PubMed Health⌕ Search

Biomedical subjects

Mira Müller

Publications and source records attributed to Mira Müller.

3 recordsLinked to original sources

Evaluation of global and regional left ventricular function with 16-slice computed tomography, biplane cineventriculography, and two-dimensional transthoracic echocardiography: comparison with magnetic resonance imaging.

OBJECTIVES: We sought to compare left ventricular (LV) function assessed with multislice computed tomography (MSCT), biplane cineventriculography (CVG), and transthoracic echocardiography (Echo), with magnetic resonance imaging (MRI) as the reference standard. BACKGROUND: With the same data as acquired for noninvasive coronary angiography, MSCT enables registration of myocardial function. METHODS: A total of 88 patients (64 men and 24 women) underwent MSCT with 16 x 0.5 mm detector collimation, CVG, and MRI, whereas Echo was retrospectively analyzed in a subset of 30 patients. RESULTS: Regarding the ejection fraction, the agreement was significantly superior for MSCT than for CVG (+/- 10.2% vs. +/- 16.8%; p < 0.001) and Echo (+/- 11.0% vs. +/- 21.2%; p < 0.001). For the end-diastolic and end-systolic volumes, the limits of agreement with CVG (p < 0.001) and Echo (p < 0.001 and p < 0.02, respectively) were also significantly larger than with MSCT. In comparison with MSCT, CVG significantly overestimated the end-diastolic and end-systolic volumes (p < 0.001). Intraobserver analysis of MSCT yielded limits of agreement for ejection fraction (+/- 4.8%), end-diastolic volume (+/- 15.6 ml) and end-systolic volume (+/- 8.0 ml), and myocardial mass (+/- 18.2 g). The accuracy in identifying patients and myocardial segments with abnormal regional function was significantly higher with MSCT (84% and 95%) than with CVG (63% and 90%; p < 0.002 and p < 0.001), whereas MSCT and Echo were not significantly different in identifying patients with abnormal regional function. CONCLUSIONS: Our results indicate that the assessment of global and regional LV function with MSCT is more accurate than with CVG, whereas MSCT is superior to Echo for global function. This suggests that MSCT allows reliable evaluation of global and regional LV function.

Aged↗

Multisegment and halfscan reconstruction of 16-slice computed tomography for assessment of regional and global left ventricular myocardial function.

RATIONALE AND OBJECTIVES: We sought to prospectively compare multisegment and halfscan reconstruction of 16-slice computed tomography (CT) for the assessment of regional and global left ventricular myocardial function with magnetic resonance imaging (MRI) as the reference standard. MATERIALS AND METHODS: Forty-two patients underwent CT with 16 x 0.5-mm detector collimation. Electrocardiogram-gated reconstructions were generated with multisegment reconstruction (using up to 4 segments correlated with the raw data of up to 4 heartbeats) and standard halfscan reconstruction. Steady-state free-precession cine MRI was acquired within 24 hours. RESULTS: More normal myocardial segments were identified correctly with multisegment (95%, 620/656) compared with halfscan reconstruction (88%, 582/656) of CT (P < 0.001). Also, the accuracy (92% [657/714] vs. 87% [620/714]) and rate of nondiagnostic segments (0% vs. 5% [33/714]) were significantly better when using multisegment reconstruction (P < 0.001). The image quality with multisegment reconstruction was significantly superior to that achieved with halfscan reconstruction (P < 0.001). In the assessment of global left ventricular function, multisegment and halfscan reconstruction of CT showed high correlations for all parameters with MRI, whereas Bland-Altman analysis revealed smaller limits of agreement for assessment of myocardial mass with multisegment reconstruction (P = 0.025), but no significant differences between both reconstruction techniques in the measurement of left ventricular volumes as compared with MRI. CONCLUSIONS: Multisegment reconstruction of 16-detector row CT improves image quality and assessment of regional wall motion compared with standard halfscan reconstruction.

Adult↗

Evaluation of a semiautomatic software tool for left ventricular function analysis with 16-slice computed tomography.

The purpose of the study was to evaluate a semiautomatic analysis tool for assessing global left ventricular myocardial function with multislice computed tomography (MSCT). We examined 33 patients with MSCT using 16x0.5 mm detector collimation and magnetic resonance imaging (MRI) on a 1.5-T scanner. MSCT data were analyzed using semiautomatic volumetric analysis software (ANET, CSCF-001A, Toshiba). This software tool automatically creates endo- and epicardial contours that can be manually corrected on all short-axis slices at all reconstructed time points within the cardiac cycle, based on a contour-detection and density-threshold algorithm. All global left ventricular function parameters assessed with the semiautomatic MSCT software were highly correlated with the results of MRI. Bland-Altman analysis showed minor systematic overestimation of end-diastolic (10.7 ml) and end-systolic volumes (5.6 ml) and underestimation of ejection fraction (2.1%) with MSCT as compared with MRI. The post-processing time was moderately but significantly longer with the MSCT software (15.9+/-2.8 min) than necessary for MRI (14.0+/-2.5 min, P<0.01), mainly as a result of the longer time required for uploading of the MSCT datasets, which were on average 54 times larger (1.3 GByte). In conclusion, it appears feasible to accurately assess global left ventricular function with MSCT in a reasonable post-processing time using a semiautomatic software tool.

Contrast Media↗