N A Mark Estes

Publications and source records attributed to N A Mark Estes.

At least 55 records · Page 3Linked to original sources

Comparison of survival and other complications after heart transplantation in patients taking amiodarone before surgery versus those not taking amiodarone.

Concern exists regarding preoperative amiodarone use and complications occurring after heart transplantation (HT). During a 10-year period of performing HT, we found that patients treated with amiodarone before undergoing HT had decreased overall survival, required longer periods of ventilatory support, and were at increased risk for significant bleeding complications. These findings raise further concern about the use of amiodarone treatment in patients with heart failure before undergoing HT.

Adult↗

Enalapril treatment and hospitalization with atrial tachyarrhythmias in patients with left ventricular dysfunction.

BACKGROUND: Experimental and clinical evidence suggests a preventive role for agiotensin-coverting enzyme (ACE) inhibitors on the development of atrial fibrillation. However, the effect of ACE inhibition on hospitalization with atrial tachyarrhythmias in patients with left ventricular (LV) dysfunction is not known. We sought to determine whether enalapril treatment reduced hospitalizations with atrial tachyarrhythmias in patients with LV dysfunction. METHODS: We performed a retrospective analysis of the Studies of Left Ventricular Dysfunction (SOLVD) trial. Hospitalizations with atrial tachyarrhythmias were noted. RESULTS: A total of 192 hospitalizations with atrial tachyarrhythmias occurred in 158 patients during a follow-up period of 34 months. The time to first hospitalization with atrial tachyarrhythmias or death was significantly lower in the enalapril group (P =.005). In a multivariate analysis adjusting for the presence of atrial fibrillation at study entry, enalapril treatment was associated with a reduction in the rate of hospitalization with atrial tachyarrhythmias or death (RR, 0.87; 95% CI, 0.79-0.96; P =.007). The incidence of hospitalization with atrial tachyarrhythmias was 7.9 hospitalizations per 1000 patient-years of follow-up in the enalapril group, compared with 12.4 per 1000 patient-years in the placebo group (RR, 0.64; 95% CI, 0.48-0.85; P =.002). CONCLUSION: Enalapril is associated with a decreased incidence of hospitalization with atrial tachyarrhythmias in patients with LV dysfunction.

Angiotensin-Converting Enzyme Inhibitors↗

Implantable cardioverter-defibrillator therapy for prevention of sudden death in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia.

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is a condition associated with the risk of sudden death (SD). METHODS AND RESULTS: We conducted a multicenter study of the impact of the implantable cardioverter-defibrillator (ICD) for prevention of SD in 132 patients (93 males and 39 females, age 40+/-15 years) with ARVC/D. Implant indications were a history of cardiac arrest in 13 patients (10%), sustained ventricular tachycardia in 82 (62%), syncope in 21 (16%), and other in 16 (12%). During a mean follow-up of 39+/-25 months, 64 patients (48%) had appropriate ICD interventions, 21 (16%) had inappropriate interventions, and 19 (14%) had ICD-related complications. Fifty-three (83%) of the 64 patients with appropriate interventions received antiarrhythmic drug therapy at the time of first ICD discharge. Programmed ventricular stimulation was of limited value in identifying patients at risk of tachyarrhythmias during the follow-up (positive predictive value 49%, negative predictive value 54%). Four patients (3%) died, and 32 (24%) experienced ventricular fibrillation/flutter that in all likelihood would have been fatal in the absence of the device. At 36 months, the actual patient survival rate was 96% compared with the ventricular fibrillation/flutter-free survival rate of 72% (P<0.001). Patients who received implants because of ventricular tachycardia without hemodynamic compromise had a significantly lower incidence of ventricular fibrillation/flutter (log rank=0.01). History of cardiac arrest or ventricular tachycardia with hemodynamic compromise, younger age, and left ventricular involvement were independent predictors of ventricular fibrillation/flutter. CONCLUSIONS: In patients with ARVC/D, ICD therapy provided life-saving protection by effectively terminating life-threatening ventricular arrhythmias. Patients who were prone to ventricular fibrillation/flutter could be identified on the basis of clinical presentation, irrespective of programmed ventricular stimulation outcome.

Adolescent↗

Use of antiarrhythmics and implantable cardioverter-defibrillators in congestive heart failure.

As much as half of the mortality in patients with congestive heart failure (CHF) resulting from left ventricular systolic dysfunction is attributable to sudden cardiac death. Thus, the identification of risk and prevention of sudden death are important components of treating this population of patients. Antiarrhythmic drugs have been shown to be either neutral or harmful when studied in patients with prior myocardial infarction and impaired left ventricular function. Amiodarone, when studied in patients with CHF, may be of benefit. This benefit may be more pronounced in patients with nonischemic cardiomyopathy. Implantable cardioverter defibrillators (ICDs) are of clear benefit when used in the primary and secondary prevention of sudden death in selected populations. Studies soon to be completed should clarify the role of the cardioverter-defibrillator in patients with CHF. Antiarrhythmic medications are often used in conjunction with ICDs for a variety of reasons. However, these drugs have the potential to adversely affect defibrillator function, and knowledge of these effects is important when using this strategy.

Anti-Arrhythmia Agents↗

Upper and lower limits of vulnerability to sudden arrhythmic death with chest-wall impact (commotio cordis).

OBJECTIVES: In an animal model of commotio cordis, sudden death with chest-wall impact, we sought to systematically evaluate the importance of impact velocity in the generation of ventricular fibrillation (VF) with baseball chest-wall impact. BACKGROUND: Sudden cardiac death can occur with chest-wall blows in recreational and competitive sports (commotio cordis). Analyses of clinical events suggest that the energy of impact is often not of unusual force, although this has been difficult to quantify. METHODS: Juvenile swine (8 to 25 kg) were anesthetized, placed prone in a sling to receive chest-wall strikes during the vulnerable time window during repolarization for initiation of VF with a baseball propelled at 20 to 70 mph. RESULTS: Impacts at 20 mph did not induce VF; incidence of VF increased incrementally from 7% with 25 mph impacts, to 68% with chest impact at 40 mph, and then diminished at >/=50 mph (p < 0.0001). Peak left ventricular pressure generated by the chest blow was related to the incidence of VF in a similar Gaussian relationship (p < 0.0001). CONCLUSIONS: The energy of impact is an important variable in the generation of VF with chest-wall impacts. Impacts at 40 mph were more likely to produce VF than impacts with greater or lesser velocities, suggesting that the predilection for commotio cordis is related in a complex manner to the precise velocity of chest-wall impact.

Animals↗

Herbal medicine: beneficial effects, side effects, and promising new research in the treatment of arrhythmias.

Herbal medications and dietary supplements are unregulated in the United States. The use of these medications has dramatically increased over the past decade. Many of these drugs are biologically active, yet physicians are often unaware their patients are using a traditional remedy. Physicians are frequently unfamiliar with the medications being used and the intended effect, as well as the side-effect profiles that accompany them. Recently, some of the herbal mediations that are commonly used in the general population have been shown to be beneficial for the treatment of arrhythmias. Unfortunately, many more have been shown to be detrimental. In this article, the background behind herbal medication and the degree to which herbal medications are being used is reviewed. Herbal medications known to have beneficial effects in the treatment of arrhythmias, as well as those that have known detrimental effects with regard to cardiac arrhythmias, are highlighted. Finally, research that has been done in this field, focusing on those compounds that have been shown to be biologically active in the treatment of cardiac arrhythmias, are reviewed.

Arrhythmias, Cardiac↗

Clinical results with catheter ablation: AV junction, atrial fibrillation and ventricular tachycardia.

With the limitations of pharmacologic and device therapies for atrial fibrillation and ventricular tachycardia, catheter ablation is assuming a larger role in the management of patients with these common arrhythmias. Multiple case series and clinical trials have helped to define the evolving role of these techniques for ablation of the atrioventricular node, atrial fibrillation, and ischemic ventricular tachycardia. Based on very low complication rates, excellent efficacy and proven outcomes with radiofrequency ablation of the atrioventricular node, this approach with permanent pacing should play a larger role in the treatment of symptomatic patients with permanent atrial fibrillation. While linear ablation of atrial fibrillation has limited clinical utility for the treatment of this common arrhythmia, the results of multiple case series of focal atrial fibrillation ablation indicate the potential for an expanding role of this curative technique. Catheter ablation techniques for ventricular tachycardia in the setting of coronary artery disease have a role as supplemental therapy to the implantable cardioverter defibrillator in patients with recurrent pharmacologically refractory ventricular arrhythmias requiring frequent device interventions.

Atrial Fibrillation↗

Frequent ICD shocks due to double sensing in patients with bi-ventricular implantable cardioverter defibrillators.

Biventricular pacing has emerged as a modality for treatment of patients with heart failure. Combined biventricular pacers and implantable cardioverter defibrillators offer treatment of heart failure as well as protection from sudden cardiac death. However, inappropriate ICD shocks as a result of double sensing due to widely spaced ventricular bipoles may pose a significant problem in these patients. We examined the ICD records of twenty-three patients with biventricular ICDs, and evaluated all episodes of double sensing that resulted in aborted or delivered therapy. In follow-up of 3.7 +/- 2.6 months, thirty-three shocks in fifteen episodes occurred in five patients (21.7%) due to double sensing. Four patients (17.4%) had aborted shocks due to double sensing. All episodes resulting in shock occurred because of sinus tachycardia or supraventricular tachycardia above the upper programmed pacing rate of the device with resultant AV conduction and double sensing of the nonpaced ventricular depolarization. In conclusion, double sensing of the R-wave is a common and clinically important cause of inappropriate ICD detection and shock in patients with biventricular ICDs. Appropriate programming of the ICD can prevent episodes of inappropriate shocks.

Aged↗

Predictors and clinical impact of atrial fibrillation after pacemaker implantation in elderly patients treated with dual chamber versus ventricular pacing.

The Pacemaker Selection in the Elderly (PASE) trial was a prospective, multicenter, single blind, randomized comparison of single chamber, rate adaptive, ventricular pacing (VVIR) with dual chamber, rate adaptive pacing (DDDR) in 407 patients aged > or =65 years(mean 76 +/- 7 years, 60% male)with standard bradycardia indications for dual chamber pacemaker implantation. The incidence, predictors, and clinical consequences of atrial fibrillation (AF) developing after pacemaker implantation in the PASE trial were studied prospectively. During a median follow-up of 18 months, AF developed in 73 (18%) patients. Kaplan-Meier estimated cumulative incidences of AF in patients with sinus node dysfunction (n=176) at 18 months were 28% in the VVIR and 16% in the DDDR groups (P=0.08). After adjustment for other clinical variables using a Cox multivariate regression model, randomization to VVIR compared with DDDR pacing mode among patients with sinus node dysfunction was independently associated with a 2.6-fold increased relative risk (RR) of developing AF after pacemaker implantation (P=0.01). Other independent clinical risk factors for development of postimplant AF included a preimplant history of hypertension (P=0.02) or supraventricular tachyarrhythmias(P<0.04). Patients who developed AF had similar health related quality of life scores and cardiovascular functional status after 18 months of pacing as patients who remained free of AF. The RR of death, stroke, or heart failure hospitalization was not increased in patients who developed AF. Thus, in the elderly patients with sinus node dysfunction requiring permanent pacing, DDDR pacing mode protected against the development of AF. However, development of AF after pacemaker implantation in this population was not associated with a significant impact on quality-of-life, functional status, or other clinical endpoints during 18 months of follow-up.

Aged↗

Automated external defibrillator arrhythmia detection in a model of cardiac arrest due to commotio cordis.

INTRODUCTION: Cardiac arrest due to chest wall blows (commotio cordis) has been reported with increasing frequency in children, and only about 15% of victims survive. Automated external defibrillators (AEDs) have been shown to be life saving in adults with cardiac arrest, but data on their use in children are limited. In a swine model of commotio cordis designed to be most relevant to young children, we assessed the efficacy of a commercially available AED for recognition and termination of ventricular fibrillation. METHODS AND RESULTS: Ventricular fibrillation was produced in anesthetized juvenile swine by precordial impact from a baseball under controlled conditions. Animals were randomized to defibrillation after 1, 2, 4, or 6 minutes of ventricular fibrillation. Twenty-six swine underwent 50 ventricular fibrillation inductions. Sensitivity of the AED for recognition of ventricular fibrillation was 98%, and specificity for nonshockable episodes was 100%. All episodes of ventricular fibrillation were successfully terminated by the AED. CONCLUSION: In this experimental model of commotio cordis, the AED proved to be highly sensitive and specific for recognition of ventricular fibrillation and effective in terminating the arrhythmia and restoring sinus rhythm. These findings suggest that early defibrillation with the AED could save young lives on the athletic field.

Animals↗

Prevalence of sensing abnormalities in dual chamber implantable cardioverter defibrillators.

BACKGROUND: The clinical efficacy of ICD therapy depends on accurate sensing of intracardiac signals and sensing algorithms. We investigated the occurrence of sensing abnormalities in patients with dual chamber ICDs. METHODS: The study group consisted of all patients with dual chamber ICDs enrolled in the LESS trial and patients implanted with dual chamber ICDs at a single center between January 1997 and July 2000. Electrograms of spontaneous ventricular arrhythmias requiring device intervention were analyzed. RESULTS: A total of 48 patients met the criteria for enrollment. Among the 244 episodes, 215 (88%) were due to ventricular tachycardia and 29 (12%) were due to ventricular fibrillation. Overall undersensing was infrequent with 12 (20%) patients exhibiting on average 2.2 undersensed beats during 26 episodes of ventricular arrhythmias. There was no delay in therapy due to undersensing. Oversensing occurred in 5 (10%) patients resulting in 13 (2.7%) episodes of inappropriate therapy. None of the patients had any lead abnormalities and oversensing resolved after device reprogramming in 4 patients while 1 patient required a separate rate sensing lead. Among patients with oversensing, 4 out of 5 were pacing before the index event while among patients with no oversensing only 5 out of 42 were pacing (P<0.001). CONCLUSIONS: Dual chamber ICDs demonstrate outstanding accuracy of sensing. However, because of the selection of patient population requiring more frequent pacing, oversensing occurs with a significant frequency. Meticulous evaluation in such patients is necessary to minimize the likelihood of oversensing and inappropriate shocks.

Aged↗

Durability of repaired sensing leads equivalent to that of new leads in implantable cardioverter defibrillator patients with sensing abnormalities.

Breaks in the insulation portions of implantable cardioverter defibrillator (ICD) leads may cause nonphysiological sensing and subsequent inappropriate ICD therapy, and may also interfere with the sensing and pacing functions of the ICD. Previously, leads with insulation breaks have been replaced with new sensing leads. However, repair of leads, utilizing a commercially available patch kit may reduce the morbidity, hospital stay, and cost of lead replacement. The long-term durability of these repairs has not previously been reported and is the subject of this study. Patients undergoing ICD sensing lead repair or replacement constituted the study population. Patients were followed at 3 month intervals with an endpoint of new lead abnormalities necessitating repeat lead repair or replacement. Twenty-five patients underwent lead repair and 27 individuals underwent lead replacement for either preoperative nonphysiological sensing (n = 25) or intraoperative evidence of insulation break (n = 27). There was no significant difference between the individuals undergoing lead repair or replacement in age (59 +/- 9 vs 60 +/- 12 years), mean left ventricular ejection fraction (40%+/- 18% vs 33%+/- 17%) or age of the lead being repaired or replaced (4.5 +/- 2.0 years vs 5.0 +/- 2.0 years). During follow-up of 44 +/- 23 months, 4 of the repaired leads and 4 of the replaced leads developed new insulation breaks requiring surgical intervention (P = 0.43). In conclusion, in nearly 4 years of follow-up of patients with sensing lead insulation breaks, there was no difference is subsequent lead survival in those with lead repair compared to those with new sensing leads inserted. The strategy of lead repair, when technically feasible, should thus be considered in all patients with sensing abnormalities secondary to insulation breaks.

Defibrillators, Implantable↗