, this paper presents reconstructed conductivity and current density images from computer simulations and phantom experiments using four recessed electrodes injecting six different currents of 26 mA. For experimental results, we used a three-dimensional saline phantom with two polyacrylamide objects inside. We used our 0.3 T (tesla) experimental MRI scanner to measure the induced Bz. Using the harmonic Bz algorithm, we could reconstruct conductivity and current density images with 82 x 82 pixels. The pixel size was 0.6 x 0.6 mm2. The relative L2 errors of the reconstructed images were between 13.8 and 21.5% when the signal-to-noise ratio (SNR) of the corresponding MR magnitude images was about 30. The results suggest that in vitro and in vivo experimental studies with animal subjects are feasible. Further studies are requested to reduce the amount of injection current down to less than 1 mA for human subjects.

Algorithms↗

Three-dimensional forward solver and its performance analysis for magnetic resonance electrical impedance tomography (MREIT) using recessed electrodes.

In magnetic resonance electrical impedance tomography (MREIT), we try to reconstruct a cross-sectional resistivity (or conductivity) image of a subject. When we inject a current through surface electrodes, it generates a magnetic field. Using a magnetic resonance imaging (MRI) scanner, we can obtain the induced magnetic flux density from MR phase images of the subject. We use recessed electrodes to avoid undesirable artefacts near electrodes in measuring magnetic flux densities. An MREIT image reconstruction algorithm produces cross-sectional resistivity images utilizing the measured internal magnetic flux density in addition to boundary voltage data. In order to develop such an image reconstruction algorithm, we need a three-dimensional forward solver. Given injection currents as boundary conditions, the forward solver described in this paper computes voltage and current density distributions using the finite element method (FEM). Then, it calculates the magnetic flux density within the subject using the Biot-Savart law and FEM. The performance of the forward solver is analysed and found to be enough for use in MREIT for resistivity image reconstructions and also experimental designs and validations. The forward solver may find other applications where one needs to compute voltage, current density and magnetic flux density distributions all within a volume conductor.

Algorithms↗

A single current density component imaging by MRCDI without subject rotations.

Magnetic resonance current density imaging (MRCDI) is a useful method for measuring electrical current density distribution inside a subject. Due to the requirement of subject rotations in MRCDI, MRCDI has not been widely applied to in vivo studies. In this paper, we propose a new current density image (CDI) reconstruction method by which a single component of the current density can be imaged by MRCDI without subject rotations. After measuring one of the two magnetic field components, produced by the current density component passing through the measurement plane, we have reconstructed the current density component images in the spatial frequency domain. Even though the proposed method has a limitation that the area of magnetic field measurement should be much larger than that of the current density, the proposed method is expected to expedite MRCDI applications to in vivo studies.

Computer Simulation↗

J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images.

Recently, a new static resistivity image reconstruction algorithm is proposed utilizing internal current density data obtained by magnetic resonance current density imaging technique. This new imaging method is called magnetic resonance electrical impedance tomography (MREIT). The derivation and performance of J-substitution algorithm in MREIT have been reported as a new accurate and high-resolution static impedance imaging technique via computer simulation methods. In this paper, we present experimental procedures, denoising techniques, and image reconstructions using a 0.3-tesla (T) experimental MREIT system and saline phantoms. MREIT using J-substitution algorithm effectively utilizes the internal current density information resolving the problem inherent in a conventional EIT, that is, the low sensitivity of boundary measurements to any changes of internal tissue resistivity values. Resistivity images of saline phantoms show an accuracy of 6.8%-47.2% and spatial resolution of 64 x 64. Both of them can be significantly improved by using an MRI system with a better signal-to-noise ratio.

Algorithms↗