PubMed Health⌕ Search

Biomedical subjects

N A Ricci

Publications and source records attributed to N A Ricci.

2 recordsLinked to original sources

Beck Depression Inventory--II: College population study.

This study expands on the normative data available for the newly revised Beck Depression Inventory-II. Data from both an outpatient, counseling-center sample (n = 152: 106 women, 46 men) and a classroom sample (n = 152: 79 women, 65 men) of college students are presented, including sex differences on the inventory. Means and standard deviations of individual items and total scores are reported, along with statistical tests of differences between groups. Comparisons of these data with norms reported by the authors of the inventory (Beck, Steer, & Brown, 1996) are offered. The lack of sex differences found in comparison of total scores for both samples is presented. Implications for the use of the inventory with college populations are discussed.

Adult↗

Intracoronary radiation with gamma wire inhibits recurrent in-stent restenosis.

To study the safety and efficacy of intracoronary gamma radiation delivered via a new high-activity (192)Ir source wire for the treatment of in-stent restenosis. In-stent restenosis results from neointimal tissue proliferation especially in its diffused form and presents a therapeutic challenge. Gamma radiation has been shown to decrease neointima formation within stents in animal models and in initial clinical trials. A total of 26 patients with in-stent restenosis underwent successful intervention and was treated with open-label (192)Ir using a high-activity line source. The specific activity of the source wire was 372+/-51 mCi, and the dwell time was 10.8+/-1.9 min. Primary endpoints were freedom from death, myocardial infraction (MI), and repeat target lesion revascularization (TLR) at 6 months. Secondary endpoints included angiographic restenosis and intravascular ultrasound (IVUS) neointimal hyperplasia. Procedural success was high (96.2%), and in-hospital and 30-day complications were low with no deaths, MI, or requirement for repeat revascularization. At 6 months, event-free survival was 85%: one patient required repeat PTCA, one underwent bypass surgery, and two had an MI. Baseline lesion length measured 15.77 mm. Follow-up angiography was available in 21/25 (84%) patients. The binary restenosis rates were 19.0% (4/21) in-stent and 23.8% (5/21) in-lesion. Follow-up IVUS was available in 20/25 patients. There was no increase in intimal hyperplasia from postintervention to follow-up (3.11.8 vs. 3.41.8 mm(2); P=.32). Eight patients had a reduction of neointimal intimal tissue at follow-up. These results indicate that intracoronary gamma radiation with the Angiorad source wire is safe and effective in preventing in-stent restenosis.

Adult↗