PubMed Health⌕ Search

Biomedical subjects

Mustafa Guden

Publications and source records attributed to Mustafa Guden.

10 recordsLinked to original sources

Robotic-enhanced totally endoscopic mitral valve repair and ablative therapy.

PURPOSE: The aim of this article was to assess the feasibility of totally closed robotic mitral valve repair and ablative therapy. DESCRIPTION: Two patients with mitral valve disease and permanent atrial fibrillation underwent the combined procedure using the da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA). Radiofrequency ablation was performed using the Cardioblate XL unipolar pen (Medtronic Inc, Minneapolis, MN). One patient underwent mitral commissurotomy and the other commissurotomy and Reed annuloplasty. EVALUATION: There were no procedure-related complications. Sinus rhythm was established in both patients after the operation, and transesophageal echocardiography revealed competent mitral valves without residual gradients. CONCLUSIONS: Robotic-enhanced mitral valve repair and ablation proved feasible in both patients with good clinical outcome. The described combined method may find broader application in a selected group of patients with the continuing evolution in technology.

Atrial Fibrillation↗

Combined off-pump coronary artery bypass grafting surgery and ablative therapy for atrial fibrillation: early and mid-term results.

BACKGROUND: The aim of this study was to evaluate the feasibility of off-pump coronary artery bypass grafting combined with radiofrequency ablation and to compare outcomes between patients with permanent and paroxysmal atrial fibrillation (AF) in terms of restoring sinus rhythm. METHODS: Thirty-three patients underwent the combined procedure. Mean age was 62.34 +/- 8.20 years; there were 12 female and 21 male patients. Twenty-one patients were diagnosed as permanent AF (group A) and 12 had paroxysmal AF (group B). After the off-pump revascularization patients underwent pulmonary vein ablation. Rhythm was evaluated at discharge and at 6 and 12 months' follow-up. Patients in stable sinus rhythm underwent transthoracic echocardiographic examination to evaluate atrial contractility at 6 and 12 months. RESULTS: There was no operative mortality or major complications. The mean ablation time was 11 +/- 3.4 minutes, including multiple applications. At the end of the procedure 84.5% of patients were free of AF. Sinus rhythm was established in 56% (group A, 52%; group B, 58.3%), 70.5% (group A, 58%; group B, 83.3%), and 71% (group A, 59%; group B, 83.3%) of patients at discharge and at 6 and 12 months, respectively (p = 0.249). Biatrial contractility was detected in 71% of group A and 76% of group B patients at 6 months' follow-up. More patients in group A returned to AF during follow-up when compared with group B (p = 0.016). Female sex (odds ratio, 2.1), chronic lung disease (odds ratio, 1.40), left ventricular disfunction (p = 0.016), and hypertension (odds ratio, 2.57) emerged as risk factors for AF recurrence after ablation. CONCLUSIONS: Concomitant off-pump coronary artery bypass grafting and bipolar radiofrequency ablation was safe and effective. These patients should be considered for adjunctive treatment at the time of off-pump revascularization.

Aged↗

Chylothorax after aortic valve replacement.

A 71-year-old-man was diagnosed with chylothorax after aortic valve replacement. He was treated with a low-fat diet and pleural drainage with thoracentesis. The pleural effusion completely resolved by the 14th postoperative day.

Aged↗

Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery.

OBJECTIVE: The aim of this study was to assess the feasibility and safety of a new proximal anastomotic device during off-pump coronary surgery. METHODS: The Novare Enclose II is a manual proximal anastomotic device that enables the surgeon to perform proximal anastomoses without side-biting clamps in a fully pressurized aorta. The device was used in 30 off-pump coronary artery bypass graft (CABG) patients (Group A) for performing 25 vein, 10 free right internal thoracic artery and 14 radial artery anastomoses to the aorta. The number of proximal anastomoses varied between 1 and 3 per patient. Intraoperative transcranial Doppler measurements were performed to detect cerebral microemboli during the use of the device and were compared with transcranial Doppler measurements of 30 off-pump patients where a partial side clamp was used for proximal anastomoses (Group B). The aorta was evaluated using transesophageal echocardiography (TEE) and epiaortic echocardiography (EAE) in both groups before the procedure and patients with a calcified aorta were excluded. RESULTS: In Group A, 49 proximal anostomoses were performed as planned with the device using conventional hand-sewn methods. Twenty-four of these were arterial conduits. In Group B, 32 proximal anastomoses were performed using 25 veins and 7 arterial grafts. There were no procedure related to adverse events or complications in both groups. The median number of microemboli was 15 (range 5-48) in Group A and 68 (range 35-290) in Group B (P<0.05). CONCLUSION: The Enclose II device can be a valuable tool to perform venous or arterial proximal anastomoses during off-pump CABG. Transcranial Doppler results suggest that the device seems to be less traumatizing than side clamping and may reduce clamp-associated complications during off-pump coronary artery surgery.

Anastomosis, Surgical↗

Does off-pump CABG reduce gastrointestinal complications?

BACKGROUND: The aim of this study was to compare gastrointestinal complications and associated risk factors among patients undergoing cardiac surgery using off- and on-pump revascularization techniques. METHODS: A total of 1146 adult patients who underwent coronary artery surgery during a 6-year period were evaluated retrospectively. Group 1 consisted of 546 patients operated using off-pump techniques and group 2 consisted of 600 cases operated with cardiopulmonary bypass. Patients were compared and evaluated for gastrointestinal complications and possible associated risk factors using univariate and multivariate logistic regression analysis. RESULTS: Overall mortality was 1.6% in group 1 and 2.2% in group 2 (p = 0.523). Mortality due to gastrointestinal complications was 38.5% and 35.7% respectively in group 1 and group 2. The mean EuroSCORE value was 5.1 +/- 2.8 in group 1 and 3.8 +/- 2.4 in group 2 (p < 0.001). The most common gastrointestinal complication in the off-pump group was gastrointestinal bleeding. The leading complication in group 2 was intestinal ischemia. CONCLUSIONS: The incidence rates of gastrointestinal complications were similar in the on- and off-pump coronary artery bypass groups, the type of gastrointestinal complications, however, was different. Mortality rate due to these complications was also similar and remained high, regardless of the type of surgery. Cardiopulmonary bypass did not emerge as a risk factor for gastrointestinal complications, but prolonged cardiopulmonary bypass (longer than 98 minutes) resulted in a high incidence of such complications. Old age and advanced arteriosclerosis emerged as risk factors in both groups resulting in gastrointestinal complications suggesting the ischemic nature of the injury.

Aged↗

Combined radiofrequency ablation and myxoma resection through a port access approach.

Myxomas are common cardiac tumors that are traditionally managed by complete excision through a median sternotomy approach with the use of cardiopulmonary bypass. We discuss a patient with left atrial myxoma and chronic atrial fibrillation who underwent surgical excision and combined irrigated radiofrequency ablation for atrial fibrillation through a Port Access approach. Minimally invasive operations constitute an expanding field for the treatment of many cardiac diseases and may be an alternative for the treatment of this pathology because of less surgical trauma and cosmetic superiority. In this case, both excision of the myxoma and radiofrequency ablation were feasible through this minimally invasive approach. The combination of direct and endoscopic views enabled both procedures to be performed safely and efficiently.

Atrial Fibrillation↗

Combined radiofrequency modified maze and mitral valve procedure through a port access approach: early and mid-term results.

OBJECTIVE: The aim of this study was to assess the feasibility and effectiveness of irrigated radiofrequency (RF) modified Maze procedure through a port access approach during mitral valve surgery and evaluate early and mid-term results. MATERIAL AND METHOD: During a 16 months time period, 67 patients with chronic atrial fibrillation (AF) eligible for port access mitral valve surgery were randomly assigned to either Group A, in which they underwent a combined procedure (N = 33) or Group B, in which a valve procedure alone was performed (N = 34). Both groups were similar in terms of age, sex, valve pathology, duration of AF left atrial diameter and left ventricle function (P > 0.05). Four had undergone previous operations. RESULTS: Median follow-up was 10 months for both groups, 95% CI (9.18-10.8). One patient in each group died early postoperatively (3 and 2.9%). Two patients required reoperation for bleeding, one in each group (3 and 2.9%). There were two conversions to right thoracotomy. In Group A, freedom from AF was 100% at the end of the operation (76% sinus, 24% pacemaker) Six and twelve months freedom from AF was 87.2 and 93.6%, respectively. In Group B, freedom from AF at the end of operation was 41%. At the end of 6 and 12 months, freedom from AF was 9.4% (P = 0.0001). One patient in Group A required a permanent pacemaker (3%). During follow-up, one patient in Group A died of non-cardiac causes (3%). In Group B, there were two late deaths: one cardiac (2.9%) and one neurologic (2.9%). There were no thromboembolic events detected in Group A during follow-up, whereas two patients in Group B suffered this complication (6%, P = 0.081). At 12 months, functional capacity had improved for patients in both groups (P < 0.0001). CONCLUSION: The combination of mitral valve surgery and irrigated RF Maze procedure was safe and efficient through a port access approach. There were no procedure related complications like esophageal or coronary artery injury. Early and mid-term results were favourable with 93.6% of patients free of AF at 1 year in comparison to the 9.4% of the control group. The data is not sufficient to reach any conclusions in terms of thromboembolic rates, despite favourable results for the RF Maze group. Nevertheless, in terms of feasibilty, sinus rhythm restoration and overall outcome, early results are encouraging and we advocate the use of the combined procedure through a port access approach.

Adult↗

Left versus bi-atrial intraoperative saline-irrigated radiofrequency modified maze procedure for atrial fibrillation.

BACKGROUND: This study was conducted to evaluate the effectiveness of the saline-irrigated radiofrequency modified maze operation for the treatment of chronic atrial fibrillation (AF) and compare the results of the left and bi-atrial procedures. MATERIAL AND METHOD: During a period of two years, 105 patients with chronic AF having concomitant cardiac surgery underwent the procedure. Patients underwent either a bi-atrial ( n = 48) or left atrial ( n = 57) maze procedure. The first twenty patients underwent a bi-atrial maze procedure regardless of the pathology. In the following patients we adopted the bi-atrial approach in patients with a history of atrial flutter and where the right atrium has to be opened. Otherwise the procedure is restricted to the left atrial side. Mean age was 52 +/- 11 years in bi-atrial group and 54 +/- 9 years in left atrial group. RESULTS: Three patients died early postoperatively (2.9%). There were 4 revisions for bleeding (3.8%). Two patients in bi-atrial group received a permanent pacemaker (4.1%). Patients in both groups were free of AF at the end of the procedure. (Bi-atrial group: sinus: 79.2%, pacemaker: 20.8%), (Left atrial group: sinus: 82.5%, pacemaker: 17.5%) ( p > 0.05). During the last follow-up, sinus rhythm was maintained in 79.6% of cases in bi-atrial group, while this rate was 75.6% in left atrial group ( p > 0.05). CONCLUSION: Saline irrigated radiofrequency modified maze procedure was performed safely and efficiently. Both the left and bi-atrial procedures were successful in terms of restoring sinus rhythm. Our current policy is to adopt the bi-atrial approach in patients with a history of atrial flutter and where the right atrium has to be opened. Otherwise the procedure is restricted to the left atrial side.

Adult↗

Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery.

The purpose of this prospective study was to evaluate graft patency of off-pump coronary artery surgery intraoperatively by transit-time flow measurement and to compare this technique with postoperative magnetic resonance flow mapping. Twenty patients (13 men and 7 women; mean age, 679 +/- 76 yr) underwent off-pump coronary artery surgery. Intraoperative transit-time flow measurement of grafts was performed measuring maximum, minimum, and mean flows. For each graft, the pulsatile index was calculated by dividing the difference between the maximum and the minimum flow by the mean flow In the early postoperative period (1st week), magnetic resonance flow mapping was performed using phase contrast flow quantification. Mean intraoperative flow values and mean magnetic resonance flow mapping values were compared. At the same postoperative session, contrast-enhanced magnetic resonance angiography was performed to evaluate graft patency. In 20 patients, a total of 49 coronary graft flows were assessed with intraoperative transit-time flow measurement and postoperative magnetic resonance flow mapping. Upon comparison, there was a strong correlation between techniques, with stable and statistically significant differences between the intraoperative and postoperative flow mapping values. One saphenous vein graft was revised intraoperatively, due to graft failure. Our data suggest that the combined use of intraoperative transit-time flow measurement and postoperative magnetic resonance flow analysis has a potential role in the assessment of graft patency in off-pump coronary artery surgery although more study is required.

Aged↗