PubMed Health⌕ Search

Biomedical subjects

My Moberg

Publications and source records attributed to My Moberg.

6 recordsLinked to original sources

Divergent activities of human glutathione transferases in the bioactivation of azathioprine.

Azathioprine is a thiopurine prodrug clinically used for immunosuppression in the treatment of inflammatory diseases and in pharmacological regimens of organ transplantations. Its pharmacological action is based on the release of 6-mercaptopurine, but the biochemical processes underlying this biotransformation have remained obscure. In this investigation, human glutathione transferases (GSTs) from seven distinct classes were assayed with azathioprine. GSTs A1-1, A2-2, and M1-1, all abundantly expressed in human liver, displayed the highest activity among the 14 GSTs tested. The uncatalyzed reaction of azathioprine with glutathione was estimated to be less than 1% of the GST-catalyzed biotransformation. GST M1-1 is polymorphic with a frequently occurring null allele, and GSTs A1-1 and A2-2 show variable expression levels in human subjects, implying significant differences in the rate of 6-mercaptopurine release from azathioprine. Individuals expressing high GST activity are apparently predisposed for adverse reactions to azathioprine treatment, both by promoting excessively high concentrations of free 6-mercaptopurine and its toxic metabolites and by depleting cellular glutathione. These novel aspects of GST-dependent azathioprine biotransformation have not been considered previously.

Azathioprine↗

A generic stepwise optimization strategy for liquid chromatography electrospray ionization tandem mass spectrometry methods.

The feasibility and advantages of using sophisticated chemometric tools in combination with the execution of thoroughly planned experiments to determine experimental conditions for optimal performance of an LC-ESI-MS/MS analysis is demonstrated. A stepwise strategy is proposed, which provides a controlled optimization procedure of the chromatographic quality (in terms of separation among the sample constituents) and maximizes the mass spectrometric signal of the selected product ions. Design of experiments (DOE) and response surface methodology are applied throughout the procedure. The stepwise approach has the advantage of dealing with the different optimization criteria separately, i.e. first ensuring sufficient chromatographic separation, then maximizing the amount of precursor ion entering the mass spectrometer, and finally generating high amounts of selected product ions. The experiments are performed on a linear ion trap mass spectrometer. Retention mapping using the band-tracking model is applied during LC development, which facilitates the optimization of segmented gradients. A set of different siderophores, strong iron chelates, is used as the model substances.

Journal Article↗

Quantification of hydroxamate siderophores in soil solutions of podzolic soil profiles in Sweden.

Concentrations up to 2 and 12 nM of the hydroxamate siderophores ferrichrome and ferricrocin, respectively, were identified in soil solutions of podzolic forest soils at four sites in both northern and southern Sweden. No ferrichrysin was detected. As with the dissolved organic carbon and low molecular mass organic acids, the highest concentrations of the siderophores were found in the upper layers i.e. the mor layer, the eluvial and upper illuvial horizons. At the southern sites, the concentrations of ferrichrome and ferricrocin were both of similar magnitude and did not differ between the two sites. In contrast, soil solutions at the two northern sites contained more ferricrocin than ferrichrome; the ferricrocin concentrations were also higher at the northern sites than at the southern sites. Analyses were performed by high performance liquid chromatography with a porous graphitic carbon column on which ferrichrome, ferricrocin and ferrichrysin were separated. Detection by electrospray ionization mass spectrometry (ESI-MS) combined with on-line sample pre-concentration, by means of column-switching, enabled detection limits of 0.1-0.2 nM for ferrichrome, ferrichrysin and ferricrocin. The structural identities of the siderophores were further verified by MS/MS fragmentation. Fragmentation of ferrichrome, ferricrocin and ferrichrysin occurred mainly via peptide cleavage. The most intense fragments were typified by the loss of one of the three iron(III) chelating hydroxamate residues, i.e N(5)-acyl-N(5)-hydroxy ornithine.

Chromatography, High Pressure Liquid↗

Multi-parameter investigation of tandem mass spectrometry in a linear ion trap using response surface modelling.

The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment.

Journal Article↗

Fingerprinting metal-containing biomolecules after reductive displacement of iron by gallium and subsequent column-switched LC-ICPMS analysis applied on siderophores.

Column-switching liquid chromatography followed by low-resolution ICPMS was evaluated as a tool for speciation analysis of metal-containing biomolecules. The strategy was applied on siderophores, strong iron chelators of low molecular weight (M(w) < 1500). Prior to the LC-ICPMS analysis, reductive displacement of iron by gallium was performed using ascorbate as the reducing agent to increase the sensitivity. Different experimental conditions during the exchange reaction were tested using ferrichrysin and ferrichrome for evaluation. A reaction time of 30 min and a pH of 3.9 gave an exchange yield of 27 and 83% for ferrichrysin and ferrichrome, respectively. A gradient elution profile was also developed to separate gallium-chelated siderophores on a PGC column. Detection limits for standard solutions of ferrichrysin and ferrichrome in the low-nanomolar range were obtained by monitoring the gallium-69 isotope. The combined use of LC-ICPMS and LC-ESI-MS/MS was also evaluated as a tool to identify unknown metal complexes, here siderophores, in field soil solution samples.

Ascorbic Acid↗

Novel approach to the determination of structurally similar hydroxamate siderophores by column-switching capillary liquid chromatography coupled to mass spectrometry.

In this study a new approach to determine three different siderophores (ferrichrome, ferrichrysin, ferricrocin) in natural soil solutions as well as in cultures of fungi is presented. The method includes enrichment of the analytes on a short pre-column, packed with C18 material, and subsequent highly selective separation of the analytes on a capillary porous graphitic carbon (PGC) column. In contrast to normal C18 packing materials, porous graphitic carbon offers chromatographic resolution between the three very similar analytes. The selectivity of the method is enhanced even further by the electrospray ionization (ESI) mass spectrometric detection. The combination of a short pre-column and a packed capillary separation column results in a method with high sensitivity. Reported detection limits, defined as the concentration giving the signal-to-noise ratio 3:1, is 27.7 pM for ferrichrome, 46.1 pM for ferricrocin and 37.4 pM for ferrichrysin.

Chromatography, Liquid↗