PubMed Health⌕ Search

Biomedical subjects

Muthana Al-Ghazi

Publications and source records attributed to Muthana Al-Ghazi.

2 recordsLinked to original sources

Intensity-modulated radiation therapy for the spine at the University of California, Irvine.

Radiation treatment of malignant diseases of the spine poses unique challenges to the radiation oncology treatment team. Intensity-modulated radiation therapy (IMRT) offers the capability of delivering high doses to targets near the spine while respecting spinal cord tolerance. At the University of California, Irvine, 8 patients received a total of 10 courses to the spine for a variety of primary and metastatic malignant conditions. This paper discusses anatomical considerations, spinal cord radiation myelopathy, and treatment planning issues as it relates to the treatment of spinal cord lesions. Between October 1997 and August 2001, a total of 8 patients received 10 courses of IMRT for primary or metastatic disease of the spine. Cancers treated included metastatic lung, renal, adrenocortical cancers, and primary sarcomas and giant cell tumor. Five cases had 6 courses given for re-irradiation of symptomatic disease and 3 cases had 4 courses of IMRT as primary management of their spinal lesions. Although 3 courses were given postoperatively, these were for grossly residual disease. For the re-irradiation patients, the mean follow-up interval was 4 months. The local control was estimated at 14%. Of the patients treated with primary intent, the mean follow-up was 9 months and the local control rate 75%. No patients developed spinal cord complications.

Academic Medical Centers↗

Reshapable physical modulator for intensity modulated radiation therapy.

A new method of generating beam intensity modulation filters for intensity modulated radiation therapy (IMRT) is presented. The modulator was based on a reshapable material, which is not compressible but can be deformed under pressure. A two-dimensional (2D) piston array was used to repeatedly shape the attenuating material. The material is a mixture of tungsten powder and a silicon-based binder. The linear attenuation coefficient of the material was measured to be 0.409 cm(-1) for a 6 MV x-ray beam. The maximum thickness of the physical modulator is 10.2 cm, allowing a transmission of 1.5%. A 16 x 16 square piston array was used to generate a depth pattern in the deformable attenuating material. Each piston has a cross section of 6.37 x 6.37 mm2. The modulator was placed 65 cm from the radiation source of the linear accelerator in the position of the shielding tray. At this position, each piston projects to a 1.0 x 1.0 cm2 area at the isocenter, giving a treatment field of 16 x 16 cm2. The percent depth dose curve and output factor measurement show a slight beam hardening and a 1%-4% increase in scatter fraction when 2.2-4.4 cm uniform thickness filters are in the beam. The surface dose was decreased with the filter in the beam. Ion chamber and verification films were used to verify the entrance dose. The measured absolute and relative doses were compared with the calculated dose. The agreement of measurements and calculations is within 3%. In order to verify the spatial modulation of dose, 1-D dose profiles were obtained using dose calculations. Calculated and measured profiles were compared. The 20%-80% penumbra of the modulator was measured to be 5.5-10 mm. The results show that a physical modulator formed using a 16 x 16 piston array and a deformable attenuation material can provide intensity modulation for IMRT comparable with those provided by currently available commercial MLC techniques.

Biophysical Phenomena↗