PubMed Health⌕ Search

Biomedical subjects

Mitsuhiro Wada

Publications and source records attributed to Mitsuhiro Wada.

30 records · Page 2Linked to original sources

Rapid separation of barbiturates and benzodiazepines by capillary electrochromatography with 3-(1,8-naphthalimido)propyl-modified silyl silica gel.

A capillary electrochromatographic (CEC) method was applied to the simultaneous separation of barbiturates (barbital, phenobarbital, secobarbital and thiopental) and benzodiazepines (nitrazepam, diazepam and triazolam). The separation was performed in a 75 microm i.d. capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effects of buffer pH and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 45% methanol provided the baseline separation of seven toxic drugs in less than 9 min. In CEC with NAIP, the benzodiazepines were separated by the combination of hydrophobic and pi-pi interactions, whereas the separation of the barbiturates was based on the hydrophobic interaction.

Barbiturates↗

Capillary electrochromatographic analysis of barbiturates in serum.

A capillary electrochromatographic method was developed for the separation of barbiturates. The separation was optimized in a 75 microm ID capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effect of buffer pH, buffer concentration, and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 40% methanol provided the baseline separation of barbital, phenobarbital, secobarbital, and thiopental (internal standard) in less than 4.5 min. The method was successfully applied to the analysis of barbiturates in human serum. Under the optimal conditions, good repeatability and linearity were obtained in the range of 2.90-43.29 microg/mL for barbital, phenobarbital, and secobarbital.

Barbiturates↗

Investigation of the novel mixed-mode stationary phase for capillary electrochromatography. II. Separation of amino acids and peptides on sulfonated naphthalimido-modified silyl silica gel.

The potential of 3-(4-sulfo-1,8-naphthalimido)propyl-modified silyl silica gel (SNAIP) as a mixed-mode stationary phase for capillary electrochromatography (CEC) was investigated for the separation of charged analytes, taking four amino acids (tyrosine, phenylalanine, tryptophan, histidine) as model analytes. The elution process of these charged analytes in CEC with SNAIP was dominated by a combination of both electrophoretic process and chromatographic process involving hydrophobic as well as electrostatic interactions. In order to study the retention mechanism, the CEC retention factor k* and the velocity factor ke* were measured for the amino acids, which allowed the assessment of the respective contribution from the differential processes underlying the separation. Migration and retention could be mediated by changing various mobile phase compositions, including buffer pH, buffer concentration, and concentration of organic solvent. Based on the results obtained by separation of the amino acids, the separation of eight peptides (Gly-Val, Gly-Phe, Gly-Ile, Gly-His, Gly-Lys, Lys-Lys, Gly-Gly-Gly, Gly-Gly-His) was attempted. A good separation was achieved under an isocratic elution with a mobile phase consisting of 35 mM phosphate buffer (pH 3.8) and 40% methanol.

Amino Acids↗

Pharmacokinetic interactions between phenylpropanolamine, caffeine and chlorpheniramine in rats.

As the mechanism involved in the serious adverse effects associated with phenylpropanolamine (PPA) has not yet been clarified, and as PPA in usual cases is not being ingested without other drugs combination, the aim of this study was to characterize the possibility of pharmacokinetic interactions between PPA and most often combined drugs existing in the same dosage. The pharmacokinetics of PPA in rat brain and blood were evaluated when administered alone (group I), combined with caffeine (group II), combined with chlorpheniramine (group III), combined with both caffeine and chlorpheniramine (group IV) and finally when existed in one of the available OTC products (group V). This product contains multiple ingredients of PPA, caffeine and chlorpheniramine. In brain the pharmacokinetic parameters of PPA were significantly affected with the combined administration of caffeine and/or chlorpheniramine. The single intraperitoneal administration of caffeine (5 mg/kg) with PPA (2.5 mg/kg) to rats caused 1.6-fold increase in the AUC of PPA in brain compared to the single administration of PPA, and was comparable to the 1.5-fold increase caused by chlorpheniramine (0.4 mg/kg). The multiple combinations caused an increase in the AUC by 1.9-fold, which is comparable to the increase in the AUC of PPA obtained from the OTC product (2.2-fold). On the other hand, there was no significant difference in the pharmacokinetics of PPA in blood between the groups except for the C(max) of PPA in groups I and IV. The observed adverse effects associated with PPA use could be related to the significant increase in its levels in the brain.

Animals↗

Determination of hydroxylated polycyclic aromatic hydrocarbons in airborne particulates by high-performance liquid chromatography with fluorescence detection.

This paper describes a highly sensitive and selective method for the determination of hydroxylated polycyclic aromatic hydrocarbons (PAHs-OH) in airborne particulates. PAHs-OH were extracted from airborne particulates with ethanol by ultrasonication. The extractant was further cleaned up by solid phase extraction (SPE) with an aminopropylsilica cartridge, and subsequently analyzed by reversed-phase high-performance liquid chromatography with fluorescence detection. 2-Hydroxy-1-acetonaphthone was used as an internal standard. By the proposed method, 2-hydroxyfluorene and 1-hydroxypyrene were identified in airborne particulates and their concentrations were determined for the first time.

Journal Article↗

Determination of polycyclic aromatic hydrocarbons in milk samples by high-performance liquid chromatography with fluorescence detection.

This paper describes a high-performance liquid chromatographic (HPLC) method for the determination of polycyclic aromatic hydrocarbons (PAHs) in milk samples. The method involves a liquid-liquid extraction procedure after saponification of milk samples with sodium hydroxide. Reproducible determination with highly sensitive detection was attained by HPLC with fluorescence detection using 1,2-bis(9-anthryl)ethane as an internal standard. The detection limits of 12 kinds of PAHs ranged from 1.3 to 76 ng/kg milk at a signal/noise ratio of 3. By the proposed method, the presence of 12 and 11 kinds of PAHs could be confirmed in commercial milk and human milk samples, respectively. The average concentrations of total PAHs (mean+/-SD, micro g/kg) were found to be 0.99+/-0.37 for commercial milk (n=14), 2.01+/-0.30 for infant formula (n=3) and 0.75+/-0.47 for human milk (n=51). High correlation coefficients between the concentrations of total PAHs and triglyceride were observed for commercial milk (r=0.659) and human milk (r=0.645).

Animals↗

Determination of organic peroxides by liquid chromatography with on-line post-column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

A HPLC method was developed for the simultaneous determination of organic peroxides and hydrogen peroxide with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Organic peroxides [i.e., benzoyl peroxide (BP), tert.-butyl hydroperoxide (BHP), tert.-butyl perbenzoate (BPB), cumene hydroperoxide (CHP)] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide, which was determined by PO-CL detection. The conditions for UV irradiation and PO-CL detection were optimized by a flow injection analysis (FIA) system. Generation of hydrogen peroxide from peroxides with on-line UV irradiation also was confirmed by the FIA system by incorporating an enzyme column reactor immobilized with catalase. The separation of four organic peroxides and hydrogen peroxide by HPLC was accomplished isocratically on an ODS column within 30 min. The detection limits (signal-to-noise ratio=3) were 1.1 microM for hydrogen peroxide, 6.8 microM for BP, 31.3 microM for BHP, 7.5 microM for BPB and 1.3 microM for CHP. The proposed method was applied to the determination of BP in wheat flour.

Calibration↗

Measurement of bisphenol A levels in human blood serum and ascitic fluid by HPLC using a fluorescent labeling reagent.

A sensitive column-switching HPLC method with fluorescence detection was developed for the determination of bisphenol A (BPA) in human blood serum and ascitic fluid samples. 4-(4,5-Diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) was used as the fluorescent label, and the excess reagent was removed by a column-switching technique. Liquid-liquid extraction with chloroform was used for the pretreatment of serum and ascitic fluid samples. BPA in both the samples could be determined in the concentration range of 0.1-7.0 ppb with the detection limit of 0.04 ppb at a signal-to-noise ratio of 3. The recoveries of BPA spiked to serum and ascitic fluid were 78.6 and 77.7%, respectively. The mean concentrations of BPA (n=9) in maternal and umbilical cord blood sera obtained from healthy pregnant women were 0.46+/-0.20 and 0.62+/-0.13 ppb, respectively. BPA levels (n=21) in blood sera and ascitic fluid obtained from the patients with sterility were also determined to be 0.46+/-0.20 and 0.56+/-0.19 ppb, respectively. Relationships of BPA concentrations were observed between maternal and umbilical cord blood serum samples (r=0.626), as well as blood serum and ascitic fluid samples (r=0.785).

Ascitic Fluid↗

A simple HPLC-fluorescence detection of nitric oxide in cultivated plant cells by in situ derivatization with 2,3-diaminonaphthalene.

An HPLC method with fluorescence detection for the determination of nitric oxide (NO) in cultivated plant cells (Agave pacifica, Agavaceae) was developed. NO was derivatized in situ with 2,3-diaminonaphthalene (DAN) as a labeling reagent and converted to 1(H)-naphthotriazole. The maximum peak height of the derivative was observed by incubation for 3 h at 25 degrees C with 0.2 mM DAN. Excess reagent in cells was removed by washing 3 times with 5 ml of water. The calibration curve for authentic standard of DAN-NO spiked to cultivated plant cells showed a good linearity (r = 0.995) in the range of 5.0 to 50 pmol/g cell. The detection limit at a signal-to-noise ratio of 3 was 3.4 pmol/g cells. The proposed method was successfully applied to the monitoring of NO concentration with cell growth. The effect of thermal treatment on the concentration of NO in plant cells was also examined. The concentration of NO in cells treated at 5 degrees C for 1 h was significantly higher than that treated at 25 degrees C and 35 degrees C for 1 h (n = 3, p < 0.05).

2-Naphthylamine↗

Determination of MDMA and MDA in rat urine by semi-micro column HPLC-fluorescence detection with DBD-F and their monitoring after MDMA administration to rat.

A simultaneous semi-micro column HPLC method with fluorescence detection of abused drugs, such as 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), amphetamine (AP) and methamphetamine (MP) in rat urine was examined by using 4-(N,N-dimethylaminosulphonyl)-7-fluoro-1,2,3-benzoxadiazole (DBD-F) as a labelling reagent and alpha-phenylethylamine as an internal standard (IS). A sample (50 microL) of rat urine was added to 5 microL IS and 100 microL 100 mmol/L borate buffer (pH 12) and extracted with 1.5 mL n-hexane. After evaporation, 50 microL 75 mmol/L borate buffer (pH 8.5) and 50 microL 20 mmol/L DBD-F in CH3CN were added to the residue and mixed well. The resultant solution was heated for 20 min at 80 degrees C and then cooled in an ice bath. A good separation of DBD-derivatives could be achieved within 45 min using a semi-micro ODS column with an eluent of CH3CN/CH3OH/10 mmol/L imidazole-HNO3 buffer (pH 7.0) (= 45:5:50, v/v/v %). The DBD derivatives were monitored at 565 nm with an excitation at 470 nm. The calibration curves showed good linearity (r = 0.997) with 0.5-15 ng/mL detection limits at a S/N ratio of 3. MDMA and MDA in rat urine could be monitored for 15 h after a single administration of MDMA to rat (2.0 mg/kg, i.p.). The concentrations for MDMA and MDA (n = 3) were 0.13-160.1 and 0.17-10.9 microg/mL, respectively.

3,4-Methylenedioxyamphetamine↗

Pentazocine monitoring in rat hair and plasma by HPLC-fluorescence detection with DIB-Cl as a labelling reagent.

Pentazocine (PZ) in rat hair and plasma was determined by HPLC-fluorescence detection with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) as a labelling reagent and cyclazocine (CZ) as an internal standard (IS). PZ and IS extracted from hair or plasma sample were derivatized with DIB-Cl and the resulted solution was cleaned up with solid phase extraction. The isocratic separation of DIB-PZ and -CZ within 20 min could be achieved by a Wakopak Handy-ODS column (250 x 4.6 mm i.d.) using a mobile phase composed of 0.1 mol/L acetate buffer (pH 6.2):acetonitrile (25:75, v/v). The detection limits of PZ at a signal-to-noise ratio of 3 for rat hair and plasma were 0.18 ng/mg and 0.57 ng/mL, respectively. Reproducible and precise results could be obtained by an IS method with RSD values less than 6.6% for within- and between-day measurements. The method was successfully applied for the monitoring of PZ levels in Zucker rat hair and plasma samples after a single administration of 25 mg/kg PZ. Moreover, incorporation rates of PZ into black and white hair of Zucker rat were evaluated.

Animals↗

Quantification of MDMA and MDA in abusers' hair samples by semi-micro column HPLC with fluorescence detection.

A sensitive semi-micro column high-performance liquid chromatography with fluorescence detection method was developed for the determination of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), methamphetamine (MP) and amphetamine (AP) in human hair. 4-(4,5-Diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl) and 1-methyl-3-phenylpropylamine were used as labeling reagent and internal standard, respectively. These drugs were extracted from hair into 5% trifluoroacetic acid in methanol, and fluorescent labeled with DIB-Cl. The separation of DIB-derivatives was achieved on a reversed-phase semi-micro ODS column with an acetonitrile-methanol-water (30:40:30, v/v/v%) mixture as a mobile phase. The limits of detection at a signal-to-noise ratio of 3 for MDMA, MDA, MP and AP were 0.25, 0.15, 0.25 and 0.19 ng/mg, respectively. Precision of intra- and inter-day assay as the relative standard deviation were in the range 1.5-6.8% (n = 5) and 2.7-4.7% (n = 5), respectively. The proposed method was highly sensitive and able to detect MDMA and its related compounds in small amounts of hair sample, and could be applied to quantification of six abusers' hair samples.

3,4-Methylenedioxyamphetamine↗