PubMed Health⌕ Search

Biomedical subjects

Moritz Hoevels

Publications and source records attributed to Moritz Hoevels.

3 recordsLinked to original sources

Impact of target point deviations on control and complication probabilities in stereotactic radiosurgery of AVMs and metastases.

OBJECTIVE: Determination of the impact of inaccuracies in the determination and setup of the target point in stereotactic radiosurgery (SRS) on the expectable complication and control probabilities. METHODS: Two randomized samples of patients with arteriovenous malformation (AVM) (n=20) and with brain metastases (n=20) treated with SRS were formed, and the probability for complete obliteration (COP) or complete remission (CRP), the size of the 10 Gy-volume in the brain tissue (VOI10), and the probability for radiation necrosis (NTCP) were calculated. The dose-effect relations for COP and CRP were fitted to clinical data. Target point deviations were simulated through random vectors and the resulting probabilities and volumes were calculated and compared with the values of the treatment plan. RESULTS: The decrease of the relative value of the control probabilities at 1mm target point deviation was up to 4% for AVMs and up to 10% for metastases. At 2 mm the median decrease was 5% for AVMs and 9% for metastases. The value for the target point deviation, at which COP and CRP decreased about 0.05 in 90% of the cases, was 1.3 mm. The increase of NTCP was maximally 0.0025 per mm target point deviation for AVMs and 0.0035/mm for metastases. The maximal increase of VOI10 was 0.7 cm(3)/mm target point deviation in both patient groups. CONCLUSIONS: The upper limit for tolerable target point deviations is at 1.3mm. If this value cannot be achieved during the system test, a supplementary safety margin should be applied for the definition of the target volume. A better accuracy level is desirable, in order to ensure optimal chances for the success of the treatment. The target point precision is less important for the minimization of the probability of radiation necroses.

Brain↗

Delineation of brain tumor extent with [11C]L-methionine positron emission tomography: local comparison with stereotactic histopathology.

PURPOSE: Methyl-[11C]L-methionine ([11C]MET) positron emission tomography (PET) in brain tumors reflects amino acid transport and has been shown to be more sensitive than magnetic resonance imaging in stereotactic biopsy planning. It remains unclear whether the increased [11C]MET uptake is limited to solid tumor tissue or even detects infiltrating tumor parts. EXPERIMENTAL DESIGN: In 30 patients, a primary or recurrent brain tumor was suspected on magnetic resonance imaging. Patients were investigated with [11C]MET-PET before stereotactic biopsy. The biopsy trajectories were plotted into the [11C]MET-PET images with a newly designed C-based software program. The exact local [11C]MET uptake was determined within rectangular regions of interest of 4 mm in width and length aligned with the biopsy specimen. Individual histologic specimens were rated for the presence of solid tumor tissue, infiltration area, and nontumorous tissue changes. RESULTS: Receiver operating characteristics analysis demonstrated a sensitivity of 87% and specificity of 89% for the detection of tumor tissue at a threshold of 1.3-fold [11C]MET uptake relative to normal brain tissue. At this threshold, only 13 of 100 tumor positive specimen were false negative mainly in grade 2 astrocytoma. In grade 2 astrocytoma, mean [11C]MET uptake in the infiltration area was significantly higher than in solid tumor tissue (P < 0.003). CONCLUSIONS: [11C]MET-PET detects solid parts of brain tumors, as well as the infiltration area at high sensitivity and specificity. High [11C]MET uptake in infiltrating tumor of astrocytoma WHO grade 2 reflects high activity in this tumor compartment. Molecular imaging, with [11C]MET, will guide improved management of patients with brain tumors.

Adult↗

Optimized distortion correction of epi-based statistical parametrical maps for stereotactic neurosurgery.

A new approach is presented for unwarping geometrical distortions in echo planar imaging (EPI)-based statistical parametrical maps (SPM). With the developed method, a substantial reduction of geometrical distortions in the order of 5-15 mm down to a residue of approximately 1-2 mm was possible, thus allowing reliable activation localization and, hence, interpretation after fusion with undistorted conventional anatomic images. The unwarping procedure is an optimized combination of two distortion correction methods, the "inhomogeneity mapping" and the coregistration approach. Local and global distortions, the first one object-dependent, the second one caused by imperfect gradient waveforms, are reduced. With several examples of patients and volunteers, the applicability for stereotactic neurosurgery is demonstrated.

Adult↗