Methylene blue treatment for methemoglobinemia and subsequent dramatic bispectral index reduction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Moeen K Panni.
Explore the source record for details and available documents.
In this study, we sought to determine whether there is a significant discrepancy among a group of practitioners when rating pregnant patients using the ASA Physical Status Classification and whether this discrepancy could be resolved with the addition of a modifier for pregnancy. Our results indicate that significant discrepancy occurs and that it is reduced with the use of the modifier, especially when referring to the healthy parturient.
Explore the source record for details and available documents.
BACKGROUND: Dystocia is characterized by abnormal progress of labor and is a common contemporary indication for cesarean delivery in the United States. There has been considerable controversy as to whether epidural analgesia causes dysfunctional labor leading to cesarean delivery for dystocia. The minimum local analgesic concentration (MLAC) is a clinical model used to determine the relative potencies of local anesthetics in the first stage of labor. In this article, the authors report a prospective study determining the MLAC of bupivacaine in early labor of parturients who eventually delivered either vaginally or via cesarean section. METHODS: An up-down sequential allocation technique was used to determine the MLAC of bupivacaine in 57 nulliparous parturients assigned to either vaginal delivery or cesarean section arms. In addition, patients were assigned to groups receiving or not receiving intravenous oxytocin at the time of epidural placement. Only patients who delivered by the assigned delivery mode were included in the MLAC analyses. RESULTS: Parturients who later delivered vaginally had 25% and 31% lower MLAC values (0.078% and 0.085% wt/vol bupivacaine, receiving or not receiving intravenous oxytocin, respectively) than those who later delivered by cesarean section (0.102% and 0.106% wt/vol bupivacaine, receiving or not receiving intravenous oxytocin, respectively). CONCLUSIONS: These data suggest that an increased local anesthetic requirement for epidural labor analgesia is associated with more intense pain related to dystocia. Women in early, clinically normal labor but who later develop dystocia require more local anesthetic and, by inference, are experiencing more severe pain than women who deliver vaginally. This association should be considered when studying the relation between the method of labor analgesia and the course of labor.
PURPOSE OF REVIEW: The use of inhalation general anesthetic gases has led to contamination of the operating room environment. Chronic exposure to these agents has been associated with a number of adverse health effects. Controversy remains with regard to these health effects, and whether further reducing the level of operating room contamination should be a high priority. Current methods are outlined by which anesthetic waste gases contaminate and are removed from the operating room. These controversies are explored in the light of recent research. RECENT FINDINGS: Recent work employing genotoxicity studies suggests that National Institute for Occupational Safety and Health recommendations may be appropriate to protect healthcare workers. New developments over the past year include the suggestion of employing devices such as the Anesthetic Scavenging Hood (ASH), SiBI tube connector and mask stopper. The use of these devices, in concert with efficient anesthesia machine scavenging, may further reduce operating room contamination. SUMMARY: The National Institute for Occupational Safety and Health calls for lower levels of exposure when compared with those found in European standards. It may be appropriate for European guidelines to be re-addressed; however, more conclusive studies need to be undertaken to identify the precise effects of these agents at a given exposure level. It may also be appropriate to expand the arena of monitoring and scavenging to all areas where inhalation anesthetics are used or emitted, such as in the post-anesthesia care unit and research laboratory settings.
UNLABELLED: We used the epidural technique "loss of resistance to air" to provide labor analgesia in a healthy parturient. Inadequate analgesia required epidural catheter replacement using the same technique. Delayed recovery of sensory and motor blockade postpartum necessitated computed tomography and magnetic resonance imaging studies. These revealed 4-6 mL of air in the epidural space with no evidence of thecal compression. On the advice of the neurologist, this patient underwent hyperbaric therapy 14 h after the discontinuation of the epidural infusion. The patient made a complete recovery and was discharged without neurologic sequelae. It is possible that epidural air delayed the absorption of local anesthetics as a result of a reduction in the vascular surface area. Although a cause and effect relationship between epidural air and prolonged neurological block cannot be categorically established, the use of "loss of resistance to air" technique complicated the differential diagnosis. IMPLICATIONS: We report a case of prolonged motor and sensory block after labor analgesia using "loss of resistance to air" technique. The presence of epidural air on tomography resulted in the patient undergoing hyperbaric therapy. The use of loss of resistance to air technique complicated the differential diagnosis of prolonged sensory and motor block.
IMPLICATIONS: Many devices serve as portable systems for IV equipment but are expensive and use complex electronic controls. We present a novel device to facilitate safe ambulation of IV-dependent patients. This device was effective in delivering required therapeutic flow rates over time periods desired for unattended operation.
UNLABELLED: Numerous studies have suggested that chronic exposure to trace levels of anesthetic gas is harmful to operating room (OR) personnel. In the delivery of pediatric general anesthesia, an uncuffed endotracheal tube (ETT) is normally used which can result in considerable volatile anesthetic and nitrous oxide contamination of the OR. In this report, we present a method to reduce exposure to these anesthetic gases by means of an anesthetic scavenging hood (ASH). The ASH was used on six pediatric patients undergoing general endotracheal anesthesia via an uncuffed ETT. Measurements of all ambient gas levels were made 6 in. horizontally from the patient's ear and 6 in. from the table surface. The application of the vacuum source to the ASH resulted in a very significant (P < 0.01, paired t-test) decrease in levels of ambient anesthetic gas, with no measurable change in ventilatory variables or changes in body temperature (P > 0.05, paired t-test). Discontinuation of the vacuum force to the ASH resulted in a marked increase in ambient levels of anesthetic gas. We conclude that the ASH is extremely effective in reducing waste anesthetic gas associated with anesthesia administered via an uncuffed ETT. The ASH may be a valuable and cost-effective addition in the OR for both reducing ambient anesthetic waste gas levels and conserving patient heat. IMPLICATIONS: Chronic exposure to trace levels of anesthetic gas is harmful to operating room personnel, especially in the delivery of pediatric general anesthesia via an uncuffed endotracheal tube. The anesthetic scavenging hood is a cost-effective and efficient method to reduce these waste anesthetic gases, and it offers patient heat conservation.