PubMed Health⌕ Search

Biomedical subjects

Minako Kawamura

Publications and source records attributed to Minako Kawamura.

2 recordsLinked to original sources

Prompt contrast enhancement of cerebrospinal fluid space in the fundus of the internal auditory canal: observations in patients with meningeal diseases on 3D-FLAIR images at 3 Tesla.

We speculated that meningeal pathologies might facilitate the permeability of cranial nerves at the fundus of the internal auditory canal (IAC), causing prompt enhancement after administration of Gd-DTPA. Using a 3D- fluid-attenuated inversion recovery (FLAIR) sequence, we evaluated the enhancement of the cerebrospinal fluid (CSF) space in the IAC fundus 10 min after Gd-DTPA administration in patients with meningeal diseases. Twenty patients (aged 22 to 79 years) were divided into 2 groups, a group with meningeal disease comprising 9 patients with meningeal abnormalities (6, tumor dissemination; 3, infection) and a control group of 11 patients with unilateral IAC pathology whose healthy sides were included as controls. Six of the 9 patients in the group with meningeal disease showed bilateral enhancement; one showed unilateral enhancement. None of the control group showed enhancement in the healthy side. One patient with Ramsay-Hunt syndrome showed only ipsilateral enhancement. Enhancement in the IAC fundus was frequently observed in patients with meningeal disease, even just 10 min after administration of contrast agent. This enhancement in the IAC fundus was never visible on T1-weighted 3D-FLASH images.

Adult↗

Analytical goals for coagulation tests based on biological variation.

Allowable imprecision and bias reference limits for laboratory data can be calculated based on measurements of biological variation. Although biological variation of clinical chemical data has been reported from many laboratories, there have been few reports of biological variation in coagulation tests. In this study, we calculated the biological variation of 13 coagulation tests in the clinical laboratory of Kyushu University Hospital and determined allowable imprecision and bias limits of variation. The participating subjects were 17 healthy individuals: three males and two females in their 20s, two males and two females in their 30s, one male and four females in their 40s, and two males and one female in their 50s. Monthly measurements were performed before breakfast 12 times from June 2001 to May 2002 and allowable imprecision and bias limits were calculated. Taken together with coefficient of variation of control plasma used in daily laboratory work at the hospital, the allowable imprecision limits of intra-laboratory variation determined in this study appear to be in attainable ranges.

Adult↗