Low-order chaos in sympathetic nerve activity and scaling of heartbeat intervals.

The mechanism of 1/f scaling of heartbeat intervals remains unknown. We recorded heartbeat intervals, sympathetic nerve activity, and blood pressure in conscious rats with normal or high blood pressure. Using nonlinear analyses, we demonstrate that the dynamics of this system of three variables is low-order chaos, and that sympathetic nerve activity leads to heartbeat interval and blood pressure changes. It is suggested that impaired regulation of blood pressure by sympathetic nerve activity is likely to cause experimentally observable steeper scaling of heartbeat intervals in hypertensive (high blood pressure) rats.

Algorithms↗

Artificial myocardium with an artificial baroreflex system using nano technology.

Where is the place which should be helped in a patient with congestive heart failure? The answer may be contraction of the heart. At Tohoku University, development research of "the artificial myocardium" has been conducted, using a ball screw type electromagnetic motor. Furthermore, super-miniaturization is being attempted at present. Thus, a system with shape memory alloy is being developed. The cooling speed problem was solved by the application of the Peltier element. A drive at a speed equal to that of a heartbeat was realized by the application of this system. At present, a ventricular assist device is used for patients waiting for a heart transplant in Japan. An air driven type system disturbs a patient's QOL remarkably because it is connected to the drive device. With our concept, energy is provided by using the electromagnetic force from outside of the body by the use of transcutaneous energy transmission system. Magnetic shielding by amorphous fibers was used at Tohoku University to improve the total efficiency. A natural heart can alter the cardiac output corresponding to the demand. Artificial internal organs must participate in the system of the living body, too. Tohoku University has developed a resistance based artificial heart control algorithm, which simulated a baroreflex system to cope with every demand. Nano level sensing equipment is now under development at Tohoku University. At present, development is being conducted aiming at an "intelligent artificial myocardium".

Baroreflex↗

Potentiated sympathetic nervous and renin-angiotensin systems reduce nonlinear correlation between sympathetic activity and blood pressure in conscious spontaneously hypertensive rats.

BACKGROUND: Patients with a reduced nonlinear component of heart rate regulation have a poorer outcome. METHODS AND RESULTS: We investigated whether a nonlinear correlation between renal sympathetic nerve activity (RSNA) and blood pressure or renal blood flow is reduced in conscious, spontaneously hypertensive rats (SHR) by comparing them with normotensive Wistar-Kyoto rats (WKY). We also determined the linearity and nonlinearity of the correlation in SHR who were given an angiotensin II receptor blocker, candesartan, orally for 2 weeks. The RSNA value was higher in SHR than in WKY, and coherence peaks of transfer function were found at 0.05 and 0.80 Hz (ie, below respiratory- and cardiac-related fluctuations). The coherence (linearity) of the transfer function was significantly higher and gain was smaller in SHR than in WKY. Because mutual information values (linear and nonlinear correlation) were similar in both strains, we found the nonlinear correlation to be lower in SHR than in WKY. Time delay values calculated by the mutual information method demonstrated that RSNA preceded blood pressure and renal blood flow by 0.5 to 1.0 s. In SHR given candesartan, the RSNA value was lower, and the linearity was lower and nonlinearity higher than SHR given vehicle. CONCLUSIONS: Linear correlation between RSNA and blood pressure or renal blood flow was higher in SHR than in WKY, whereas the nonlinear correlation was lower. Oral treatment with candesartan increased the nonlinearity and reduced the linearity in SHR. Increased RSNA and the renin-angiotensin system may be responsible for the lower nonlinearity and higher linearity in hypertension.

Administration, Oral↗