PubMed Health⌕ Search

Biomedical subjects

N Alperin

Publications and source records attributed to N Alperin.

14 recordsLinked to original sources

Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity.

The fluid that resides within cranial and spinal cavities, cerebrospinal fluid (CSF), moves in a pulsatile fashion to and from the cranial cavity. This motion can be measured hy magnetic resonance imaging (MRI) and may he of clinical importance in the diagnosis of several brain and spinal cord disorders such as hydrocephalus, Chiari malformation, and syringomyelia. In the present work, a geometric and hydrodynamic characterization of an anatomically relevant spinal canal model is presented. We found that inertial effects dominate the flow field under normal physiological flow rates. Along the length of the spinal canal, hydraulic diameter was found to vary significantly from 5 to 15 mm. The instantaneous Reynolds number at peak flow rate ranged from 150 to 450, and the Womersle number ranged from 5 to 17. Pulsatile flow calculations are presented for an idealized geometric representation of the spinal cavity. A linearized Navier-Stokes model of the pulsatile CSF flow was constructed based on MRI flow rate measurements taken on a healthy volunteer. The numerical model was employed to investigate effects of cross-sectional geometry and spinal cord motion on unsteady velocity, shear stress, and pressure gradientfields. The velocity field was shown to be blunt, due to the inertial character of the flow, with velocity peaks located near the boundaries of the spinal canal rather than at the midpoint between boundaries. The pressure gradient waveform was found to be almost exclusively dependent on the flow waveform and cross-sectional area. Characterization of the CSF dynamics in normal and diseased states may be important in understanding the pathophysiology of CSF related disorders. Flow models coupled with MRI flow measurements mnay become a noninvasive tool to explain the abnormal dynamics of CSF in related brain disorders as well as to determine concentration and local distribution of drugs delivered into the CSF space.

Anatomy, Cross-Sectional↗

Construction of a physical model of the human carotid artery based upon in vivo magnetic resonance images.

A method is described for construction of an in vitro flow model based on in vivo measurements of the lumen geometry of the human carotid bifurcation. A large-scale physical model of the vessel lumen was constructed using fused deposition modeling (a rapid prototyping technique) based on magnetic resonance (MR) images of the carotid bifurcation acquired in a healthy volunteer. The lumen negative was then used to construct a flow model for experimental studies that examined the hemodynamic environment of subject-specific geometry and flow conditions. The physical model also supplements physician insight into the three-dimensional geometry of the arterial segment, complementing the two-dimensional images obtained by MR. Study of the specific geometry and flow conditions in patients with vascular disease may contribute to our understanding of the relationship between their hemodvnamic environment and conditions that lead to the development and progression of arterial disease.

Adult↗

Improved phase-contrast flow quantification by three-dimensional vessel localization.

In this paper, a method of three-dimensional (3D) vessel localization is presented to allow the identification of a vessel of interest, the selection of a vessel segment, and the determination of a slice orientation to improve the accuracy of phase-contrast magnetic resonance (PCMR) angiography. A marching-cube surface-rendering algorithm was used to reconstruct the 3D vasculature. Surface-rendering was obtained using an iso-surface value determined from a maximum intensity projection (MIP) image. This 3D vasculature was used to find a vessel of interest, select a vessel segment, and to determine the slice orientation perpendicular to the vessel axis. Volumetric flow rate (VFR) was obtained in a phantom model and in vivo using 3D localization with double oblique cine PCMR scanning. PCMR flow measurements in the phantom showed 5. 2% maximum error and a standard deviation of 9 mL/min during steady flow, 7.9% maximum error and a standard deviation of 13 mL/min during pulsatile flow compared with measurements using an ultrasonic transit-time flowmeter. PCMR VFR measurement error increased with misalignment at 10, 20, and 30 degrees oblique to the perpendicular slice in vitro and in vivo. The 3D localization technique allowed precise localization of the vessel of interest and optimal placement of the slice orientation for minimum error in flow measurements.

Blood Flow Velocity↗

The mechanical state of intracranial tissues in elderly subjects studied by imaging CSF and brain pulsations.

The biomechanical properties of intracranial tissues influence the mechanical coupling of brain and CSF oscillations to the driving vascular pulsations. Dynamic phase contrast MRI was used to measure the transfer functions that characterize these couplings in normal elderly subjects and patients with Alzheimer's disease. The transfer functions of both groups were significantly different from the previously reported transfer functions of normal young subjects. The data show that vascular pulsations tend to cause greater spinal cord movements and smaller CSF oscillations in the older subjects than in the younger ones. These results are likely to be due to age-related changes in the mechanical state of intracranial tissues.

Adult↗

Magnetic resonance imaging of the normal temporal bone.

Recent advances in magnetic resonance imaging (MRI) technology has allowed the development of imaging sequences tailored to the assessment of exquisite anatomic detail of the temporal bone structures. This article describes MRI of the normal temporal bone anatomy, with emphasis on common anatomic variants and clinically relevant structures.

Ear, Inner↗

Assessment of the biomechanical state of intracranial tissues by dynamic MRI of cerebrospinal fluid pulsations: a phantom study.

We used a cranial phantom to investigate how intracranial mechanical factors [brain compliance and the resistance to the flow of cerebrospinal fluid (CSF)] affect the way in which CSF pulsations are driven by pulsatile transcranial blood flow. Dynamic phase-contrast magnetic resonance imaging (MRI) was used to measure the transfer function between vascular pulsations and pulsatile response of the CSF below the foramen magnum of the phantom. We found that the coupling between the high frequency components of cervical CSF flow and transcranial blood flow was decreased when the phantom was modified to simulate increased brain compliance and increased resistance to CSF flow.

Biomechanical Phenomena↗

Post-cranioplasty cerebrospinal fluid hydrodynamic changes: magnetic resonance imaging quantitative analysis.

The syndrome of the trephined has been described in many patients with cranial defects as an indication for cranioplasty. Cerebral blood flow changes, the effect of the atmospheric pressure on the brain, as well as cerebrospinal fluid hydrodynamic changes have been postulated as the possible reasons for this syndrome. Using dynamic phase-contrast magnetic resonance imaging we measured arterial, venous, and cerebrospinal fluid flow into and out of the skull, before and after cranioplasty in one patient whose bone flap was removed because of osteomyelitis. We report significant changes in the oscillatory CSF flow after cranioplasty. A moderate increase in venous outflow as well as a two-fold increase in craniocaudal cerebrospinal fluid systolic flow velocity was measured after the skull closure. The changes in the cerebrospinal fluid oscillatory flow at the level of the craniovertebral junction could reflect changes in the compliance of the craniospinal system produced by closure of the cranial defect.

Adult↗

Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI.

Brain and cerebrospinal fluid (CSF) movements are influenced by the anatomy and mechanical properties of intracranial tissues, as well as by the waveforms of driving vascular pulsations. The authors analyze these movements so that the purely hemodynamic factors are removed and the underlying mechanical couplings between brain, CSF, and the vasculature are characterized in global fashion. These measurements were used to calculate a set of impulse response functions or modulation transfer functions, characterizing global aspects of the vasculature's mechanical coupling to the intracranial tissues, the cervical CSF, and the cervical spinal cord. These functions showed that a sudden influx of blood into the head was rapidly accommodated by some type of intracranial reserve or capacity. After this initial response, an equal volume of CSF was driven through the foramen magnum over the next 200-300 ms as the intracranial reserve relaxed to its base-line state.

Adult↗

Displaying electrocorticographic findings on gyral anatomy.

Human electrocorticographic findings recorded from subdural arrays of electrodes were topographically mapped directly onto magnetic resonance images of gyral anatomy. With this technique gyri involved in generating somatosensory evoked potentials and epileptic phenomena are easily identified. Regions of the cortex which exhibit local spectral changes associated with cognitive tasks can also be visualized. These composite images of structure and function can provide insight regarding the functional organization of human cortex in relation to gyral anatomy and localized pathologic rhythms.

Brain Mapping↗

An improved method for on-line averaging and detecting of ECG waveforms.

The most widely used methods for accurate signal averaging were studied and compared in order to gain a better understanding of the qualities and performances of each method. The level-triggering, contour-limiting, and correlation methods were simulated and compared. A new correlation method which is a weighted correlation of differences proved to be most suitable for real-time signal averaging, and detection of waveforms' variations. Simulated ECG waveforms and real ECG recordings were analyzed in this study. Twenty-eight ECG recordings of unipolar leads for noninvasive detection of the His-Purkinje activity were averaged separately by each method. The success in detection and the signal to noise ratio of the detected His activity obtained by each method was compared. Simulated ECG waveforms with random noise added were analyzed by four methods and the correct alignment as a function of the noise level was measured. The performance of our method in rejection of noisy waveforms and in detection of small variations in the waveforms is demonstrated.

Electrocardiography↗

Visualization of MR angiographic data with segmentation and volume-rendering techniques.

Novel image processing and computer graphics techniques were developed to create three-dimensional (3D) models of vasculature from magnetic resonance (MR) angiographic images of the head or neck. Region growing was used to produce a mask that isolated the vascular signal in the MR angiographic data. The masked images were subjected to gradient-shaded volume rendering to create 3D views of the vasculature. The computer-derived model of intracranial vasculature was then merged with a 3D model of brain parenchyma derived from a set of MR images. The combined display of vascular and gyral anatomy may be useful for neurosurgical planning.

Brain↗

Retrospective registration of X-ray angiograms with MR images by using vessels as intrinsic landmarks.

Conventional x-ray angiography (XRA) images are projections of the vasculature with high spatial and temporal resolution, while magnetic resonance (MR) angiography (MRA) and MR imaging data show the three-dimensional locations of vessels relative to brain parenchyma. The authors have developed a retrospective method of registering these studies, which makes it practical to produce multimodality displays of this complementary information. Registration was performed by matching vessels seen on both XRA and MRA images. First, the authors determined the coordinates of the center lines of a few "landmark" vessels on the XRA image and the three-dimensional locations of the corresponding intraluminal voxels in the MRA volume. Registration was performed by rotating and translating the MRA-MR imaging volume until the perspective projection of the MRA landmark vessels matched the corresponding vessel center lines on the XRA image. Experiments with phantoms and patients indicated that the two studies were registered with an average error of less than 2 mm. A linked-cursor display was developed to show correspondence between points on the registered XRA and MRA-MR images.

Angiography↗