PubMed Health⌕ Search

Biomedical subjects

Mohammad-Reza Siadat

Publications and source records attributed to Mohammad-Reza Siadat.

3 recordsLinked to original sources

Content-based image database system for epilepsy.

We have designed and implemented a human brain multi-modality database system with content-based image management, navigation and retrieval support for epilepsy. The system consists of several modules including a database backbone, brain structure identification and localization, segmentation, registration, visual feature extraction, clustering/classification and query modules. Our newly developed anatomical landmark localization and brain structure identification method facilitates navigation through an image data and extracts useful information for segmentation, registration and query modules. The database stores T1-, T2-weighted and FLAIR MRI and ictal/interictal SPECT modalities with associated clinical data. We confine the visual feature extractors within anatomical structures to support semantically rich content-based procedures. The proposed system serves as a research tool to evaluate a vast number of hypotheses regarding the condition such as resection of the hippocampus with a relatively small volume and high average signal intensity on FLAIR. Once the database is populated, using data mining tools, partially invisible correlations between different modalities of data, modeled in database schema, can be discovered. The design and implementation aspects of the proposed system are the main focus of this paper.

Brain↗

Design, implementation and accuracy of a prototype for medical augmented reality.

OBJECTIVE: This paper is focused on prototype development and accuracy evaluation of a medical Augmented Reality (AR) system. The accuracy of such a system is of critical importance for medical use, and is hence considered in detail. We analyze the individual error contributions and the system accuracy of the prototype. MATERIALS AND METHODS: A passive articulated arm is used to track a calibrated end-effector-mounted video camera. The live video view is superimposed in real time with the synchronized graphical view of CT-derived segmented object(s) of interest within a phantom skull. The AR accuracy mostly depends on the accuracy of the tracking technology, the registration procedure, the camera calibration, and the image scanning device (e.g., a CT or MRI scanner). RESULTS: The accuracy of the Microscribe arm was measured to be 0.87 mm. After mounting the camera on the tracking device, the AR accuracy was measured to be 2.74 mm on average (standard deviation = 0.81 mm). After using data from a 2-mm-thick CT scan, the AR error remained essentially the same at an average of 2.75 mm (standard deviation = 1.19 mm). CONCLUSIONS: For neurosurgery, the acceptable error is approximately 2-3 mm, and our prototype approaches these accuracy requirements. The accuracy could be increased with a higher-fidelity tracking system and improved calibration and object registration. The design and methods of this prototype device can be extrapolated to current medical robotics (due to the kinematic similarity) and neuronavigation systems.

Humans↗

Development and human factors analysis of neuronavigation vs. augmented reality.

This paper is focused on the human factors analysis comparing a standard neuronavigation system with an augmented reality system. We use a passive articulated arm (Microscribe, Immersion technology) to track a calibrated end-effector mounted video camera. In real time, we superimpose the live video view with the synchronized graphical view of CT-derived segmented object(s) of interest within a phantom skull. Using the same robotic arm, we have developed a neuronavigation system able to show the end-effector of the arm on orthogonal CT scans. Both the AR and the neuronavigation systems have been shown to be within 3mm of accuracy. A human factors study was conducted in which subjects were asked to draw craniotomies and answer questions to gage their understanding of the phantom objects. The human factors study included 21 subjects and indicated that the subjects performed faster, with more accuracy and less errors using the Augmented Reality interface.

Adult↗