Radial GRASE: implementation and applications.

RAD-GRASE is an MRI sequence that combines radial (RAD) k-space scanning with the gradient and spin-echo (GRASE) technique. RAD-GRASE has the advantages of all radial data acquisition methods in that it can reduce motion sensitivity and correct motion-induced data errors, which can be exploited to achieve high-resolution diffusion-weighted imaging (DWI). One can obtain different types of image contrast, including DWI, T(1), T(2), and T(2)*, in RAD-GRASE by controlling the magnetization preparation and sequence timing. Moreover, because there is oversampling of the low spatial frequencies inherent to radial sequences, partial data reconstruction can be used to achieve multiple forms of image contrast from a single acquired data set, and to generate parametric image maps of equilibrium magnetization, T(2), and T(2) (dagger). The RAD-GRASE technique can also be used to achieve fat-suppressed and/or separated fat and water images by choosing the appropriate timing parameters.

Abdomen↗

Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver.

PURPOSE: To evaluate a multishot radial fast-spin echo (RAD-FSE) method developed to improve the quality of abdominal T2-weighted imaging as well as the characterization of focal liver lesions. MATERIALS AND METHODS: The RAD-FSE sequence used in this work consisted of a preparatory period followed by a short echo train (ETL = 16). A novel radial k-space trajectory was used to minimize streaking artifacts due to T2 variations and motion. Small diffusion gradients (b = 1.2 mm/s(2)) were used to improve flow suppression. The quality of images obtained with RAD-FSE was compared to multishot 2DFT fast spin-echo (2DFT-FSE) and half-Fourier acquisition single-shot turbo-spin-echo (HASTE) images using data from 16 patients. A postprocessing algorithm was used to generate multiple high-resolution images (at different effective TE values) as well as a T2 map from a single RAD-FSE data set. The T2 maps were used to differentiate malignant from benign lesions for a set of 33 lesions ranging from 0.8-194 cm(3). RESULTS: RAD-FSE produces high-resolution images of the liver in a breath-hold without the motion artifacts of 2DFT-FSE methods, and without the blurriness and loss of small lesion detectability of HASTE. The inclusion of diffusion weighting in RAD-FSE decreases the signal from blood in hepatic vessels, which improves lesion visualization. The T2 values obtained by postprocessing a single RAD-FSE data set can differentiate malignant from benign lesions. The mean T2 values obtained for malignancies, hemangiomas, and cysts are 108 +/- 30 msec, 240 +/- 14 msec, and 572 +/- 334 msec, respectively. CONCLUSION: These results indicate that RAD-FSE produces abdominal images of higher quality than 2DFT-FSE and HASTE. In addition, lesions can be characterized using T2 maps generated from a single RAD-FSE data set.

Adolescent↗