Metabolism of [14C]gemopatrilat after oral administration to rats, dogs, and humans.

This study describes the pharmacokinetic parameters of gemopatrilat, a potent vasopeptidase inhibitor, in humans and the comparative biotransformation of the compound in rats, dogs, and humans after administration of a single oral dose of [14C]gemopatrilat. Gemopatrilat was rapidly absorbed in humans with an oral bioavailability of 49%. Within 5 h after dose, the mean concentrations of gemopatrilat were less than 1% of the mean Cmax values. The total area under the first-moment time curve extrapolated to infinity [AUC(INF)] value for gemopatrilat was only 2% of the AUC(INF) of radioactivity in plasma. Gemopatrilat showed a large apparent steady-state volume of distribution (2500 liters) and a prolonged terminal-phase decline in plasma concentration. These results are consistent with the idea that the free sulfhydryl group of gemopatrilat forms reversible disulfide linkages with plasma and tissue proteins and is thus eliminated from the body at a very slow rate. Approximately half of the drug-related radioactivity in 1-h plasma samples from rat, dog, and human was reduced chemically with dithiothreitol to gemopatrilat, suggesting that disulfide linkage occurred in all species. In addition, metabolites formed through S-methylation and amide hydrolysis were also detected in rat, dog, and human plasma. No gemopatrilat was detected in urine and fecal samples from all three species, indicating that the compound is extensively metabolized in vivo. The major metabolites identified in human urine and feces were also present in rat and dog. These data suggest that the metabolism of gemopatrilat in all three species were qualitatively very similar.

Administration, Oral↗

Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry.

The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.

Animals↗

Utility of porous graphitic carbon stationary phase in quantitative liquid chromatography/tandem mass spectrometry bioanalysis: quantitation of diastereomers in plasma.

A major challenge in selecting an appropriate stationary phase for diastereomeric separation is that it is difficult to predict which of the commercially available stationary phases could achieve the required liquid chromatographic (LC) separation. This work describes the selection and evaluation of a porous graphitic carbon (PGC) column coupled with tandem mass spectrometry (MS/MS) for the simultaneous quantitation of an experimental drug candidate (I), its two diastereomeric metabolites (II and III), and its demethylated metabolite (IV) in rat plasma. In addition, we investigated the PGC column for the separation of another drug candidate (VI), its two diastereomeric metabolites (VII and VIII) and its ketone metabolite (IX). The PGC column showed excellent chromatographic resolution for the two diastereomers II and III, as well as for VII and VIII. In contrast, the required resolution for the diastereomers II and III could not be achieved using silica-bonded C(18), C(30), phenyl, perfluorinated, polar embedded and polar end-capped phases. The PGC column showed ruggedness with excellent reproducibility of retention times, peak symmetry and response over a period of more than 400 injections of a plasma acetonitrile-precipitation extract. Excellent accuracy and precision were achieved, with accuracy of 94-108% and intra- and inter-run precision within 9%. This work indicates that PGC is a valuable addition to the repertoire of LC columns used for quantitative LC/MS/MS bioanalysis, especially where the separation and quantitation of diastereomeric analytes is involved.

Animals↗

LC-MS Development strategies for quantitative bioanalysis.

Although quantitative bioanalysis using liquid chromatography in conjunction with atmospheric pressure ionization tandem mass spectrometry (LC-MS/MS) has been in use for approximately fifteen years, new concepts and technologies are continuously being introduced to enhance the multiple steps of quantitative LC-MS/MS bioanalysis. In this review article, we have focused on concepts and technologies that have recently been introduced to achieve further improvements in biological sample collection/storage and extraction, chromatography and mass spectrometric detection. Under these major headings, a number of specific topics are presented, summarizing the most recent findings in these areas. Included among the topics discussed are: off-line plasma extraction, on-line plasma extraction, enhanced mass resolution, atmospheric pressure photoionization, high-field asymmetric waveform ion mobility spectrometry, electron capture atmospheric pressure chemical ionization, enhancing MS detection via formation of anionic and cationic adducts, chemical derivatization, ultra-performance chromatography, hydrophilic interaction chromatography, and MS-friendly ion-pair reversed-phase chromatography. In the end, we discuss potential pitfalls in LC-MS/MS bioanalysis and the means to avoid them. Such pitfalls may occur due to mass spectral interference from metabolites or prodrugs, due to the use of inappropriate calibration standard and quality control samples for analysis involving unstable drugs or metabolites, and due to the wild card phenomenon commonly known as the matrix effect.

Animals↗

A novel high-throughput automated chip-based nanoelectrospray tandem mass spectrometric method for PAMPA sample analysis.

Parallel artificial membrane permeability assay (PAMPA) has recently gained popularity as a novel, high-throughput assay capable of rapidly screening compounds for their permeability characteristics in early drug discovery. The analytical techniques typically used for PAMPA sample analysis are HPLC-UV, LC/MS or more recently UV-plate reader. The LC techniques, though sturdy and accurate, are often labor and time intensive and are not ideal for high-throughput. On the other hand, UV-plate reader technique is amenable to high-throughput but is not sensitive enough to detect the lower concentrations that are often encountered in early drug discovery work. This article investigates a novel analytical method, a chip-based automated nanoelectrospray mass spectrometric method for its ability to rapidly analyze PAMPA permeability samples. The utility and advantages of this novel analytical method is demonstrated by comparing PAMPA permeability values obtained from nanoelectrospray to those from conventional analytical methods. Ten marketed drugs having a broad range of structural space, physico-chemical properties and extent of intestinal absorption were selected as test compounds for this investigation. PAMPA permeability and recovery experiments were conducted with model compounds followed by analysis by UV-plate reader, UV-HPLC as well as the automated nanoelectrospray technique (nanoESI-MS/MS). There was a very good correlation (r(2) > 0.9) between the results obtained using nanoelectrospray and the other analytical techniques tested. Moreover, the nanoelectrospray approach presented several advantages over the standard techniques such as higher sensitivity and ability to detect individual compounds in cassette studies, making it an attractive high-throughput analytical technique. Thus, it has been demonstrated that nanoelectrospray analysis provides a highly efficient and accurate analytical methodology to analyze PAMPA samples generated in early drug discovery.

Automation↗

Bioavailability enhancement of a poorly water-soluble drug by solid dispersion in polyethylene glycol-polysorbate 80 mixture.

Oral bioavailability of a poorly water-soluble drug was greatly enhanced by using its solid dispersion in a surface-active carrier. The weakly basic drug (pK(a) approximately 5.5) had the highest solubility of 0.1mg/ml at pH 1.5, < 1 microg/ml aqueous solubility between pH 3.5 and 5.5 at 24+/-1 degrees C, and no detectable solubility (< 0.02 microg/ml) at pH greater than 5.5. Two solid dispersion formulations of the drug, one in Gelucire 44/14 and another one in a mixture of polyethylene glycol 3350 (PEG 3350) with polysorbate 80, were prepared by dissolving the drug in the molten carrier (65 degrees C) and filling the melt in hard gelatin capsules. From the two solid dispersion formulations, the PEG 3350-polysorbate 80 was selected for further development. The oral bioavailability of this formulation in dogs was compared with that of a capsule containing micronized drug blended with lactose and microcrystalline cellulose and a liquid solution in a mixture of PEG 400, polysorbate 80 and water. For intravenous administration, a solution in a mixture of propylene glycol, polysorbate 80 and water was used. Absolute oral bioavailability values from the capsule containing micronized drug, the capsule containing solid dispersion and the oral liquid were 1.7+/-1.0%, 35.8+/-5.2% and 59.6+/-21.4%, respectively. Thus, the solid dispersion provided a 21-fold increase in bioavailability of the drug as compared to the capsule containing micronized drug. A capsule formulation containing 25 mg of drug with a total fill weight of 600 mg was subsequently selected for further development. The selected solid dispersion formulation was physically and chemically stable under accelerated storage conditions for at least 6 months. It is hypothesized that polysorbate 80 ensures complete release of drug in a metastable finely dispersed state having a large surface area, which facilitates further solubilization by bile acids in the GI tract and the absorption into the enterocytes. Thus, the bioavailability of this poorly water-soluble drug was greatly enhanced by formulation as a solid dispersion in a surface-active carrier.

Administration, Oral↗

Liquid chromatography-tandem mass spectrometric quantitative determination of the HIV protease inhibitor atazanavir (BMS-232632) in human peripheral blood mononuclear cells (PBMC): practical approaches to PBMC preparation and PBMC assay design for high-throughput analysis.

A selective, accurate, and reproducible LC/MS/MS assay was developed and validated for the determination of the HIV protease inhibitor atazanavir (BMS-232632) in human peripheral blood mononuclear cells (PBMC) samples. In addition to the details of the validated LC/MS/MS method, a practical procedure is described in great detail for the preparation of large supplies of control (blank) PBMC from units of blood (each unit of blood is about 500 ml) for making the calibration standards and quality control (QC) samples. The PBMC assay design, intended for high-throughput sample analysis, is also described in some detail in regards to the composition and concentration expressions of the calibration standards and QC samples, the lysing procedure of the PBMC samples, and the final analysis/quantitation procedure. The method involved automated solid-phase extraction (SPE) of atazanavir and a stable isotope analog internal standard (I.S.) using 3M Empore C2-SD 96-well plates. A portion of the reconstituted sample residue was injected onto a YMC Basic analytical column which was connected to a triple quad mass spectrometer for analyte determination by positive-ion electrospray in the selected reaction monitoring (SRM) mode. The standard curve, which ranged from 5 to 2500 fmol per one million cells (fmol/10(6) cells), was fitted to a quadratic regression model weighted by 1/concentration. The lower limit of quantitation (LLOQ) was 5 fmol/10(6) cells. The inter- and intra-run coefficients of variation (CV) for the assay were <9% and the accuracy was 94-104%. Atazanavir was stable in PBMC for at least 24h at room temperature and for at least 129 days at -15 degrees C.

Atazanavir Sulfate↗

Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.

Selective, accurate, and reproducible liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of mevalonic acid, an intermediate in the biosynthesis of cholesterol and therefore a useful biomarker in the development of cholesterol lowering drugs, in human plasma and urine. A hepta-deuterated analog of mevalonic acid was used as the internal standard. For both methods, calibration standards were prepared in water, instead of human plasma and urine, due to unacceptably high levels of endogenous mevalonic acid. The lower quality control (QC) samples were prepared in water while the higher QC samples were prepared in the biological matrices. For the isolation/purification of mevalonic acid from the plasma and urine matrices, the samples were first acidified to convert the acid analyte into its lactone form. For the plasma samples, the lactone analyte was retained on and then eluted off a polymeric solid-phase extraction (SPE) sorbent. For the urine method, the sample containing the lactone analyte was passed through a C-18 SPE column, which did not retain the analyte, with the subsequent analyte retention on and then elution off a polymeric SPE sorbent. Chromatographic separation was achieved isocratically on a polar-endcapped C-18 analytical column with a water/methanol mobile phase containing 0.5 mM formic acid. Detection was by negative-ion electrospray tandem mass spectrometry. The standard curve range was 0.500-20.0 ng/mL for the plasma method and 25.0-1,000 ng/mL for the urine method. Excellent accuracy and precision were obtained for both methods at all concentration levels tested. It was interesting to note that for certain batches of urine, when a larger sample volume was used for analysis, a high degree of matrix effect was observed which resulted not only in the attenuation of the absolute response, but also in a change of analyte/internal standard response ratio. This demonstrated that, under certain conditions, the use of a stable isotope analog internal standard does not, contrary to conventional thinking, guarantee the constancy of the analyte/internal response ratio, which is a prerequisite for a rugged bioanalytical method. On the other hand, under conditions where the sample matrix does not have such a deleterious effect, we have found that a stable isotope analog could serve as a surrogate (substitute) analyte. Thus, we have shown that using calibration standards prepared by spiking plasma with tri-deuterated or tetra-deuterated mevalonic acid, instead of mevalonic acid itself (the analyte), plasma QC samples that contain mevalonic acid can be successfully analyzed for the accurate and precise quantitation of mevalonic acid. The use of a surrogate analyte provides the opportunity to gauge the daily performance of the method for the low concentration levels prepared in the biological matrix, which otherwise is not achievable because of the endogenous concentrations of the analyte in the biological matrices.

Chromatography, Liquid↗

A strategy for metabolite identification using triple-quadrupole mass spectrometry with enhanced resolution and accurate mass capability.

Using a single platform of a triple-quadrupole mass spectrometer equipped with enhanced resolution and accurate mass capabilities, a strategy for metabolite identification of a drug in a biological matrix has been demonstrated. The strategy is based on first screening for metabolites via neutral loss and precursor ion scan schemes, devised as the result of the product ion spectrum of a matrix-free standard of the drug. The accurate masses of the precursor ions identified via the two scan schemes plus the precursor ions of structurally likely metabolites are then determined by enhanced resolution, accurate mass (AM) selected ion monitoring (SIM). The identities of the metabolites are further established by determining the accurate masses of the product ions via enhanced resolution AM selected reaction monitoring (SRM). The feasibility of the strategy was demonstrated using a liver microsome incubation sample of nefazodone, an antidepressant drug. The neutral loss and precursor ion screening runs were able to identify most of the metabolites of nefazodone. The subsequent SIM and SRM experiments gave mass accuracy of better than +/-0.003 u for the masses of the precursor and product ions of nefazodone and all the metabolites. The ability to perform metabolite screening by using the scan features followed by accurate mass determinations on the same instrument is an attractive feature of using a triple-quadrupole mass spectrometer with enhanced resolution and accurate mass capability.

Animals↗

Enhanced resolution triple-quadrupole mass spectrometry for fast quantitative bioanalysis using liquid chromatography/tandem mass spectrometry: investigations of parameters that affect ruggedness.

In order to increase sample analysis throughput, the use of fast liquid chromatography in quantitative bioanalysis based on liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) has become prevalent. Therefore, it is important to increase the specificity of such bioanalytical methods. This can be done by enhancing both the chromatographic and mass resolving power. Increasing the mass spectrometric resolving power to minimize interference from endogenous compounds in the biological matrix is the subject of this paper. We present the results of our experience with developing and validating SRM-based, enhanced resolution bioanalytical methods using a new triple-quadrupole mass spectrometer with enhanced resolution capability. We have shown that SRM bioanalytical methods using better than unit-mass resolution (Q1 FWHM = 0.2 Th, Q3 FWHM = 0.7 Th) can be developed which are as rugged as unit resolution methods (Q1 FWHM = 0.7 Th, Q3 FWHM = 0.7 Th). The enhanced resolution methods require more attention to detail than unit resolution methods. For instance, the mass setting for precursor ion selection is more critical because the mass peak is narrower. Because of this, enhanced resolution methods may be more easily influenced by temperature changes in the laboratory. We have shown that there is good correlation between the shift in the precursor ion mass and the ambient temperature. Other studies carried out to investigate the effects on mass peak shape and response (both in the SIM and SRM mode) as the result of varying the FWHM revealed some interesting results. For instance, the decrease in response with the decrease in the FWHM was larger using SRM compared to that using SIM. However, the decrease in both SRM and SIM response with decreasing FWHM was significantly smaller compared with the decrease obtained using an older generation instrument. We demonstrate that, at concentrations near the limit of detection, the signal specificity can be improved by using an enhanced resolution method. To compare the performance of an enhanced resolution method against a unit resolution method under optimized mass spectrometric conditions, we analyzed calibration standards and quality control samples using a lower limit of quantitation that could be easily achieved by either method. Under these conditions, the two methods were essentially the same, demonstrating that the enhanced resolution method is as accurate, precise and rugged as the unit resolution method. We propose system suitability procedures, based on precursor ion scan, product ion scan, SRM with fractional mass changes, or SIM with a narrow scan width, for the updating of the SRM set masses before the start of analysis. We also recommend that Q1 SRM masses be determined during and at the end of analysis in order to ascertain whether or not the precursor masses have shifted during the course of the analysis.

Chromatography, Liquid↗

Pharmacokinetics and pharmacodynamics of the vasopeptidase inhibitor, omapatrilat in healthy subjects.

AIMS: To determine the pharmacokinetics, pharmacodynamics and tolerability of omapatrilat, a vasopeptidase inhibitor, in healthy subjects. METHODS: The effects of oral omapatrilat were evaluated in healthy men in two double-blind, placebo-controlled, dose-escalation trials. In a single-dose study, subjects received omapatrilat in doses of 2.5, 7.5, 25, 50, 125, 250, or 500 mg. In a multiple-dose study, subjects received doses of 10, 25, 50, 75, or 125 mg daily for 10 days. RESULTS: In the multiple-dose study, peak plasma concentrations (Cmax = 10-895 ng ml(-1); tmax = 0.5-2 h) of omapatrilat were attained rapidly. Omapatrilat exhibited a long effective half-life (14-19 h), attaining steady state in 3-4 days. In the single-dose study, Cmax (1-1009 ng ml(-1)) and AUC(0,t) (0.4-1891 ng ml(-1) h) were linear but not dose proportional. In the multiple-dose study, based on weighted least-squares linear regression analyses vs dose, Cmax but not AUC(0,t) was linear at the lower doses on day 10. The lowest dose of omapatrilat (2.5 mg) almost completely inhibited (> 97%) serum angiotensin converting enzyme activity at 2 h after dosing. In the multiple dose study, angiotensin converting enzyme activity was inhibited by more than 80% 24 h after all doses of omapatrilat. Inhibition of neutral endopeptidase activity was shown by increases in the daily urinary excretion of atrial natriuretic peptide and cyclic guanosine monophosphate at doses of more than 7.5 and 25 mg, respectively. In the single dose study, omapatrilat increased the daily urinary excretion of atrial natriuretic peptide dose-dependently from 10.8 +/- 4.1 (+/- SD) ng 24 h(-1) in the placebo group to 60.0 +/- 18.2 ng 24 h(-1) in the 500 mg group. Omapatrilat did not affect sodium and potassium excretion or urinary volume. Compared with placebo, omapatrilat produced a decrease in mean arterial pressure at 3 h after all doses in both the single- and multiple-dose studies. CONCLUSIONS: Omapatrilat was generally well tolerated. The pharmacokinetic and pharmacodynamic effects of omapatrilat are consistent with once-daily dosing.

Administration, Oral↗

A strategy for a post-method-validation use of incurred biological samples for establishing the acceptability of a liquid chromatography/tandem mass-spectrometric method for quantitation of drugs in biological samples.

Validated liquid chromatography/tandem mass spectrometric (LC/MS/MS) methods are now widely used for quantitation of drugs in post-dose (incurred) biological samples for the assessment of pharmacokinetic parameters, bioavailability and bioequivalence. In accordance with the practice currently accepted within the pharmaceutical industry and the regulatory bodies, validation of a bioanalytical LC/MS/MS method is performed using standards and quality control (QC) samples prepared by spiking the drug (the analyte) into the appropriate blank biological matrix (e.g. human plasma). The method is then declared to be adequately validated for analyzing incurred biological samples. However, unlike QC samples, incurred samples may contain an epimer or another type of isomer of the drug, such as a Z or E isomer. Such a metabolite will obviously interfere with the selected reaction monitoring (SRM) transition used for the quantitation of the drug. The incurred sample may also contain a non-isomeric metabolite having a molecular mass different from that of the drug (such an acylglucuronide metabolite) that can still contribute to (and hence interfere with) the SRM transition used for the quantitation of the drug. The potential for the SRM interference increases with the use of LC/MS/MS bioanalytical methods with very short run times (e.g. 0.5 min). In addition, a metabolite can potentially undergo degradation or conversion to revert back to the drug during the multiple steps of sample preparation that precede the introduction of the processed sample into the LC/MS/MS system. In this paper, we recommend a set of procedures to undertake with incurred samples, as soon as such samples are available, in order to establish the validity of an LC/MS/MS method for analyzing real-life samples. First, it is recommended that the stability of incurred samples be investigated 'as is' and after sample preparation. Second, it is recommended that potential SRM interference be investigated by analyzing the incurred samples using the same LC/MS/MS method but with the additional incorporation of the SRM transitions attributable to putative metabolites (multi-SRM method). The metabolites monitored will depend on the expected metabolic products of the drug, which are predictable based on the functional groups present in the chemical structure of the drug. Third, it is recommended that potential SRM interference be further investigated by analyzing the incurred samples using the multi-SRM LC/MS/MS method following the modification of chromatographic conditions to enhance chromatographic separation of the drug from any putative metabolites. We will demonstrate the application of the proposed strategy by using a carboxylic acid containing drug candidate and its acylglucuronide as a putative metabolite. Plasma samples from the first-in-man (FIM) study of the drug candidate were used as the incurred samples.

Animals↗