[A data acquisition system for induced current electrical impedance tomography].

Induced current electrical impedance tomography (ICEIT) is a new branch of electrical impedance tomography (EIT). We have designed and set up a high accuracy ICEIT hardware system with 32 electrodes based on physical phantom, and we have brought forward a new method to reduce the additive electromotive force (EMF) in circuit of the electrode leads. By use of the technique of twisted pair wire, the additive EMF in the circuit of the electrode leads has been reduced to 10% of that before use and the precision of the system has been improved. The precision of the final results is better than 0.5% after 1000 measurement data averaged. Applying the reconstructive algorithm, we have obtained preliminary images based on physical phantom.

Algorithms↗

[An experimental system of induced-current EIT].

Induced-current electrical impedance tomography (ICEIT) is a newly hot research field in electrical impedance tomography (EIT) because of its advantages of contactless exciting. A preliminary ICEIT system with 3 excitation coils has been accomplished. It includes the constant current source (CCS), power amplifiers, excitation coils,physical phantom, measurement-mode setting circuit, signal measuring block, DAC and digital I/O card. The CCS is accomplished with Direct Digital Synthesis (DDS) technique. Its frequency is 46.875 KHz. Its output current is divided into 16 steps from 0.16 mA to 2.56 mA which can be set by computer. The three driving coils have the same diameter of 50 cm, each coil's inductance is 193.5 microH. The power amplifier can provide 800 mA driving current (f = 46.875 KHz) to the coil under +/- 25 V power supplying. The signal from measurement electrodes is switched to measurement channel which includes IA, BP filter and synchronized demodulator, then the analog signal is converted to digital signal by a 12b A/D Card and the data is acquired by DMA mode. Our experiments show that a distinguish change of signal from the surface electrodes can be acquired by the experimental system when different objects are placed in the physical phantom. And 3 x 31 signals for preliminary imaging have been acquired.

Algorithms↗

[In vivo measurement of rabbits brain impedance frequency response and the elementary imaging of EIT].

The in vivo measurements of rabbit brain tissue impedance were taken under both normal and ischemic conditions by using two-electrode measurement method in the frequency range from 0.1 Hz to 1 MHz. The dynamic images about the resistivity of cerebral ischemia were reconstructed based on a 16-electrode system. The results of in vivo measurement showed that the ratio of impedance increased can be as high as 75% at frequencies lower than 10 Hz. In the range from 1 KHz to 1 MHz, the ratio showed a constant value of 15%. The electrical impedance tomography (EIT) images obtained suggested that the regions of impedance changes highly correspond to the position of ischemia. It is confirmed that the brain function changes caused by local deficiency of blood can be detected and imaged by EIT method.

Animals↗

[The complex impedance frequency response and the equivalent circuit model of human brain].

The complex impedance measurements of human brain tissue in vitro are made by using four-electrode measurement methods in the frequency range from 0.1 Hz to 1 MHz. The Solartron 1255 B frequency response analyzer is used. The frequency response curves of the imaginary part of human brain's complex impedance do not appear as a single peak curve which other bio-tissues show, and the Cole-Cole diagram of human brain is different from the others as well. The construction of the equivalent circuit model obtained is more complex. However, these characteristics of human brain are all the same as rabbit brain's. The equivalent circuit model obtained will be helpful to constructing the equivalent circuit model of human head in the EIT researches.

Adult↗

[Simulation study of the reconstruction algorithm for electrical impedance tomography based on the sensitivity theorem].

It is the intent of this paper to develop better reconstruction algorithm for electrical impedance tomography (EIT). Simulation study of the reconstruction algorithm based on the sensitivity theorem is made and the reconstruction algorithm is compared with other normal algorithms. The results indicate that sensitivity method as a kind of static reconstruction algorithm has higher accuracy and speed of iteration, so it is worth researching for laboratory modality work.

Algorithms↗

[The impedance frequency response of the human skull].

The human skull impedance was quantitatively measured by means of Frequency Response Analyzer and its software. The impedance-frequency response curves of human skull were obtained. By analyzing the curves, we found that the characteristic frequency of human skull should be around 10 KHz.

Adult↗