PubMed Health⌕ Search

Biomedical subjects

Miodrag Filipovic

Publications and source records attributed to Miodrag Filipovic.

11 recordsLinked to original sources

Transesophageal Doppler echocardiographic detection of intramyocardial collateral flow to the right coronary artery and changes in the flow to the inferior left ventricular wall immediately after coronary artery bypass grafting.

This study examined the feasibility of Doppler transesophageal echocardiography (TEE) to detect collateral flow to the myocardium supplied by the right coronary artery (RCA) in the inferior left ventricular wall. Forty-four patients who underwent elective coronary artery bypass grafting (CABG) were prospectively studied. Presence of collateral flow to the RCA was diagnosed on preoperative angiography using the Rentrop score and by intraoperative Doppler TEE. Agreement of the 2 methods was analyzed by calculating the kappa coefficient. Collateral flow was present on preoperative angiography in 19 patients and absent in 25 patients. Intraoperative TEE detected collateral flow in the inferior wall in 15 patients (79%) with and 3 patients (12%) without angiographic collaterals, resulting in a kappa coefficient for agreement of 0.67 (95% confidence interval 0.45 to 0.90). Baseline collateral flow disappeared after CABG in 12 of 14 patients with grafting of the RCA but persisted in all patients without such grafting. Physiologic flow in the inferior wall was detected by TEE in a total of 27 patients at baseline and in 38 patients after CABG (p = 0.0018); its peak velocity increased after surgery only in the subgroup of patients with grafting of the RCA. In conclusion, these findings indicate that Doppler TEE may detect collateral flow in the inferior left ventricular wall, and that there are typical changes in collateral and physiologic flow after CABG.

Adult↗

Accuracy of tissue Doppler estimation of the right atrial pressure in anesthetized, paralyzed, and mechanically ventilated patients.

The ratio of tricuspid peak early inflow velocity to peak early diastolic velocity of the lateral tricuspid annulus (the E/Ea ratio) measured by transthoracic echocardiography has been reported to correlate with right atrial (RA) pressure. In this study, the correlation between the E/Ea ratio and RA pressure was tested in 44 anesthetized, paralyzed, and mechanically ventilated patients by transesophageal echocardiography. Mean RA pressure and the following echocardiographic data were recorded simultaneously: tricuspid peak early inflow velocities by Doppler echocardiography, peak early diastolic velocity of the lateral tricuspid annulus by tissue Doppler imaging, and right ventricular and left ventricular end-diastolic areas. Linear regression did not indicate a correlation between the E/Ea ratio and RA pressure (r = -0.11, p = 0.48) or between the E/Ea ratio and the right or left ventricular end-diastolic area index; it revealed a weak correlation between RA pressure and the inspiratory plateau pressure and body mass index. In conclusion, the E/Ea ratio failed to predict RA pressure or planimetric indexes of ventricular preload in anesthetized, paralyzed, and mechanically ventilated patients. In these patients, RA pressure was largely influenced by extracardiac factors.

Anesthesia, General↗

Long-term prognostic value of the preoperative 12-lead electrocardiogram before major noncardiac surgery in coronary artery disease.

BACKGROUND: Knowledge of the prognostic information of preoperative 12-lead electrocardiogram (ECG) recordings in patients with coronary artery disease (CAD) undergoing noncardiac surgery is limited. METHODS: The prognostic information derived from the preoperative ECGs of 172 CAD patients undergoing major noncardiac surgery was analyzed to determine its predictive value for long-term outcome. Primary end point was all-cause mortality; secondary end point was major adverse cardiac events (MACE) at 2 years. RESULTS: Prevalence of ECG abnormalities was 53% for T-wave alterations; 46% for Q waves; 38% for ST deviations; and, depending on the criterion used, 2% to 19% for left ventricular hypertrophy. During follow-up, 40 (23%) patients died and 31 (18%) had MACE. After adjustment for clinical baseline findings, including current medication with beta-blockers, ST depressions (odds ratio [OR] 4.5, 95% confidence interval [CI] 1.9-10.5) and faster heart rate (HR) (OR 1.6, 95% CI 1.1-2.4, per 10 beats per minute [bpm] increase) were independent predictors of all-cause mortality. Faster HR (OR 1.7, 95% CI 1.1-2.6, per 10-bpm increase) was also an independent predictor of MACE. The predictive value of ECG variables did not change after adjustment for occurence of perioperative ischemia. CONCLUSION: In CAD patients, the preoperative ECG contains important prognostic information and is predictive of long-term outcome independent of clinical findings and perioperative ischemia.

Aged↗

Effects of on-pump versus off-pump coronary artery bypass graft surgery on right ventricular function.

OBJECTIVES: Right ventricular dysfunction is a possible cause of cardiac failure after coronary surgery. The use of cardiopulmonary bypass is regarded as a major cause for its occurrence, and it has been postulated that performing coronary surgery without cardiopulmonary bypass might reduce ventricular dysfunction. Therefore, this prospective, randomized, controlled study tested the hypothesis that off-pump coronary surgery would better preserve right ventricular systolic and diastolic function than conventional bypass surgery. METHODS: Fifty patients scheduled for elective coronary artery bypass surgery were randomly assigned to conventional or off-pump surgery. Right ventricular function was assessed by intraoperative transesophageal echocardiography immediately before and after coronary surgery. Right ventricular ejection fraction was used as a marker of global systolic function and tricuspid early/late (atrial) ratio as a marker of the global diastolic function. Peak systolic and early diastolic velocities of the lateral tricuspid annulus were studied to assess systolic and diastolic function in the area of the right ventricular free wall. RESULTS: Surgery was completed according to randomization in 48 of 50 patients. Preoperative characteristics were similar in both groups. Intraoperative differences between the two groups included a higher volume of allogeneic blood transfusion in the conventional surgery group. At the end of surgery, global systolic right ventricular function was similarly maintained and diastolic function similarly impaired in both groups. There were no significant intergroup differences in any of the echocardiographic markers of right ventricular function. CONCLUSIONS: Off-pump surgery did not better preserve right ventricular systolic and diastolic function than did conventional coronary surgery.

Aged↗

Influence of dobutamine on the variables of systemic haemodynamics, metabolism, and intestinal perfusion after cardiopulmonary resuscitation in the rat.

BACKGROUND: Global left ventricular dysfunction after successful resuscitation from cardiac arrest may be treated successfully with dobutamine but the effects on intestinal perfusion are unknown. METHODS: In 24 male Sprague-Dawley rats ventricular fibrillation was induced. After 4 min of untreated cardiac arrest, precordial chest compression was performed for 4 min; adrenaline (epinephrine) (90 microg kg(-1)) was injected, followed by defibrillation. Return of spontaneous circulation was achieved in 18 animals, which were allocated to receive saline 0.9% (control group, n = 6), dobutamine at 5 microg kg(-1) min(-1) (n = 6) or dobutamine at 10 microg kg(-1) min(-1) (n = 6). Measurements of haemodynamic variables and intestinal tonometer P(CO2) were made before induction of ventricular fibrillation and 15, 30, 60, and 120 min postresuscitation. RESULTS: At 120 min postresuscitation, mean aortic pressure was 82 +/- 20, 104 +/- 19, and 113 +/- 15 mmHg for the control group, the dobutamine (5 microg kg(-1) min(-1)) group and the dobutamine (10 microg kg(-1) min(-1)) group (P < 0.05 for comparison of the dobutamine (10 microg kg(-1) min(-1)) group versus the control group). Respective abdominal aortic blood flow was 107 +/- 16, 133 +/- 49, and 145 +/- 18 ml min(-1) kg(-1) (P < 0.05 for comparison of the dobutamine (10 microg kg(-1) min(-1)) group versus the control group), and superior mesenteric artery blood flow was 25 +/- 9, 28 +/- 8, and 33 +/- 8 ml min(-1) kg(-1). Arterial lactate was significantly higher (P < 0.05) in the control group (2.3 +/- 0.6 mmol l(-1)) than in the dobutamine (5 microg kg(-1) min(-1)) group (1.6 +/- 0.3 mmol l(-1)) and dobutamine (10 microg kg(-1) min(-1)) group (1.5 +/- 0.3 mmol l(-1)). Tonometrically derived P(CO2) gap was highly elevated at 15 min of postresuscitation and returned to prearrest level at 120 min postresuscitation in all groups. CONCLUSIONS: Dobutamine enhances the recovery of global haemodynamic and metabolic variables early after cardiac arrest.

Animals↗

Genotyping the butyrylcholinesterase in patients with prolonged neuromuscular block after succinylcholine.

BACKGROUND: Succinylcholine remains the standard neuromuscular blocking drug for tracheal intubation in emergency situations. The short duration of action is due to its rapid hydrolytic degradation by butyrylcholinesterase (plasmacholinesterase). Multiple variants of this enzyme are known (A, F, S, H, J, K variants) with different effects on enzyme activity. This study was undertaken to evaluate the use of molecular genetic methods in patients with clinically prolonged neuromuscular block. METHODS: Nine patients with a neuromuscular block of 14 min to 5 h were selected. All four exons of the butyrylcholinesterase were amplified by polymerase chain reaction and analyzed by automated sequencing. Molecular genetic results were compared with clinical relaxation time and with biochemical test results (total butyrylcholinesterase activity, dibucaine and fluoride inhibition). RESULTS: Seven of nine patients were mutation carriers. Five of these had more than one mutation. The A and K variants were the most frequent variations. Three of four patients who were homozygous for the A variant were also carriers of the K allele. The authors identified one novel mutation (G1294T) introducing a stop codon at amino acid position 432. The duration of neuromuscular block was substantially different between patients with identical butyrylcholinesterase genotypes. CONCLUSIONS: Variations in the genetic sequence of butyrylcholinesterase are frequent in patients with prolonged duration of action of succinylcholine. Direct sequencing of the whole butyrylcholinesterase gene is an appropriate method for genotyping and, accordingly, should be used in future clinical studies with drugs metabolized by this enzyme (e.g., succinylcholine, mivacurium).

Adult↗

From the echocardiography machine to the lecture room: a simple method for transferring echocardiographic frames and loops to a personal computer.

UNLABELLED: The use of computers in scientific and educational presentations is rapidly increasing. As a digital presentation is ideal for showing moving images, the use of multimedia files, e.g., echocardiographic loops within these presentations, is common. Even though recent echocardiography machines store acquired data in a digital format, these data are often not readily accessible to be transferred to a personal computer. We present an easy and cost-efficient method for transferring frames and loops from any echocardiography machine into a personal computer using a digital video camera equipped with a standard analog input and flash memory. Still images and movies are stored in the camera to be subsequently transferred to a personal computer. In the computer, still images and movies are post-processed with graphical and video editing software. Finally, the still images and movies can be projected from the video camera or presented with specialized software such as PowerPoint. The images can also be used for Web-based publications and production of educational material or books on electronic media such as CD-ROM. The described method can also be used to transfer images from other proprietary devices and programs, as long as the devices are equipped with an analog video outlet. IMPLICATIONS: The transfer of frames and loops from echocardiographic machines to personal computers is often useful for publication, teaching, and educational purposes. We present an easy and cost-effective method for transferring frames and loops from any echocardiography machine into a personal computer using a digital video camera.

Audiovisual Aids↗

Transesophageal echocardiography for monitoring segmental wall motion during off-pump coronary artery bypass surgery.

In this prospective, observational study, we evaluated whether transesophageal echocardiography allows for monitoring left ventricular segmental wall motion during cardiac displacement for off-pump coronary artery bypass (OPCAB) surgery. On the basis of a pilot study that showed frequent loss of transgastric views during OPCAB surgery, we analyzed only midesophageal views. The midesophageal 4-chamber view, 2-chamber view, and long-axis view were recorded in 60 patients after opening the chest and placing an epicardial stabilizer on the displaced heart. Using the 16-segment model, 2 echocardiographers independently performed offline analysis of segmental wall motion. The percentage of patients in whom >or=14 left ventricular segments were readable was calculated at baseline and after cardiac displacement and placement of an epicardial stabilizer. At baseline, >or=14 segments were readable in 59 (98%) of 60 patients. After cardiac displacement, >or=14 segments were readable during 58 (76%) of 76 revascularizations of the left anterior descending coronary artery (P < 0.01 versus baseline), during 33 (83%) of 40 revascularizations of the left circumflex coronary artery (P < 0.01 versus baseline), and during 29 (94%) of 31 revascularizations of the right coronary artery (not significant). We conclude that the number of readable segments decreased after cardiac displacement but that availability of >or=14 readable segments allowed for reliable monitoring of segmental wall motion in 4 of 5 patients during OPCAB surgery.

Aged↗

Sevoflurane decreases bispectral index values more than does halothane at equal MAC multiples.

At the minimum alveolar concentration (MAC) of inhaled anesthetics, 50% of subjects move in response to noxious stimulation. Similarly, at MAC-awake, 50% of subjects respond appropriately to command. The bispectral index (BIS) nominally measures the effect of anesthetics on wakefulness or consciousness. We postulated that the use of halothane with a larger MAC-awake/MAC ratio than sevoflurane would produce higher BIS values at comparable levels of MAC. We studied 33 unpremedicated patients anesthetized by inhalation, 18 with sevoflurane and 15 with halothane. We measured BIS before and during anesthesia at 1 MAC, both before and after tracheal intubation facilitated by fentanyl and rocuronium and then at 1.5 MAC. BIS measurements were made after meeting steady-state conditions. No surgery was performed during this study. BIS values in awake patients did not differ between the sevoflurane and halothane groups (96 +/- 2 and 96 +/- 2, mean +/- sd, respectively). At 1 MAC without and with neuromuscular blockade and at 1.5 MAC, BIS values for patients anesthetized with halothane (54 +/- 7, 56 +/- 7, and 49 +/- 7, respectively) exceeded those for patients anesthetized with sevoflurane (34 +/- 6, 34 +/- 6, and 29 +/- 5, respectively) (P < 0.0001). This finding adds to other evidence indicating that BIS is drug specific.

Adult↗

Heart rate variability and cardiac troponin I are incremental and independent predictors of one-year all-cause mortality after major noncardiac surgery in patients at risk of coronary artery disease.

OBJECTIVES: The aim of this study was to determine whether perioperative measurements of heart rate variability (HRV) and cardiac troponin I (cTnI) add additional prognostic information to established risk scores for first-year mortality in patients at risk of coronary artery disease (CAD) undergoing major noncardiac surgery. BACKGROUND: In cardiac-risk patients undergoing major noncardiac surgery, the short- and long-term prognoses are mainly influenced by perioperative cardiac complications. Heart rate variability and cTnI are important prognostic markers in patients with congestive heart failure and myocardial infarction. METHODS: In a prospective study, 173 patients with CAD or at high risk of CAD undergoing major noncardiac surgery were followed up for one year. The main outcome measure was all-cause mortality. In addition to clinical parameters and established risk scores, HRV and cTnI were assessed perioperatively. RESULTS: Twenty-eight (16%) patients died within one year. Multivariate logistic regression analysis revealed three findings that were independently associated with death within the first year after surgery: the revised cardiac risk index (odds ratio 6.2 [95% confidence interval 1.6 to 25], depressed HRV before induction of anesthesia (16.2 [2.8 to 94]), and elevation of cTnI on postoperative day 1 or 2 (9.8 [3.0 to 32]). CONCLUSIONS: Depressed HRV before induction of anesthesia and elevated cTnI postoperatively are independent and powerful predictors of one-year mortality for patients at risk of CAD undergoing major noncardiac surgery and add incremental prognostic information to established risk scores that only consider preoperative information.

Aged↗