PubMed Health⌕ Search

Biomedical subjects

Molly S Shoichet

Publications and source records attributed to Molly S Shoichet.

33 records · Page 2Linked to original sources

Immobilized concentration gradients of nerve growth factor guide neurite outgrowth.

Axons are guided to their targets by a combination of haptotactic and chemotactic cues. We previously demonstrated that soluble neurotrophic factor concentration gradients guide axons in a model system. In an attempt to translate this model system to a device for implantation, our goal was to immobilize a stable neurotrophic concentration gradient for axonal (or neurite) guidance. Nerve growth factor (NGF) was immobilized within poly(2-hydroxyethylmethacrylate) [p(HEMA)] microporous gels using a gradient maker. The NGF was stably immobilized, with only approximately 0.05% of the amount originally incorporated into the gel released over an 8-day period. Immobilized NGF was bioactive: the percent of PC12 cells extending neurites on NGF-immobilized p(HEMA) gels was 16 +/- 2%, which was statistically the same as those exposed to soluble NGF (22 +/- 6%). We were able to predict and reproducibly create stable NGF concentration gradients in the gel. At an NGF concentration gradient of 357 ng/mL/mm, PC12 cell neurites were guided up the gradient. The facile, flexible, and reproducible nature of this method allowed us to translate soluble growth factor gradient models to stable growth factor gradient devices that may ultimately enhance axonal guidance and regeneration in vivo.

Animals↗

Synthetic hydrogel guidance channels facilitate regeneration of adult rat brainstem motor axons after complete spinal cord transection.

Synthetic guidance channels or tubes have been shown to promote axonal regeneration within the spinal cord from brainstem motor nuclei with the inclusion of agents such as matrices, cells, or growth factors to the tube. We examined the biocompatibility and regenerative capacity of synthetic hydrogel tubular devices that were composed of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA). Two PHEMA-MMA channels, having a mean elastic modulus of either 177 or 311 kPa were implanted into T8-transected spinal cords of adult Sprague Dawley rats. The cord stumps were inserted into the channels and fibrin glue was applied to the cord-channel interface. An expanded polytetrafluoroethylene (ePTFE) membrane was used for duraplasty. Controls underwent cord transection alone. Gross and microscopic examination of the spinal cords showed continuity of tissue within the synthetic guidance channels between the cord stumps at 4 and 8 weeks. There was a trend towards an increased area and width of bridging neural tissue in the 311-kPa guidance channels compared to the 177-kPa channels. Neurofilament stained axons were visualized within the bridging tissue, and serotonergic axons were found to enter the 311-kPa channel. Retrograde axonal tracing revealed regeneration of axons from reticular, vestibular, and raphe brainstem motor nuclei. For both channels, there was minimal scarring at the channel-cord interface, and less scarring at the channel-dura interface compared to that observed next to the ePTFE. The present study is the first to show that axons from brainstem motor nuclei regenerated in unfilled synthetic hydrogel guidance channels after complete spinal cord transection.

Animals↗

Controlling modulus and morphology of hydrogel tubes through surface modification.

Crosslinked, porous poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA) tubes were prepared in cylindrical glass molds using a new centrifugal casting process developed in our group. The resulting hydrogel tubes have a bi-phasic wall structure, with a spongy inner layer and a gel-like outer layer, the latter of which provides mechanical strength to the tube. While many factors influence wall morphology and, thus, mechanical properties, we focused on the effect of the surface properties of the glass mold in which tubes are synthesized. Specifically, we investigated the impact of a diverse set of silane modifications of the glass mold on tube morphology, elastic modulus and mold release. We treated activated glass surfaces with one of three alkoxysilanes having either ethoxy, amine or fluorocarbon end-groups. Silane-modified glass surfaces were found to be more hydrophobic than the unmodified glass mold, with the most hydrophobic surface being that of the fluorocarbon-terminated silane. The presence of the silane layer on the mold was confirmed by X-ray photoelectron spectroscopy and the stability of this modification was confirmed by examining the surface chemistry of the hydrogel tubes. The biphasic hydrogel tube wall structure was observed for all tubes, yet those tubes synthesized in unmodified molds had a cracked outer morphology, whereas those synthesized in silane-modified molds had a smooth outer morphology. This influenced the mechanical properties of the tubes where tubes synthesized in silane-modified molds had a significantly greater elastic modulus than those tubes synthesized in unmodified molds. Release from the molds was easiest with ethoxy- and amine-functionalized silane mold modifications.

Biocompatible Materials↗

Peripheral nerve regeneration through guidance tubes.

Biological nerve grafts have been extensively utilized in the past to repair peripheral nerve injuries. More recently, the use of synthetic guidance tubes in repairing these injuries has gained in popularity. This review focuses on artificial conduits, nerve regeneration through them, and an account of various synthetic materials that comprise these tubes in experimental animal and clinical trials. It also lists and describes several biomaterial considerations one should regard when designing, developing, and manufacturing potential guidance channel candidates. In the future, it it likely that the most successful synthetic nerve conduit will be one that has been fabricated with some of these strategies in mind.

Animals↗

Bone formation on two-dimensional poly(DL-lactide-co-glycolide) (PLGA) films and three-dimensional PLGA tissue engineering scaffolds in vitro.

For some bone tissue engineering strategies, direct contact of newly synthesized bone with a scaffold is important for structural continuity and stability at the scaffold/bone interface. Thus, as the polymer degrades, the support function of the scaffold could be adopted by the developing bone structure. This study was designed to determine whether poly(DL-lactide-co-glycolide) with a comonomer ratio of 75:25 supports bone apposition in vitro. Osteogenic cells derived from rat bone marrow cells were cultured for 2 weeks on polymeric two-dimensional films and three-dimensional tissue engineering scaffolds. Bacteriological grade polystyrene and tissue culture polystyrene dishes served as negative and positive controls for interfacial bone deposition, respectively. The surfaces of the prepared substrates were characterized by X-ray photoelectron spectroscopy, dynamic water contact angle, scanning electron microscopy, and atomic force microscopy. After cell culture, the elaborated matrix was examined using scanning electron microscopy, transmission electron microscopy, and energy dispersive spectroscopy. The results show that poly(DL-lactide-co-glycolide) supports appositional bone growth on both two-dimensional films and three-dimensional scaffolds, including the formation of a mineralized cement line matrix. Furthermore, surface topographical features are not required for the adherence of the cement line matrix to the polymer.

Animals↗

Novel intrathecal delivery system for treatment of spinal cord injury.

A novel, localized method for potential delivery of therapeutic agents to the injured spinal cord was investigated. The strategy consists of a polymeric drug solution that gels after injection into the subarachnoid space (SAS). By dispersing therapeutic agents in the polymeric solution, a method is provided for localized delivery to the spinal cord. To determine whether intrathecal injection of this drug delivery system (DDS) would affect cerebrospinal fluid (CSF) flow, a spinal canal model was built using dimensional analysis. Blocking up to 52% of the modeled subarachnoid space of the spinal canal caused minimal pressure differences (9.22 +/- 1.45 Pa), suggesting that implantation of a DDS would not subject the spinal cord to increased pressure. The safety of the DDS was also assessed in vivo by injecting collagen into the SAS of Sprague Dawley rats. Controls received injections of artificial CSF (aCSF). Collagen or aCSF was injected at the T2-T3 spinal level of both uninjured rats and rats injured with a 20g compression clip. The injected collagen persisted in the SAS for at least 8 weeks post-implantation and did not elicit an inflammatory reaction in either uninjured or injured animals. Long-term functional behavior was evaluated with the Basso, Beattie, and Bresnahan (BBB) scale weekly for 8 weeks. Functional behavior was similar in the collagen and aCSF groups, also indicating that the DDS was safe. This minimally invasive DDS may provide an alternative, safe method to deliver therapeutic agents intrathecally.

Absorbable Implants↗

Fiber templating of poly(2-hydroxyethyl methacrylate) for neural tissue engineering.

We have developed a method to create longitudinally oriented channels within poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogels for neural tissue engineering applications. Incorporated into an entubulation strategy, these scaffolds have the potential to enhance nerve regeneration after transection injuries of either the spinal cord or the peripheral nerve by increasing the available surface area and providing guidance to extending axons and invading cells. The fabrication process is straightforward and the resultant scaffolds are highly reproducible. Polycaprolactone (PCL) fibers were extruded and embedded in transparent, crosslinked pHEMA gels. Sonication of the pHEMA/PCL composite in acetone resulted in the complete dissolution of the PCL, leaving longitudinally oriented, fiber-free channels in the pHEMA gel. Regulating the size and quantity of the PCL fibers allowed us to control the diameter and number of channels. Small and large channel scaffolds were fabricated and thoroughly characterized. The small channel scaffolds had 142+/-7 channels, with approximately 75% of the channels in the 100-200 micro m size range. The large channel scaffolds had 37+/-1 channels, with approximately 77% of the channels in the 300-400 micro m range. The equilibrium water content (EWC), porosity and compressive modulus were measured for each of the structures. Small and large channel scaffolds had, respectively, EWCs of 55.0+/-1.2% and 56.2+/-2.9%, porosities of 35+/-1% and 40+/-1% and compressive moduli of 191+/-7 and 182+/-4kPa.

Acetone↗

Toward spinal cord injury repair strategies: peptide surface modification of expanded poly(tetrafluoroethylene) fibers for guided neurite outgrowth in vitro.

Expanded poly(tetrafluoroethylene) fibers were surface modified using an ultraviolet-activated mercury/ammonia reaction to yield amine-functional groups for the coupling of laminin-derived cell adhesive peptides CYIGSR, CDPGYIGSR, CIKVAV, and CQAASIKVAV. Surface elemental composition, determined by X-ray photoelectron spectroscopy, and radiolabeling data indicated that the amount of peptide introduced was approximately equivalent regardless of peptide type, yet mixed peptide surfaces had approximately 60% YIGSR and 40% IKVAV. The peptide-modified surfaces were compared in terms of the response of dorsal root ganglia with neurite length and number of cells attached to each fiber measured. All peptide-functionalized surfaces had a greater cellular response than the aminated ePTFE and ePTFE controls. Surfaces modified with extended peptide sequences CDPGYIGSR and CQAASIKVAV demonstrated a greater cellular response than those modified with the shorter peptide sequences CYIGSR and CIKVAV, respectively, likely because the extended peptides more closely mimic the three-dimensional conformation that the peptides maintain in laminin. Differences in neurite extension were evident among the peptide-functionalized surfaces, with the longest neurites observed on surfaces modified with both CQAASIKVAV and CDPGYIGSR. The "guidance capacity" of the fibers as a function of fiber diameter was investigated in terms of length and directionality of neurite outgrowth. As fiber diameter decreased (from 100+ to 10 microm), the neurites tended to grow to a greater degree down the length of the fiber. The thinnest fibers (with diameters <20 microm) extended shorter neurites than the fibers with a wider diameter. Combining neurite length with guidance indicated that of the fiber diameters investigated, the optimal fiber diameter for neurite guidance was between 30 and 50 microm.

Animals↗

Fabrication of precise cylindrical three-dimensional tissue engineering scaffolds for in vitro and in vivo bone engineering applications.

It is sometimes necessary to form highly porous polymeric tissue engineering scaffolds into various shapes and sizes. Ideally, in these cases, the three-dimensional morphology should be maintained to the outer margins of the scaffold so as to provide optimum function. Many biodegradable polymeric scaffolds are soft and delicate, however, and their poor physical strength presents a challenge when cutting these materials into the required shapes. We describe a simple device that can be used quickly and accurately to cut cylindrical shapes from such delicate polymeric scaffold materials, which maintain their morphological features to the margins of the shapes produced. We demonstrate that the device can be used to create scaffolds with reproducible dimensions having an SD in mass of less then 6%. The in vitro utility of scaffolds cut with the device was established through demonstrating bone marrow-derived cell invasion into fibrin-filled scaffolds that fit precisely into the wells of 24-well plates. We also demonstrate the in vivo utility of precise cylindrically shaped scaffolds by observing rapid bone invasion into 2.4-mm diameter scaffolds that have been placed into drill hole defects in the distal femur of young rats. When scaffolds are filled with fibrin before implantation as part of a bone tissue engineering strategy, less blood fills the defect site and the fibrin is gradually remodeled and replaced by bone. The ability to cut precise cylindrical scaffolds in the millimeter size range has allowed for the creation of a new small animal model that may prove useful for screening tissue engineering scaffolds for further study.

Animals↗

In vivo bone engineering in a rabbit femur.

The repair of bone defects in reconstructive surgery has significant limitations. Donor site morbidity, limited supply of autograft, and risks and complications associated with allografting and synthetic bone substitutes are among the most significant. In an effort to address these problems, the search for an ideal bone replacement has led to the development of a new method of poly(lactide-co-glycolide) (PLGA) foam processing, enabling the production of a biodegradable scaffold with similar porosity to human trabecular bone. In this study, these scaffolds were evaluated for bone repair in vivo in a femoral critical-sized segmental defect in New Zealand White (NZW) rabbits. Three groups of nine animals were investigated. In the first group, the critical-sized defects were empty. Scaffolds alone were implanted in the second group, whereas autologous bone marrow cell-loaded scaffolds were implanted in the third group. Animals ambulated freely for 8 weeks after surgery, and bone formation throughout the defects was serially assessed radiographically and quantified using a bone formation index (BFI) measure. Postmortem radiography and histology were also undertaken to examine bone formation. There was a significant effect of applying this technology to the amount of bone formed in the defects as determined by the BFI (F = 3.41, P < 0.05). The mean BFI for the cell-loaded scaffolds was greater than for the control group at all measured time points (2-, 4-, 6-, and 8-week radiographs). This difference was significant for the 2- and 8-week radiographs (P < 0.05). Qualitative histological assessment confirmed these findings. We concluded from these findings that these PLGA scaffolds loaded with marrow-derived progenitor cells yield significant bone formation in a critical-sized rabbit femoral defect. This technology comprising a novel scaffold design and autologous cells may provide an alternative to current strategies for reconstruction of bony defects.

Absorbable Implants↗

Chemically-bound nerve growth factor for neural tissue engineering applications.

In order to promote regeneration after spinal cord injury, growth factors have been applied in vivo to rescue ailing neurons and provide a path finding signal for regenerating neurites. We previously demonstrated that soluble growth factor concentration gradients can guide axons over long distances, but this model is inherently limited to in vitro applications. To translate the use of growth factor gradients to an implantible device for in vivo studies, we developed a photochemical method to bind nerve growth factor (NGF) to microporous poly(2-hydroxyethylmethacrylate) (PHEMA) gels and tested bioactivity in vitro. A cell adhesive photoreactive poly(allylamine) (PAA) was synthesized and characterized. This photoreactive PAA was applied to the surface of the PHEMA gels to provide both a cell adhesive layer and a photoreactive handle for further NGF immobilization. Using a direct ELISA technique, the amount of NGF immobilized on the surface of PHEMA after UV exposure was determined to be 5.65 +/- 0.82 ng/cm2 or 3.4% of the originally applied NGF. A cell-based assay was performed to determine the bioactivity of the immobilized NGF. Using pheochromocytoma (PC-12) cells, 30 +/- 7% of the cell population responded to bound NGF, a response statistically similar to that of cells cultured on collagen in the presence of 40 ng/ml soluble NGF of 39 +/- 12%. These results demonstrate that PHEMA with photochemically bound NGF is bioactive. This photochemical technique may be useful to spatially control the amount of NGF bound to PHEMA using light and thus build a stable concentration gradient.

Animals↗

Growth factor enhancement of peripheral nerve regeneration through a novel synthetic hydrogel tube.

OBJECT: The authors' long-term goal is repair of peripheral nerve injuries by using synthetic nerve guidance devices that improve both regeneration and functional outcome relative to an autograft. They report the in vitro processing and in vivo application of synthetic hydrogel tubes that are filled with collagen gel impregnated with growth factors. METHODS: Poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA) porous 12-mm-long tubes with an inner diameter of 1.3 mm and an outer diameter of 1.8 mm were used to repair surgically created 10-mm gaps in the rat sciatic nerve. The inner lumen of the tubes was filled with collagen matrix alone or matrix supplemented with either neurotropin-3 at 1 microg/ml, brain-derived neurotrophic factor at 1 microg/ml, or acidic fibroblast growth factor (FGF-1) at 1 or 10 microg/ml. Nerve regeneration through the growth factor-enhanced tubes was assessed at 8 weeks after repair by histomorphometric analysis at the midgraft level and in the nerve distal to the tube repair. The tubes were biostable and biocompatible, and supported nerve regeneration in more than 90% of cases. Nerve regeneration was improved in tubes in which growth factors were added, compared with empty tubes and those containing collagen gel alone (negative controls). Tubes filled with 10 microg/ml of FGF-1 dispersed in collagen demonstrated regeneration comparable to autografts (positive controls) and showed significantly better regeneration than the other groups. CONCLUSIONS: The PHEMA-MMA tubes augmented with FGF-1 in their lumens appear to be a promising alternative to autografts for repair of nerve injuries. Studies are in progress to assess the long-term biocompatibility of these implants and to enhance regeneration further.

Animals↗

Manufacture of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) hydrogel tubes for use as nerve guidance channels.

Hydrogel tubes of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) made by liquid-liquid centrifugal casting are being investigated as potential nerve guidance channels in the central nervous system. An important criterion for the nerve guidance channel is that its mechanical properties are similar to those of the spinal cord, where it will be implanted. The formulated p(HEMA-co-MMA) tubes are soft and flexible, consisting of a gel-like outer layer, and an interconnected macroporous, inner layer. The relative thickness of the gel phase to macroporous phase is controlled by the formulation chemistry, and specifically by the ratio of co-monomers, HEMA and MMA. By varying the surface chemistry of the mold within which the tubes are synthesized, tubes were prepared with either a "cracked" or a smooth outer morphology. Tubes with the cracked outer morphology had periodic channels that traversed the wall of the tube, which resulted in a lower modulus than smooth outer morphology tubes, yet likely greater diffusive permeability. For tubes (and not rods) to be formed, phase separation must precede gelation as is detailed in a formulation phase diagram for HEMA, MMA and water. The tensile elastic modulus of p(HEMA-co-MMA) tubes reflected the formulation chemistry, with greater moduli (up to 400 kPa) recorded for tubes having 10 wt% MMA. The p(HEMA-co-MMA) tubes therefore had similar mechanical properties to those of the spinal cord, which has a reported elastic modulus range between 200 and 600 kPa.

Biocompatible Materials↗

Light-activated immobilization of biomolecules to agarose hydrogels for controlled cellular response.

We describe a new method of synthesizing photolabile hydrogel materials for convenient photoimmobilization of biomolecules on surfaces or in 3-D matrixes. Dissolved agarose was modified with photolabile S-(2-nitrobenzyl)cysteine (S-NBC) via 1,1'-carbonyldiimidazole (CDI) activation of primary hydroxyl groups. S-NBC-modified agarose remained soluble and gelable with up to 5% S-NBC substitution, yet gelation was slower and the elastic modulus of the resulting gel was lower than those of unmodified agarose. Irradiating S-NBC-grafted agarose resulted in the loss of the protecting 2-nitrobenzyl groups, thereby exposing free sulfhydryl groups for biomolecular coupling. When appropriately activated with sulfhydryl-reactive groups, either peptides or proteins were effectively immobilized to the photoirradiated hydrogel matrixes, with the irradiation energy dose (i.e., irradiation time) used to control the amount of biomolecule immobilization. When the GRGDS peptide was immobilized on agarose, it was shown to be cell-adhesive and to promote neurite outgrowth from primary, embryonic chick dorsal root ganglion neurons. The immobilized GRGDS surface ligand concentration affected the cellular response: neurite length and density increased with GRGDS surface concentration at low adhesion ligand concentration and then plateaued at higher GRGDS concentration. Grafting 2-nitrobenzyl-protected compounds to hydrogel materials is useful for creating new photolabile hydrogel substrates for light-activated functional group generation and biomolecular immobilization.

Animals↗

Bioengineered strategies for spinal cord repair.

This article reviews bioengineered strategies for spinal cord repair using tissue engineered scaffolds and drug delivery systems. The pathophysiology of spinal cord injury (SCI) is multifactorial and multiphasic, and therefore, it is likely that effective treatments will require combinations of strategies such as neuroprotection to counteract secondary injury, provision of scaffolds to replace lost tissue, and methods to enhance axonal regrowth, synaptic plasticity, and inhibition of astrocytosis. Biomaterials have major advantages for spinal cord repair because of their structural and chemical versatility. To date, various degradable or non-degradable biomaterial polymers have been tested as guidance channels or delivery systems for cellular and non-cellular neuroprotective or neuroregenerative agents in experimental SCI. There is promise that bioengineering technology utilizing cellular treatment strategies, including Schwann cells, olfactory ensheathing glia, or neural stem cells, can promote repair of the injured spinal cord. This review is divided into three parts: (1) degradable and non-degradable biomaterials; (2) device design; and (3) combination strategies with scaffolds. We will show that bioengineering combinations of cellular and non-cellular strategies have enhanced the potential for experimental SCI repair, although further pre-clinical work is required before this technology can be translated to humans.

Animals↗