PubMed Health⌕ Search

Biomedical subjects

Mohamed N Rahaman

Publications and source records attributed to Mohamed N Rahaman.

5 recordsLinked to original sources

The significance of metal staining on alumina femoral heads in total hip arthroplasty.

Metallic transfer to alumina can occur intraoperatively and while reducing a dislocated total hip, when the femoral head contacts the rim of the metal acetabular shell. To see if metal discoloration is associated with changes to the alumina, we examined 14 metal-stained alumina femoral heads retrieved from ceramic-on-ceramic articulations using electron microscopy and noncontact profilometry. Metal staining was associated with surface damage to alumina on the femoral heads removed from unstable total hips. The surface roughness of metal-stained alumina heads was significantly greater than that of unused alumina heads. Alumina femoral heads should be protected against contact with the metal cup during total hip implantation. Dislocations in ceramic-on-ceramic total hips should be addressed early because of possible damage to the surface.

Acetabulum↗

Kinetics and mechanisms of the conversion of silicate (45S5), borate, and borosilicate glasses to hydroxyapatite in dilute phosphate solutions.

Bioactive glasses with controllable conversion rates to hydroxyapatite (HA) may provide a novel class of scaffold materials for bone tissue engineering. The objective of the present work was to comprehensively characterize the conversion of a silicate bioactive glass (45S5), a borate glass, and two intermediate borosilicate glass compositions to HA in a dilute phosphate solution at 37 degrees Celsius. The borate glass and the borosilicate glasses were derived from the 45S5 glass by fully or partially replacing the SiO(2) with B(2)O(3). Higher B(2)O(3) content produced a more rapid conversion of the glass to HA and a lower pH value of the phosphate solution. Whereas the borate glass was fully converted to HA in less than 4 days, the silicate (45S5) and borosilicate compositions were only partially converted even after 70 days, and contained residual SiO(2) in a Na-depleted core. The concentration of Na(+) in the phosphate solution increased with reaction time whereas the PO(4) (3-) concentration decreased, both reaching final limiting values at a rate that increased with the B(2)O(3) content of the glass. However, the Ca(2+) concentration in the solution remained low, below the detection limit of atomic absorption, throughout the reaction. Immersion of the glasses in a mixed solution of K(2)HPO(4) and K(2)CO(3) produced a carbonate-substituted HA but the presence of the K(2)CO(3) had little effect on the kinetics of conversion to HA. The kinetics and mechanisms of the conversion process of the four glasses to HA are compared and used to develop a model for the process.

Borates↗

Preparation of hollow hydroxyapatite microspheres.

The preparation of hollow hydroxyapatite (HA) microspheres as potential drug-delivery vehicles was investigated. A lithium-calcium-borate (10Li(2)O-15CaO-75B(2)O(3)) (mol%) glass, made by fusing the components at 1100 degrees C for 1 h, was ground to a powder and passed through a flame at approximately 1400 degrees Celsius to spheroidize the particles. The resulting glass microspheres (106-125 microm in diameter) were reacted in 0.25 M K(2)HPO(4) solution for 5 days at 37 degrees Celsius and pH 10-12, resulting in the formation of porous, hollow microspheres of a calcium phosphate (Ca-P) material with external diameters similar to those of the original glass particles. Heat treatment at 600 degrees Celsius for 4 h partially converted the Ca-P material to HA, as confirmed by X-ray diffraction, and also increased the strength of the hollow microspheres.

Borates↗

Stem cell-based composite tissue constructs for regenerative medicine.

A major task of contemporary medicine and dentistry is restoration of human tissues and organs lost to diseases and trauma. A decade-long intense effort in tissue engineering has provided the proof of concept for cell-based replacement of a number of individual tissues such as the skin, cartilage, and bone. Recent work in stem cell-based in vivo restoration of multiple tissue phenotypes by composite tissue constructs such as osteochondral and fibro-osseous grafts has demonstrated probable clues for bioengineered replacement of complex anatomical structures consisting of multiple cell lineages such as the synovial joint condyle, tendon-bone complex, bone-ligament junction, and the periodontium. Of greater significance is a tangible contribution by current attempts to restore the structure and function of multitissue structures using cell-based composite tissue constructs to the understanding of ultimate biological restoration of complex organs such as the kidney or liver. The present review focuses on recent advances in stem cell-based composite tissue constructs and attempts to outline challenges for the manipulation of stem cells in tailored biomaterials in alignment with approaches potentially utilizable in regenerative medicine of human tissues and organs.

Animals↗

Comparison of the response of primary human blood monocytes and the U937 human monocytic cell line to two different sizes of alumina ceramic particles.

It is well recognized that wear particles derived from orthopaedic implants have the potential to induce inflammation, which may eventually lead to aseptic loosening of the artificial joint. We hypothesized that alumina ceramic particles of different sizes cause a differential cytokine response by human monocytes. To test this hypothesis a human monocytic cell line (U937) and primary human blood monocytes obtained from healthy volunteers were exposed to ceramic particles within the range known to be generated in vivo. Cellular responses were measured by quantifying the relative gene expression of 12 different cytokines using TAQman Real-Time Polymerase Chain Reaction (RT-PCR). Our results demonstrate that at a particle to cell ratio of 100:1, 0.5 microm ceramic particles consistently provoked higher amounts of Interleukin-1alpha (IL-1alpha), IL-1beta, IL-8, IL-10 and Tumor necrosis factor-alpha (TNF-alpha) steady state mRNA by U937 cells. As expected, the variability of cytokine expression in primary blood monocytes was much higher compared to the cell line however, a similar trend was observed. These results show a differential response to ceramic particle size, which may imply that 0.5 microm particles are less biocompatible. New ceramic implants can be designed to generate a known particle size range in vivo. Implant materials of this type may induce relatively lower levels of production of inflammatory cytokines resulting in a reduced incidence of failure due to aseptic loosening.

Aluminum↗