PubMed Health⌕ Search

Biomedical subjects

Mohammed Zourob

Publications and source records attributed to Mohammed Zourob.

8 recordsLinked to original sources

A micro-reactor for preparing uniform molecularly imprinted polymer beads.

In this study, uniform spherical molecularly imprinted polymer beads were prepared via controlled suspension polymerization in a spiral-shaped microchannel using mineral oil and perfluorocarbon liquid as continuous phases. Monodisperse droplets containing the monomers, template, initiator, and porogenic solvent were introduced into the microchannel, and particles of uniform size were produced by subsequent UV polymerization, quickly and without wasting polymer materials. The droplet/particle size was varied by changing the flow conditions in the microfluidic device. The diameter of the resulting products typically had a coefficient of variation (CV) below 2%. The specific binding sites that were created during the imprinting process were analysed via radioligand binding analysis. The molecularly imprinted microspheres produced in the liquid perfluorocarbon continuous phase had a higher binding capacity compared with the particles produced in the mineral oil continuous phase, though it should be noted that the aim of this study was not to optimize or maximize imprinting performance, but rather to demonstrate broad applicability and compatibility with known MIP production methods. The successful imprinting against a model compound using two very different continuous phases (one requiring a surfactant to stabilize the droplets the other not) demonstrates the generality of this current simple approach.

Equipment Design↗

A rapid highly-sensitive endotoxin detection system.

This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm x 6 mm x 28 microm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude-time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel-clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.

Biosensing Techniques↗

An integrated optical leaky waveguide sensor with electrically induced concentration system for the detection of bacteria.

An integrated, sensitive and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor with an electric field. The electric field was used to concentrate Bacillus subtilis var. niger(BG) bacteria spores onto the immobilized anti-BG antibody on the MCLW sensor surface. This sensor combination has been characterised by detecting the scattering from bacterial spores, which are concentrated at the sensor surface, when they are illuminated at the coupling angle; and by detection of fluorescence from labelled antibodies added after the spores had been captured on the surface. The light scattering and fluorescence detection methods gave a detection limit of BG bacterial spores of 1 x 10(3) spores ml(-1) when the electric field was applied for 3 minutes.

Bacillus subtilis↗

Optical leaky waveguide sensor for detection of bacteria with ultrasound attractor force.

An integrated, sensitive, and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor with ultrasound standing waves (USW). The performance of a MCLW sensor for the detection of bacteria has been increased (>100 fold) by using USWs to drive bacteria onto the sensor surface. By forming the USW nodes at or within the surface of the MCLW, the diffusion-limited capture rate has been replaced by fast movement. Immobilized anti-BG antibody on the MCLW sensor surface was used to capture Bacillus subtilis var. niger (BG) bacterial spores driven to the surface. This combination of sensor and attractor force combination has been tested by detecting the evanescent scattering from bacterial spores at the sensor surface. Application of ultrasound for 3 min gave a detection limit for BG bacterial spores of 1 x 10(3) spores/mL.

Bacillus subtilis↗

An integrated disposable dye clad leaky waveguide sensor for micro-TAS applications.

An integrated, disposable, dye clad leaky waveguide (DCLW) device has been fabricated and tested for both refractive index and fluorescence detection in mu-TAS applications. The chip comprises the required flow geometry and optical coupling elements in a robust device that is relatively simple and inexpensive to fabricate. Disposable DCLW chips were fabricated at room temperature by spin-coating both the dye and silica sol-gel waveguiding layers on a polymer substrate which contained injection moulded grating coupler. These devices have been designed to increase the interaction of the evanescent field light at the channel wall and with the sample in the channel. The DCLW device has been used to detect changes in the refractive index of different percentages of glycerol solutions and to detect low concentrations down to 10(-12) M fluorescein using a grating coupler.

Journal Article↗

Metal clad leaky waveguides for chemical and biosensing applications.

Novel metal clad leaky waveguide (MCLW) sensor devices have been developed for sensing applications. These chips are designed to confine the light in a low refractive index waveguide that encompasses the chemically-selective layer, maximising the overlap between the optical mode and the chemistry, thus improving the sensitivity. In this work, a thin metal layer was inserted between the substrate and the thick waveguide layer, increasing the reflectivity of the waveguide/metal interface and decreasing the light lost at each of reflection in the leaky mode, which in turn increases the propagation distance. The device has been used for a range of biosensing applications, including the detection of organophosphoros pesticides. The limit of detection for paraoxon, based on absorbance detection, was calculated to be 6 nM. Refractive index detection was demonstrated by monitoring the change in the out-coupled angle resulting from the binding of protein A to anti-protein A immobilized on agarose. The sensor was also used for detecting the quenching of the fluorescence of an acid-base sensitive ruthenium complex immobilized within the sol-gel and with glucose oxidase enzyme. The limit of detection for glucose was 3 microM. The advantage of using the metal layer in the MCLW was that an electrical potential could be applied to accelerate the diffusion of the analyte to the immobilised antibody, which resulted in a shortened analysis time and a reduction in non-specific binding.

Biosensing Techniques↗

An integrated metal clad leaky waveguide sensor for detection of bacteria.

An integrated optical metal clad leaky waveguide (MCLW) sensor device has been developed for the detection of bacteria. This is more sensitive than waveguide sensors currently in use. The MCLW device has been fabricated to extend the evanescent field to provide significant light intensity over the entire volume of the bacteria bound on the chip surface within this field. This in turn increases the interaction of the light with the entire volume of the bacteria. MCLW devices have been used for detecting refractive index changes, scattering, and fluorescence from bacterial spores captured on an immobilized antibody. The detection limit of Bacillus subtilis var. niger bacterial spores using refractive index detection was 8 x10(4) spores/mL. The scattering intensity of the BG spores was found to be three times greater than the scattering intensity generated using surface plasmon resonance. The extended light propagation along the direction of flow for a few millimeters provides an effective interrogation approach to increase the area of detection to detect low concentrations down to 1 x 10(4) spores/mL. The sensor was then optimized by studying the key factors affecting sensor performance including changing the pH of the medium, type of antibody immobilization matrix, sensor surface regeneration approaches, and longevity of the sensor.

Bacteria↗

Bacteria detection using disposable optical leaky waveguide sensors.

Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR).

Bacillus↗