Stentless vs. stented aortic valve replacement: left ventricular mass regression.

The aim of this retrospective study was to evaluate the time-related regression of left ventricular hypertrophy after stentless vs. stented aortic valve replacement. From January 1992 to December 2002, 145 patients had a Toronto stentless porcine valve and 106 had a stented Carpentier-Edwards aortic valve replacement. Over a 10-year follow-up, survival was superior in the Toronto group vs. the Carpentier-Edwards group (84% vs. 74% at 4 years; 78% vs. 68% at 6 years; p < 0.001). A significant and constant reduction of peak and mean transvalvular gradients after valve replacement resulted in substantial regression of left ventricular mass index in both groups, which did not reach statistical significance. However, this phenomenon stopped at 3 years, and left ventricular mass index increased slowly after 5 years. Stentless and stented bioprostheses both showed good early and late clinical and hemodynamic outcomes, with the advantage of better midterm survival for stentless xenografts.

Adult↗

Aortic valve replacement with Toronto SPV in elderly patients: 10-year results.

A retrospective assessment of clinical and echocardiographic variables was performed in 145 patients who received a Toronto SPV aortic valve replacement. The majority (90%) of these elderly patients (mean age, 75.5 +/- 7.4 years) were preoperatively in New York Heart Association class III-IV. Operative mortality was 4.8%. Follow-up was complete up to 10 years and revealed few valve-related complications: thromboembolism (7), bleeding (4), and prosthesis dysfunction necessitating reoperation (3). Late mortality was cardiac-related in 11.7% and noncardiac-related in 17.2%. Actuarial survival was 83% at 5 years and 63% at 8 years. Echocardiography showed low transvalvular gradients (peak, 17.5 +/- 7.5 mm Hg; mean, 9.2 +/- 4.2 mm Hg) resulting in a significant reduction in left ventricular mass index during the first 3 years. Independent of the transprosthetic gradient, left ventricular mass index tended to increase again beyond the 5th year, which correlated positively with the presence of arterial hypertension in this older population. The Toronto SPV bioprosthesis offers an aortic valve substitute with excellent long-term hemodynamics, resulting in significant early left ventricular mass regression. Considering the limitations of this selected elderly population, the clinical outcome and survival up to 10 years are encouraging, with few observed valve-related events.

Aged↗