Image formation in vibro-acoustography with depth-of-field effects.

We study the image formation of vibro-acoustography systems based on a concave sector array transducer taking into account depth-of-field effects. The system point-spread function (PSF) is defined in terms of the acoustic emission of a point-target in response to the dynamic radiation stress of ultrasound. The PSF on the focal plane and the axis of the transducer are presented. To extend the obtained PSF to the 3D-space, we assume it is a separable function in the axial direction and the focal plane of the transducer. In this model, an image is formed through the 3D convolution of the PSF with an object function. Experimental vibro-acoustography images of a breast phantom with lesion-like inclusions were compared with simulated images. Results show that the experimental images are in good agreement with the proposed model.

Elasticity↗

Difference frequency and its harmonic emitted by microbubbles under dual frequency excitation.

Vibro-acoustography is an elasticity imaging method that uses two ultrasound beams of slightly different frequency to excite an object and detects the resulting acoustic emission (AE) at the difference frequency. This method is especially sensitive to bubbles due to their nonlinearity. This study explores the harmonic acoustic emission (HAE) at twice the difference frequency emitted from bubbles. A perturbation method based on the dynamic bubble equation is used to derive the AE and HAE from a single bubble excited by dual frequency waves. Simulation shows that HAE is generated only by microbubbles whose resonant frequencies match the incident ultrasound frequencies. In contrast, AE is more sensitive to resonance at the difference frequency, which is relevant to sub-millimeter bubbles. This finding was confirmed by experiments where HAE was produced from Optison microbubbles, but not from larger air bubbles which are off resonance at the incident ultrasound frequency. In conclusion, harmonic acoustic emission is present for microbubbles. It is very sensitive to the size of the bubble and may be used for selective detection of microbubbles.

Albumins↗

Critical issues in breast imaging by vibro-acoustography.

Clinically, there are two important issues in breast imaging: detection of microcalcifications and identification of mass lesions. X-ray mammography is the main imaging method used for detection of microcalcification, and ultrasound imaging is normally used for detection of mass lesions in breast. Both these methods have limitations that reduce their clinical usefulness. For this reasons, alternative breast imaging modalities are being sought. vibro-acoustography is an imaging modality that has emerged in recent years. This method is based on low-frequency harmonic vibrations induced in the object by the radiation force of ultrasound. This paper describes potential applications of vibro-acoustography for breast imaging and addresses the critical imaging issues such as detection of microcalcifications and mass lesions in breast. Recently, we have developed a vibro-acoustography system for in vivo breast imaging and have tested it on a number of volunteers. Resulting images show soft tissue structures and calcifications within breast with high contrast, high resolution, and no speckles. The results have been verified using X-ray mammography. The encouraging results from in vitro and in vivo experiments suggest that further development of vibro-acoustography technology may lead to a new clinical tool that can be used to detect microcalcifications as well as mass lesions in breast.

Breast Neoplasms↗

Multifrequency vibro-acoustography.

Elasticity imaging is a burgeoning medical imaging field. Many methods have been proposed that impart a force to tissue and measure the mechanical response. One method, vibro-acoustography, uses the ultrasound radiation force to harmonically vibrate tissue and measure the resulting acoustic emission field with a nearby hydrophone. Another method, vibrometry, uses the ultrasound radiation force accompanied with a measurement of the resulting velocity or displacement of the vibrating tissue or object has also been used for different applications. An extension of the vibro-acoustography method using a multifrequency stress field to vibrate an object is described. The objective of this paper is to present the image formation theory for multifrequency vibro-acoustography. We show that the number of low-frequency components created by this multifrequency method scales with the square of the number of ultrasound sources used. We provide experimental validation of the point-spread function of the multifrequency stress field and show examples of both vibrometry and vibro-acoustography imaging applications. This method holds the potential for a large gain of information with no increase in scanning time compared to conventional vibro-acoustography systems.

Acoustics↗

Vibrational characteristics of bone fracture and fracture repair: application to excised rat femur.

BACKGROUND: The vibrational characteristics of any object are directly dependent on the physical properties of that object. Therefore, changing the physical properties of an object will cause the object to adopt changed natural frequencies. A fracture in a bone results in the loss of mechanical stability of the bone. This change in mechanical properties of a bone should result in a change of the resonant frequencies of that bone. A vibrational method for bone evaluation has been introduced. METHOD OF APPROACH: This method uses the radiation force of focused amplitude-modulated ultrasound to exert a vibrating force directly, and remotely, on a bone. The vibration frequency is varied in the range of interest to induce resonances in the bone. The resulting bone motion is recorded and the resonance frequencies are determined. Experiments are conducted on excised rat femurs and resonance frequencies of intact, fractured, and bonded (simulating healed) bones are measured. RESULTS: The experiments demonstrate that changes in the resonance frequency are indicative of bone fracture and healing, i.e., the fractured bone exhibits a lower resonance frequency than the intact bone, and the resonance frequency of the bonded bone approaches that of the intact bone. CONCLUSION: It is concluded that the proposed radiation force method may be used as a remote and noninvasive tool for monitoring bone fracture and healing process, and the use of focused ultrasound enables one to selectively evaluate individual bones.

Animals↗

Noncontact modal analysis of a pipe organ reed using airborne ultrasound stimulated vibrometry.

The goal of this study was to excite and measure, in a noncontact manner, the vibrational modes of the reed from a reed organ pipe. To perform ultrasound stimulated excitation, the audio-range difference frequency between a pair of ultrasound beams produced a radiation force that induced vibrations. The resulting vibrational deflection shapes were measured with a scanning laser vibrometer. The resonances of any relatively small object can be studied in air using this technique. For a 36 mm x 6 mm brass reed, displacements and velocities in excess of 5 microm and 4 mm/s could be imparted at the fundamental frequency of 145 Hz. Using the same ultrasound transducer, excitation across the entire range of audio frequencies was obtained. Since the beam was focused on the reed, ultrasound stimulated excitation eliminated background effects observed during mechanical shaker excitation, such as vibrations of clamps and supports. The results obtained using single, dual and confocal ultrasound transducers in AM and two-beam modes, along with results obtained using a mechanical shaker and audio excitation using a speaker are discussed.

Journal Article↗

Enhanced desorption of RDX from granular activated carbon.

Several methods (cosolvents, surfactants, and cyclodextrins) were compared for improving desorption of a high explosive, RDX, from granular activated carbon (GAC). In batch desorption tests, 3% of the adsorbed RDX (initially 71.1 mg RDX/g GAC) was desorbed by water over 11 days, compared to 92.6% desorption by 100% ethanol. Solutions of ethanol or methanol in water also effectively desorbed RDX, although methanol was somewhat less effective than ethanol. Sodium dodecyl sulfate desorbed as much as 70% of the adsorbed RDX, while the non-ionic surfactants Tween 80, Triton X-100, and Brij 30 desorbed as much as 42 to 51% of the RDX. In continuous flow column tests, GAC was partially regenerated. One-half of the adsorbed RDX was desorbed by 2100 bed volumes (BV) of 10% ethanol, compared to the 22 500 BV of buffered water. Column modeling indicated that competitive adsorption and altered equilibrium conditions combined to enhance RDX desorption.

Adsorption↗

Dynamic ultrasound radiation force in fluids.

The subject of this paper is to present a theory for the dynamic radiation force produced by dual-frequency ultrasound beams in lossless and nondispersive fluids. An integral formula for the dynamic radiation force exerted on a three-dimensional object by a dual-frequency beam is obtained stemming from the fluid dynamics equations. The static radiation force due to a monochromatic wave appears as a particular case of this theory. Dependence of the dynamic radiation force to nonlinear effects of the medium is analyzed. We calculate the dynamic radiation force exerted on solid elastic spheres of two different materials by a low-amplitude dual-frequency plane wave. The static and dynamic radiation forces exhibited approximately same magnitude. Resonance patterns observed in the dynamic radiation force are similar to those present in the static radiation force.

Journal Article↗

Measurement of dynamic and static radiation force on a sphere.

Dynamic radiation force from ultrasound has found increasing applications in elasticity imaging methods such as vibro-acoustography. Radiation force that has both static and dynamic components can be produced by interfering two ultrasound beams of slightly different frequencies. This paper presents a method to measure both static and dynamic components of the radiation force on a sphere suspended by thin threads in water. Due to ultrasound radiation force, the sphere deflects to an equilibrant position and vibrates around it. The static radiation force is estimated from the deflection of the sphere. The dynamic radiation force is estimated from the calculated radiation impedance of the sphere and its vibration speed measured by a laser vibrometer. Experimental results on spheres of different size, vibrated at various frequencies, confirm the theoretical prediction that the dynamic and static radiation force on a sphere have approximately equal magnitudes [G. T. Silva, Phys. Rev. E 71, 056617 (2005)].

Acoustics↗

Noninvasive method for estimation of complex elastic modulus of arterial vessels.

Pulse wave velocity (PWV) is widely used for estimating the stiffness of an artery. It is well-known that a stiffened artery can be associated with various diseases and with aging. Usually, PWV is measured using the "foot-to-foot" method in which the travel time of the wave is measured over a distance. The "foot" of the pressure wave is not clear due to reflected waves and blood noise. Also, PWV is an average indicator of artery stiffness between the two measuring points and, therefore, does not identify local stiffness variations. We propose producing a bending wave in the arterial wall using low-frequency, localized ultrasound radiation force and measuring the wave velocity along the arterial wall. The wave velocity can be measured accurately over a few millimeters. A mathematical model for wave propagation along the artery is developed with which the Young's modulus of the artery can be determined from measured wave velocities. Experiments were conducted on a pig carotid artery cast in a tissue-mimicking gelatin. The wave velocity was measured by the phase change at a known distance for a given frequency. The measured wave velocity is about 3 m/s at 100 Hz and 6.5 m/s at 500 Hz. The real part of complex elastic modulus of the artery is estimated to be 300 kPa.

Animals↗

Stress field forming of sector array transducers for vibro-acoustography.

This paper presents a study of the stress field forming of sector array transducers for vibro-acoustography applications. The system point-spread function (PSF) is given in terms of the dynamic radiation stress exerted on a point target by a dual ultrasound beam with slightly different frequencies. The radiation stress is calculated by assuming that the resulting ultrasound beam is a plane wave. The stress is proportional to the product of the velocity potential of each incident ultrasound beam. The beamforming and stress field forming of sector array transducers are analyzed through linear acoustics. An expression for the velocity potential produced by sector array transducers is derived. The vibro-acoustography PSF is evaluated numerically. A comparison between the PSF of a sector array and a confocal transducers is presented. The compared characteristics of the PSF are sidelobe levels, transverse, and in-depth spatial resolution. Indeed, one motivation to study sector transducers is the fact the depth-of-field of these transducers should be smaller than that of same size confocal transducers. An experimental setup was used to validate the theoretical PSF of sector array transducers. Results show that the measured PSF is in good agreement with the theoretical predications. Vibro-acoustography images of a breast-phantom by both transducers are presented and discussed.

Acoustics↗

Characteristics of the audio sound generated by ultrasound imaging systems.

Medical ultrasound scanners use high-energy pulses to probe the human body. The radiation force resulting from the impact of such pulses on an object can vibrate the object, producing a localized high-intensity sound in the audible range. Here, a theoretical model for the audio sound generated by ultrasound scanners is presented. This model describes the temporal and spectral characteristics of the sound. It has been shown that the sound has rich frequency components at the pulse repetition frequency and its harmonics. Experiments have been conducted in a water tank to measure the sound generated by a clinical ultrasound scanner in various operational modes. Results are in general agreement with the theory. It is shown that a typical ultrasound scanner with a typical spatial-peak pulse-average intensity value at 2 MHz may generate a localized sound-pressure level close to 100 dB relative to 20 microPa in the audible (< 20 kHz) range under laboratory conditions. These findings suggest that fetuses may become exposed to a high-intensity audio sound during maternal ultrasound examinations. Therefore, contrary to common beliefs, ultrasound may not be considered a passive tool in fetal imaging.

Acoustic Stimulation↗

Potential applications of vibro-acoustography in breast imaging.

Vibro-acoustography has gained interest in the recent years as a new modality for medical imaging. This method is based on low-frequency vibrations induced in the object by the radiation force of ultrasound. This paper focuses on potential applications of vibro-acoustography in breast imaging, including detection of microcalcifications, detection of arterial calcifications, and soft tissue imaging. In addition, we will briefly discuss our recent results of in vivo breast vibro-acoustography. Future developments and potential impact of vibro-acoustography in breast imaging are also discussed.

Aged↗

Performance of vibro-acoustography in detecting microcalcifications in excised human breast tissue: a study of 74 tissue samples.

X-ray mammography is the principal modality used today for detection of breast microcalcifications and breast lesions associated with breast cancer. X-ray mammography, however, is ionizing and its sensitivity is greatly reduced in dense breasts. Hence, alternative noninvasive and nonionizing breast imaging tools that can aid physicians to better diagnose early-stage breast lesions are of great interest. Vibro-acoustography is a novel noninvasive imaging technique that uses ultrasound in a fundamentally new way. This method uses the radiation force of ultrasound to vibrate the tissue at low (kilohertz) frequency and records the resulting response to produce images that are related to the mechanical properties of the tissue. The goal of this study is to evaluate the performance of vibro-acoustography in detecting breast microcalcifications by conducting vibro-acoustography on 74 fixed breast tissue samples with known microcalcifications based on their radiographs. The results indicate that in most cases micro-calcifications can be detected by vibro-acoustography. Further development of vibro-acoustography may lead to a novel-imaging tool for in vivo detection of microcalcifications.

Acoustics↗

Imaging mass lesions by vibro-acoustography: modeling and experiments.

Vibro-acoustography is a recently developed imaging method based on the dynamic response of to low-frequency vibration produced by of ultrasound radiation force. The main differentiating feature of this method is that the image includes information about the dynamic properties of the object at the frequency of the vibration, which is normally much lower than the ultrasound frequency. Such information is not available from conventional ultrasound imaging. The purpose of this study is to evaluate the performance of vibro-acoustography in imaging mass lesions in soft tissue. Such lesions normally have elastic properties that are different from the surrounding tissue. Here, we first present a brief formulation of image formation in vibro-acoustography. Then we study vibro-acoustography of solid masses through computer simulation and in vitro experiments. Experiments are conducted on excised fixed liver tissues. Resulting images show lesions with enhanced boundary and often with distinctive textures relative to their background. The results suggest that vibro-acoustography maybe a clinically useful imaging modality for detection of mass lesions.

Algorithms↗

Quantifying elasticity and viscosity from measurement of shear wave speed dispersion.

The propagation speed of shear waves is related to frequency and the complex stiffness (shear elasticity and viscosity) of the medium. A method is presented to solve for shear elasticity and viscosity of a homogeneous medium by measuring shear wave speed dispersion. Harmonic radiation force, introduced by modulating the energy density of incident ultrasound, is used to generate cylindrical shear waves of various frequencies in a homogeneous medium. The speed of shear waves is measured from phase shift detected over the distance propagated. Measurements of shear wave speed at multiple frequencies are fit with the theoretical model to solve for the complex stiffness of the medium. Experiments in gelatin phantoms show promising results validated by an independent method. Practical considerations and challenges in possible medical applications are discussed.

Adipose Tissue↗

Linear arrays for vibro-acoustography: a numerical simulation study.

In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave or tone-burst signals at slightly different frequencies. The system beamforming is modeled in a homogeneous and lossless fluid. In this model, the point-spread function (psf) of the system is obtained as the product of the spatial impulse function of each linear array. Three linear array configurations are analyzed for vibro-acoustography systems. Simulations considering 64 elements in each array are performed. Aspects related to clinical applications ofvibro-acoustography, such as system spatial resolution, sidelobes, grating lobes and image frame-rate are discussed. It is concluded that linear array transducers can produce acceptable spatial resolution for clinical applications.

Acoustics↗

Spectral normalization for ultrasonic contrast microbubble detection.

Ultrasonic contrast agents consisting of microbubbles are used to assess tissue perfusion. The microbubbles are highly reflective and nonlinear and thus produce harmonics that are stronger than those from tissues. However, the magnitude of harmonic signals resulting from a region with microbubbles also depends on the acoustic pressure of incident ultrasound and the attenuation of intervening tissues in the ultrasound path. Therefore, the harmonic magnitude, as used in traditional harmonic imaging, may not be a reliable indicator of the presence or absence of microbubbles, and hence, tissue perfusion. To compensate for these effects, we present two parameters defined as the ratio of the harmonic to the fundamental component (HFR) and the ratio of the harmonic to squared fundamental (HSFR). A simplified model is used to illustrate the usefulness of these two parameters. Experiments show that both parameters improve detection of microbubbles and that HSFR performs better than HFR.

Contrast Media↗