Stable top-up operation at SPring-8.

Top-up operation allows SPring-8 to provide highly stable X-ray beams with arbitrary filling patterns. The implementation of top-up operation is described, with a focus on the simultaneous achievement of stability of stored current, beam orbit, purity of an isolated single bunch, and beam injection efficiency. Stored-current fluctuations have been routinely reduced to a level of 10(-3). Stored-beam oscillation on frequent beam injection, which was originally regarded as the most serious problem, has been successfully suppressed to a sufficiently low level that it never perturbs imaging experiments. Current impurities in nominally empty buckets have been reduced to a level of 10(-9) over more than one week of operation, making possible the measurement of time-resolved spectra using high-current bunches. Finally, excellent injection efficiency, higher than 80%, is routinely obtained, even for small undulator gaps, which is critical for preventing radiation damage to insertion-device magnets and to reduce leakage radiation. The process of achieving highly stabilized top-up operation at SPring-8 and its utility for user experiments are described.

Electrons↗

Two-dimensional visible synchrotron light interferometry for transverse beam-profile measurement at the SPring-8 storage ring.

A two-dimensional visible synchrotron light interferometer has been developed to measure the transverse profile of an electron beam at the SPring-8 storage ring. The new interferometer enables the simultaneous measurement of beam sizes along the major and minor axes and the beam-tilt angle of an assumed elliptical Gaussian distribution. The principle of the interferometer is explained through basic formulae. To calibrate the point-spread function of the interferometer, a simple error model was assumed for disturbances in the amplitude and phase of the light; these disturbances were presumably caused by optical elements, such as mirrors and lenses. The experimental method to determine the parameters in the error model is shown. To verify the two-dimensional profiling capabilities of the interferometer, an electron beam stored in the SPring-8 storage ring operated at various working points was observed. A beam broadening from 20 to 120 microm in the vertical direction and changes in the beam-tilt angle were clearly observed at working points close to the differential resonance. However, the vertical spatial resolution is limited by the available vertical separation of the apertures of the diffracting mask because of the narrow aperture of the upstream vacuum duct.

Journal Article↗