PubMed Health⌕ Search

Biomedical subjects

Monita Chatterjee

Publications and source records attributed to Monita Chatterjee.

6 recordsLinked to original sources

Auditory stream segregation with cochlear implants: A preliminary report.

Auditory stream segregation was measured in cochlear implant (CI) listeners using a subjective "Yes-No" task in which listeners indicated whether a sequence of stimuli was perceived as two separate streams or not. Stimuli were brief, 50-ms pulse trains A and B, presented in an A_B_A_A_B_A... sequence, with 50 ms in between consecutive stimuli. All stimuli were carefully loudness-balanced prior to the experiments. The cochlear electrode location of A was fixed, while the location of B was varied systematically. Measures of electrode discrimination and subjective perceptual difference were also included for comparison. There was strong intersubject variation in the pattern of results. One of the participants participated in a second series of experiments, the results of which indicated that he was able to perceptually segregate stimuli that were different in cochlear electrode location, as well as stimuli that were different in temporal envelope. Although preliminary, these results suggest that it is possible for some cochlear implant listeners to perceptually segregate stimuli based on differences in cochlear location as well as temporal envelope.

Acoustic Stimulation↗

Effects of stimulation mode, level and location on forward-masked excitation patterns in cochlear implant patients.

In multi-channel cochlear implants, electrical current is delivered to appropriate electrodes in the cochlea to approximate the spatial representation of speech. Theoretically, electrode configurations that restrict the current spread within the cochlea (e.g., bi- or tri-polar stimulation) may provide better spatial selectivity, and in turn, better speech recognition than configurations that produce a broader current spread (e.g., monopolar stimulation). However, the effects of electrode configuration on supra-threshold excitation patterns have not been systematically studied in cochlear implant patients. In the present study, forward-masked excitation patterns were measured in cochlear implant patients as functions of stimulation mode, level and location within the cochlea. All stimuli were 500 pulses-per-second biphasic pulse trains (200 micros/phase, 20 micros inter-phase gap). Masker stimuli were 200 ms in duration; the bi-polar configuration was varied from narrow (BP+1) to wide (BP+17), depending on the test condition. Probe stimuli were 20 ms in duration and the masker-probe delay was 5 ms; the probe configuration was fixed at BP+1. The results indicated that as the distance between the active and return electrodes in a bi-polar pair was increased, the excitation pattern broadened within the cochlea. When the distance between active and return electrodes was sufficiently wide, two peaks were often observed in the excitation pattern, comparable to non-overlapping electric fields produced by widely separated dipoles. Analyses of the normalized data showed little effect of stimulation level on the shape of the excitation pattern.

Adult↗

Noise improves modulation detection by cochlear implant listeners at moderate carrier levels.

Envelope detection and processing are very important for cochlear implant (CI) listeners, who must rely on obtaining significant amounts of acoustic information from the time-varying envelopes of stimuli. In previous work, Chatterjee and Robert [JARO 2(2), 159-171 (2001)] reported on a stochastic-resonance-type effect in modulation detection by CI listeners: optimum levels of noise in the envelope enhanced modulation detection under certain conditions, particularly when the carrier level was low. The results of that study suggested that a low carrier level was sufficient to evoke the observed stochastic resonance effect, but did not clarify whether a low carrier level was necessary to evoke the effect. Modulation thresholds in CI listeners generally decrease with increasing carrier level. The experiments in this study were designed to investigate whether the observed noise-induced enhancement is related to the low carrier level per se, or to the poor modulation sensitivity that accompanies it. This was done by keeping the carrier amplitude fixed at a moderate level and increasing modulation frequency so that modulation sensitivity could be reduced without lowering carrier level. The results suggest that modulation sensitivity, not carrier level, is the primary factor determining the effect of the noise.

Acoustic Stimulation↗

Across- and within-channel envelope interactions in cochlear implant listeners.

The effects of modulated maskers on detection thresholds of a 50-Hz sinusoidal amplitude modulation (SAM) in a signal carrier were measured in nine cochlear implant (CI) listeners as a function of masker envelope type and for different masker-signal electrode separations. Both signal and masker were 200-ms-long pulse trains, presented concurrently in an interleaved stimulation mode. Masker envelopes were SAM at 20, 50, (0- and pi-phase re: the signal modulator), and 125 Hz, as well as noise amplitude modulated (NAM), all with a fixed 20% modulation depth. Comparisons were made against steady-state maskers that had an amplitude equal to the mean amplitude of the modulated maskers or to their peak amplitude (SS(peak)). Modulation thresholds were larger in the presence of the dynamic maskers versus the SS(peak) maskers; however, there was significant intersubject variability in the pattern of results. Effects of relative phase between masker and signal were not consistent across subjects. Envelope masking (the dB difference in modulation detection thresholds between modulated and SS(peak) maskers) was generally larger for the lower-modulation-frequency maskers than the 125-Hz masker. The spatial distribution of masked modulation detection thresholds was found to be considerably different from spatial forward-masking patterns obtained in the same subjects. Finally, modulation thresholds measured for a very wide separation between the masker and signal showed significant envelope masking. These results suggest that, as has been shown in acoustic stimulation, central, across-channel temporal processing mechanisms also occur in electrical stimulation.

Acoustic Stimulation↗

Modulation masking in cochlear implant listeners: envelope versus tonotopic components.

It is hypothesized that channel-interaction in cochlear implant listeners as measured in a modulation-masking experiment would be influenced by both the tonotopic overlap between masker and signal as well as an interaction between their envelopes. Two experiments were conducted to measure the effects of maskers with noisy and steady-state envelopes on modulation detection by four adult Nucleus-22 cochlear implant listeners, as a function of tonotopic distance between the masker and the signal. In the first experiment, we measured detection thresholds for a 50-Hz modulation in the envelope of a 500-Hz carrier pulse train, in the presence of a masker stimulating regions basal and apical to, as well as overlapping with, the signal. The maskers had two kinds of envelopes: (i) amplitude-modulated by flat-spectrum noise (NAM) and (ii) steady-state (SS(peak)) at a level corresponding to the maximum of the noise fluctuation range. In general, modulation thresholds obtained in the presence of the NAM maskers significantly exceeded thresholds obtained with the corresponding SS(peak) maskers. The ratio p of the threshold modulation depth m obtained with the NAM masker to that obtained with the SS(peak) masker was defined as a conservative index of "envelope masking." In the second experiment, p was determined for two different tasks: the detection of modulation at 20 Hz and steady-state intensity increment detection. Compared to the 50-Hz modulation detection results, the ratio p was reduced for the 20-Hz modulation detection task and even more so for the steady-state increment detection task. It is concluded that channel-interaction can be significantly increased in cochlear implant listeners when dynamic stimuli are used in place of steady-state stimuli.

Adult↗

Maturation of cochlear nonlinearity as measured by distortion product otoacoustic emission suppression growth in humans.

The growth of distortion product otoacoustic emission (DPOAE) suppression follows a systematic, frequency-dependent pattern. The pattern is consistent with direct measures of basilar-membrane response growth, psychoacoustic measures of masking growth, and measures of neural rate growth. This pattern has its basis in the recognized nonlinear properties of basilar-membrane motion and, as such, the DPOAE suppression growth paradigm can be applied to human neonates to study the maturation of cochlear nonlinearity. The objective of this experiment was to investigate the maturation of human cochlear nonlinearity and define the time course for this maturational process. Normal-hearing adults, children, term-born neonates, and premature neonates, plus a small number of children with sensorineural hearing loss, were included in this experiment. DPOAE suppression growth was measured at two f2 frequencies (1500 and 6000 Hz) and three primary tone levels (55-45, 65-55, and 75-65 dB SPL). Slope of DPOAE suppression growth, as well as an asymmetry ratio (to compare slope for suppressor tones below and above f2 frequency), were generated. Suppression threshold was also measured in all subjects. Findings indicate that both term-born neonates and premature neonates who have attained term-like age, show non-adult-like DPOAE suppression growth for low-frequency suppressor tones. These age effects are most evident at f2 = 6000 Hz. In neonates, suppression growth is shallower and suppression thresholds are elevated for suppressor tones lower in frequency than f2. Additionally, the asymmetry ratio is smaller in neonates, indicating that the typical frequency-dependent pattern of suppression growth is not present. These findings suggest that an immaturity of cochlear nonlinearity persists into the first months of postnatal life. DPOAE suppression growth examined for a small group of hearing-impaired children also showed abnormalities.

Acoustic Stimulation↗