PubMed Health⌕ Search

Biomedical subjects

Ming-Xing Xie

Publications and source records attributed to Ming-Xing Xie.

8 recordsLinked to original sources

Assessment of atrial septal defect area changes during cardiac cycle by live three-dimensional echocardiography.

OBJECTIVES: To investigate the accuracy of measurement of the atrial septal defect (ASD)area and dynamic change by live three-dimensional echocardiography (L3DE). METHODS: L3DE was performed in patients with ASD using a three-dimensional workstation to obtain the en face view of the ASD and measure its area at the peak of P-wave, the peak of R-wave, the initial and the destination point of T-wave, and the period of P-T. Parameters derived from L3DE were compared with intraoperative measurements. RESULTS: The ASD area changed significantly during cardiac cycles (mean change 46.1%, p < 0.0001; range 15.2-72.5%), with the maximal area at endsystole and the minimal area at enddiastole. There was excellent correlation between L3DE and intraoperative measurements for the area of ASD at the peak of P-wave (r = 0.92). There were good correlations between the two methods during the other phases of cardiac cycle (r = 0.81-0.86). CONCLUSIONS: L3DE provides accurate and feasible measurements of the ASD area. Investigation of the dynamic changes during the cardiac cycle may lead to an improved understanding of the hemodynamics of ASD.

Adolescent↗

Comparison of accuracy of mitral valve area in mitral stenosis by real-time, three-dimensional echocardiography versus two-dimensional echocardiography versus Doppler pressure half-time.

Mitral valve area (MVA) in 30 patients with mitral stenosis (MS) and 34 normal controls was calculated by real-time, 3-dimensional echocardiography (RT3DE); MVA in patients with MS correlated well with the mitral area determined by 2-dimensional echocardiography (r = 0.98) and by pressure half-time (r = 0.90). MVA in normal controls on RT3DE correlated well with MVA on 2-dimensional echocardiography (r = 0.94) and pressure half-time (r = 0.91). There were significant differences between the orifice areas in patients with MS and normal controls. RT3DE can provide not only the anatomic structure of mitral valve apparatus, but also the optimal plane of the smallest mitral valve orifice, and can thus accurately measure the MVA.

Adult↗

[Establishment of immunomagnetic capture-fluorescent PCR detection method for Campylobacter jejuni].

In order to develop a rapid method which can check Campylobacter jejuni in animal and poultry foods nicely, an immunomagnetic capture-fluorescent PCR (IMC-FPCR) method was established in this paper. The reported method involves isolation of the target pathogen by immunocapture prior to the fluorescent PCR step, therefore the immunomagnetic-beads for Campylobacter were developed, and two groups of primer/probe, which targeted for the species special sequence of flaA gene and hipO gene for Campylobacter jejuni were designed. The immunomagnetic capture-fluorescent PCR assay amplification of the hipO gene and flaA gene for detection of Campylobacter jejuni was firstly reported in this paper. Result indicated that IMC-FPCR method permits direct detection of the pathogen without an enrichment step and can be performed in approximately 24 h. The assay results are positive for all of the isolates of Campylobacter jejuni (3 isolates, including type strain ATCC 33560 and ATCC8341) with a detection limit of approximately 10 cfu/mL, are negative for Campylobacter coli and several other bacteria. IMC-FPCR assay provide not only a rapid, sensitive method for quantitative detection of Campylobacter jejuni, but also an important method for detecting of Campylobacter jejuni of viable but non-culturerable (VNC) state.

Campylobacter jejuni↗

Real-time 3-dimensional echocardiography in assessing atrial and ventricular septal defects: an echocardiographic-surgical correlative study.

OBJECTIVE: The aim of this study is to explore the feasibility and the value of real-time 3-dimensional echocardiography (RT3DE) in quantitative evaluation of the size of atrial septal defect (ASD) and ventricular septal defect (VSD) and to correlate with the surgical findings. METHODS: Thirty eight patients with ASD and/or VSD were examined with RT3DE. Three-dimensional image data-base was post-processed using 3D work-station. The results were compared with the results measured by 2-dimensional echocardiography and surgical findings. RESULTS: RT3DE produced novel views of congenital septal defects and improved quantification of the size of the defect. The sizes obtained from 3DE have better correlation with surgical findings than diameter measured by 2-dimensional echocardiography (r = 0.69 vs r = 0.92). CONCLUSIONS: RT3DE offers additional special information in congenital heart disease without extending examining time, permits quantitative recording of septal defect dynamics, and enhances the understanding of complex cardiac anatomy and elucidation of the disease mechanism. It is a potentially valuable clinical tool for diagnosing and managing patients with congenital heart disease.

Adolescent↗

Experimental study of quantitative assessment of left ventricular mass with contrast enhanced real-time three-dimensional echocardiography.

OBJECTIVES: To evaluate the feasibility and accuracy of measurement of left ventricular mass with intravenous contrast enhanced real-time three-dimensional (RT3D) echocardiography in the experimental setting. METHODS: RT3D echocardiography was performed in 13 open-chest mongrel dogs before and after intravenous infusion of a perfluorocarbon contrast agent. Left ventricular myocardium volume was measured according to the apical four-plane method provided by TomTec 4D cardio-View RT1.0 software, then the left ventricular mass was calculated as the myocardial volume multiplied by the relative density of myocardium. Correlative analysis and paired t-test were performed between left ventricular mass obtained from RT3D echocardiography and the anatomic measurements. RESULTS: Anatomic measurement of total left ventricular mass was 55.6 +/- 9.3 g, whereas RT3D echocardiographic calculation of left ventricular mass before and after intravenous perfluorocarbon contrast agent was 57.5 +/- 11.4 and 55.5 +/- 9.3 g, respectively. A significant correlation was observed between the RT3D echocardiographic estimates of total left ventricular mass and the corresponding anatomic measurements (r = 0.95). A strong correlation was found between RT3D echocardiographic estimates of left ventricular mass with perfluorocarbon contrast and the anatomic results (r = 0.99). Analysis of intraobserver and interobserver variability showed strong indexes of agreement in the measurement of left ventricular mass with pre and post-contrast RT3D echocardiography. CONCLUSIONS: Measurements of left ventricular mass derived from RT3D echocardiography with and without intravenous contrast showed a significant correlation with the anatomic results. Contrast enhanced RT3D echocardiography permitted better visualization of the endocardial border, which would provide a more accurate and reliable means of determining left ventricular myocardial mass in the experimental setting.

Animals↗

Live three-dimensional echocardiography: imaging principles and clinical application.

Live three-dimensional echocardiography (L3DE) is an important breakthrough in the field of medical ultrasound. It will provide a great potential tool for clinical diagnosis and treatment. In this article, the authors first review the bottlenecks in 3D cardiac imaging and the technical principles of L3DE that have been used to overcome some of these problems. We then discuss the scanning methods, clinical usefulness, and the future of L3DE, drawing on our experiences in examining 124 human patients and in conducting animal verification studies with a live 3D ultrasound system.

Echocardiography, Three-Dimensional↗

Real-time 3-dimensional echocardiography: a review of the development of the technology and its clinical application.

Real-time 3-dimensional echocardiography (RT3DE) is a new imaging technique that can provide accurate, important, and additional information concerning cardiovascular morphology, pathology, and function. This article will review the development of the technology of RT3DE and its clinical application. As the technique continues to evolve, RT3DE is bound to play an increasingly important role in the diagnosis, prognosis, and treatment of patients with various forms of cardiovascular disease.

Echocardiography, Three-Dimensional↗