PubMed Health⌕ Search

Biomedical subjects

Munther Ajlouni

Publications and source records attributed to Munther Ajlouni.

9 recordsLinked to original sources

Partial volume tolerance of the spinal cord and complications of single-dose radiosurgery.

BACKGROUND: Spine radiosurgery causes a rapid dose fall-off within the spinal cord. The tolerance of partial volume of the spinal cord may determine the extent of clinical application. The study analyzed the partial volume tolerance of the human spinal cord to single fraction radiosurgery. METHODS: A total of 230 lesions with spine metastases in 177 patients were treated with radiosurgery with single fraction of 8 to 18 Gy, prescribed to the 90% isodose line that encompassed the target volume. Spinal cord volume was defined as 6 mm above and below the radiosurgery target volume. Spinal cord dose was calculated from the radiation dose/spinal cord volume histogram and correlated with clinical/neurological status and radiographic studies. Median follow-up was 6.4 months (range, 0.5-49 months). The 1-year survival rate was 49%. RESULTS: The average spinal cord volume defined at the treated spinal segment was 5.9 +/- 2.2 mL. The average dose to the 10% spinal cord volume was 9.8 +/- 1.5 Gy, calculated from the dose-volume histogram in the group of 18 Gy prescribed dose. The spinal cord volume that received higher than 80% of the prescribed dose was 0.07 +/- 0.10 mL, which represented 1.3 +/- 1.8% of the cord volume. Among the 86 patients who survived longer than 1 year there was 1 case of radiation-induced cord injury after 13 months of radiosurgery. There were no other cases of spinal cord sequelae. CONCLUSIONS: Whereas the maximum spinal cord tolerance to single-dose radiation is not known, partial volume tolerance of the human spinal cord is at least 10 Gy to 10% of the spinal cord volume defined as 6 mm above and below the radiosurgery target.

Adolescent↗

A technique of using gated-CT images to determine internal target volume (ITV) for fractionated stereotactic lung radiotherapy.

BACKGROUND AND PURPOSE: To develop and evaluate a technique and procedure of using gated-CT images in combination with PET image to determine the internal target volume (ITV), which could reduce the planning target volume (PTV) with adequate target coverage. PATIENTS AND METHODS: A skin marker-based gating system connected to a regular single slice CT scanner was used for this study. A motion phantom with adjustable motion amplitude was used to evaluate the CT gating system. Specifically, objects of various sizes/shapes, considered as virtual tumors, were placed on the phantom to evaluate the number of phases of gated images required to determine the ITV while taking into account tumor size, shape and motion. A procedure of using gated-CT and PET images to define ITV for patients was developed and was tested in patients enrolled in an IRB approved protocol. RESULTS: The CT gating system was capable of removing motion artifacts for target motion as large as 3-cm when it was gated at optimal phases. A phantom study showed that two gated-CT scans at the end of expiration and the end of inspiration would be sufficient to determine the ITV for tumor motion less than 1-cm, and another mid-phase scan would be required for tumors with 2-cm motion, especially for small tumors. For patients, the ITV encompassing visible tumors in all sets of gated-CT and regular spiral CT images seemed to be consistent with the target volume determined from PET images. PTV expanded from the ITV with a setup uncertainty margin had less volume than PTVs from spiral CT images with a 10-mm generalized margin or an individualized margin determined at fluoroscopy. CONCLUSIONS: A technique of determining the ITV using gated-CT images was developed and was clinically implemented successfully for fractionated stereotactic lung radiotherapy.

Algorithms↗

The correlation evaluation of a tumor tracking system using multiple external markers.

The purpose of this study is to evaluate the correlations between external markers and internal targets for radiation therapy of lung cancer patients. Using an infrared camera system coupled with a clinical simulator, the simultaneous motions of multiple external markers and an internal target were obtained. The correlation between external and internal signals was analyzed using a cross-covariance function. A linear regression model was employed to generate a composite signal from multiple external markers in order to predict the internal target motion. The external and internal signals, and their correlations, demonstrated a wide range of variation with respect to marker location, motion dimension, and breathing pattern. The performance of the composite signal indicates that when more external signals were taken into account, the mean correlation between the composite signal and internal signal was improved. This implies that a combination of multiple external signals might be an improved way to predict internal target motion. Also, since the characteristics of respiratory signals can vary significantly, certain methods of preprocessing and external signal combination are necessary.

Artifacts↗

Adaptive prediction of internal target motion using external marker motion: a technical study.

An adaptive prediction approach was developed to infer internal target position by external marker positions. First, a prediction model (or adaptive neural network) is developed to infer target position from its former positions. For both internal target and external marker motion, two networks with the same type are created. Next, a linear model is established to correlate the prediction errors of both neural networks. Based on this, the prediction error of an internal target position can be reconstructed by the linear combination of the prediction errors of the external markers. Finally, the next position of the internal target is estimated by the network and subsequently corrected by the reconstructed prediction error. In a similar way, future positions are inferred as their previous positions are predicted and corrected. This method was examined by clinical data. The results demonstrated that an improvement (10% on average) of correlation between predicted signal and real internal motion was achieved, in comparison with the correlation between external markers and internal target motion. Based on the clinical data (with correlation coefficient 0.75 on average) observed between external marker and internal target motions, a prediction error (23% on average) of internal target position was achieved. The preliminary results indicated that this method is helpful to improve the predictability of internal target motion with the additional information of external marker signals. A consistent correlation between external and internal signals is important for prediction accuracy.

Algorithms↗

Dosimetric study using different leaf-width MLCs for treatment planning of dynamic conformal arcs and intensity-modulated radiosurgery.

This paper systematically studied the dosimetric difference between a 3 mm micro multileaf collimator (MLC), a 5 mm MLC, and a 10 mm MLC for stereotactic radiosurgery using the Brainscan treatment planning system. Thirty-four cases treated with the dynamic conformal arcs technique and 20 cases treated with the intensity modulated radiosurgery/fractionated radiotherapy (IMRS/ IMRT) technique were retrospectively studied. The conformity index, the percentage target coverage, and the dose-volume histogram (DVH) for organs-at-risk (OARs) were used for dosimetric analysis and comparison for different treatment techniques, target volumes, and treatment sites. For the dynamic conformal arcs technique, there were statistically significant differences in the conformity indices between different leaf-width MLCs. The ratio of the conformity indices between different MLCs depended on the target volume. The average conformity index ratios between the 5 mm MLC and the 3 mm MLC were 1.37+/-0.09, 1.12+/-0.04, 1.08+/-0.02 and 1.04+/-0.01, respectively, for patients with the target volume (V) in groups: (1) V< 1 cm3, (2) 1 cm3 < V< 8 cm3, (3) 8 cm3 < V< 27 cm3, and (4) V> 27 CC. The average conformity index ratios between the 10 and 3 mm MLCs were 2.00+/-0.33, 1.45+/-0.09, 1.28+/-0.09, and 1.18+/-0.05 for patients in these four volume groups, respectively. No statistically significant difference was found for the target coverage among different MLCs. For the IMRS/IMRT technique, the average conformity index and target coverage ratios were 1.01+/-0.05 and 1.00+/-0.02, respectively, between the 5 and 3 mm MLCs, and were 1.04+/-0.07 and 0.97+/-0.02, respectively, between the 10 and 3 mm MLCs. The 3 mm MLC showed slightly better overall OAR DVHs than the 5 and 10 mm MLCs, especially for the cranial site with small-volume OARs defined. The results suggest that for the dynamic conformal arcs technique, the narrower leaf-width MLC provides better dose conformity than the wider leaf-width MLCs. This advantage decreases when the target volume increases. For the IMRS/IMRT technique, the narrower leaf-width MLC could have better sparing of small OARs than the wider leaf-width MLC.

Body Burden↗

Image-guided radiosurgery of head and neck cancers.

OBJECTIVES: Radiosurgery precisely delivers a single high dose or a few fractionated doses of radiation to a localized tumor via the stereotactic approach. Some head and neck sites are suitable for radiosurgery since there is minimal or no organ motion. The clinical studies were carried out to determine the accuracy of stereotactic radiosurgery and to demonstrate the effectiveness of radiosurgery in head and neck cancers. MATERIALS AND METHODS: Thirteen patients were treated with either single-dose or fractionated radiosurgery to the tumor. All patients except one with cancer of the lip had received prior treatments including surgery, radiotherapy, and chemotherapy for the primary cancers. The dose ranged 12 to 18 Gy for single-dose radiosurgery and 30 Gy in 5 or 6 fractions twice a week for fractionated radiosurgery. Tumor localization was achieved via the stereotactic approach. RESULTS: Accuracy of radiosurgery was within 1.5 mm. Despite the recurrent disease from previous heavy treatments, 9 patients (70%) showed a significant response (complete or >50% tumor reduction) to radiosurgery, and 3 patients had stable disease. Complete tumor response was achieved in 6 patients. All patients had excellent pain relief with functional and cosmetic preservation. There was no acute and subacute radiation toxicity detected clinically during the minimal follow-up of 6 months. CONCLUSION: Image-guided radiosurgery is effective in achieving the local tumor control and pain relief. Radiosurgery provided excellent functional and cosmetic preservation with minimal complication. The results indicate the potential of radiosurgery in the treatment of recurrent and selected primary head and neck cancers.

Carcinoma, Squamous Cell↗

Image-guided procedures for intensity-modulated spinal radiosurgery. Technical note.

Radiosurgery for brain tumors has been well established in the radiation oncology and neurosurgery fields. Radiosurgery of extracranial tumors such as those involving the spine is, however, still in the early stage because of difficulties in patient immobilization and organ motion. The authors describe an image-guided procedure for intensity-modulated spinal radiosurgery that was developed at Henry Ford Hospital.

Algorithms↗

Image-guided and intensity-modulated radiosurgery for patients with spinal metastasis.

BACKGROUND: Radiosurgery can deliver a single, large radiation dose to a localized tumor using a stereotactic approach and hence, requires accurate and precise delivery of radiation to the target. Of the extracranial organ targets, the spine is considered a suitable site for radiosurgery, because there is minimal or no breathing-related organ movement. The authors studied spinal radiosurgery in patients with spinal metastases to determine its accuracy and precision. METHODS: The spinal radiosurgery program was based on an image-guided and intensity-modulated, shaped-beam radiosurgical unit. It is equipped with micromultileaf collimators for beam shaping and radiation intensity modulation and with a noninvasive, frameless positioning device that uses infrared, passive marker technology together with corroborative image fusion of the digitally reconstructed image from computed tomography (CT) simulation and orthogonal X-ray imagery at the treatment position. These images were compared with the port films that were taken at the time of treatment to determine the accuracy of the isocenter position. Clinical feasibility was tested in 10 patients who had spinal metastasis with or without spinal cord compression. The patients were treated with fractionated external beam radiotherapy followed by single-dose radiosurgery as a boost (6-8 grays) to the most involved portion of the spine or to the site of spinal cord compression. RESULTS: The accuracy for the isocenter was within 1.36 mm +/- 0.11 mm, as measured by image fusion of the digitally reconstructed image from CT simulation and the port film. Clinically, the majority of patients had prompt pain relief within 2-4 weeks of treatment. Complete and partial recovery of motor function also was achieved in patients with spinal cord compression. The radiation dose to the spinal cord was minimal. The maximum dose of radiation to the anterior edge of the spinal cord within a transverse section, on average, was 50% of the prescribed dose. There was no acute radiation toxicity detected clinically during the mean follow-up of 6 months. CONCLUSIONS: Image-guided, shaped-beam spinal radiosurgery is accurate and precise. Rapid clinical improvement of pain and neurologic function also may be achieved. The results indicate the potential of spinal radiosurgery in the treatment of patients with spinal metastasis, especially those with solitary sites of spine involvement, to increase the prospects of long-term palliation.

Feasibility Studies↗

A technique of intensity-modulated radiosurgery (IMRS) for spinal tumors.

This study is to demonstrate the feasibility of spinal radiosurgery using an image-guided intensity-modulated radiosurgical (IMRS) procedure. A dedicated Novalis shaped beam surgery unit equipped with a built-in micro-multileaf collimator (mMLC) with a single 6 MV photon beam was used. Each patient was simulated in the supine position using an AcQsim CT simulator with infrared sensitive markers for localization. A variety of different treatment plans were developed, but the most common plan was the use of seven coplanar intensity-modulated beams to minimize radiation to critical organs such as the spinal cord and kidneys. An automatic localization device based on infrared and video cameras was used to guide the initial patient setup. Two keV x-ray imaging systems were used to identify potential deviations from the planned isocenter. A total of 25 patients with spinal tumors have been treated using this procedure with a single prescription dose ranging from 6 to 12 Gy. The final verification images indicated that the average isocenter deviation from the planned isocenter was within 2 mm. The phantom verification of isocenter doses indicated that the average deviation of measured isocenter doses from the planned isocenter doses for all patients treated with intensity-modulated beams was less than 2%. Film dose measurement in a phantom study demonstrated good agreement of above 50% isodose lines between the planned and measured results. Preliminary experience shows that precision delivery of high dose radiation could be administered to the planned target volume while the dose to the critical organs is kept within tolerable limits.

Computer Simulation↗