PubMed Health⌕ Search

Biomedical subjects

N B Cech

Publications and source records attributed to N B Cech.

6 recordsLinked to original sources

Effect of affinity for droplet surfaces on the fraction of analyte molecules charged during electrospray droplet fission.

The effect of uneven fissioning of mass and charge from electrospray droplets on the amount of analyte charged during the electrospray process was explored. A surface selectivity factor (S) was developed to describe the affinity of an analyte for the droplet surface, and both theoretical and experimental response curves were compared for analytes with various S values. The theoretical response curves were generated by calculating the overlap between the charge and analyte spawned from parent droplets to determine the amount of analyte charged. This overlap was then graphed as a function of analyte concentration. Differences in the amount of analyte charged during droplet fission were predicted for analytes of varying surface affinities. The issue of analyte partitioning between the surface and interior phases of the ESI droplet was also included in the discussion. This was accomplished by applying the equilibrium partitioning model to a set of offspring droplets to determine the amount of analyte on their surfaces and then calculating the overlap between fissioning analyte and excess charge. Experimental response curves resembled theoretical ones, and S values predicted from theory were in excellent agreement with those predicted on the basis of the structural characteristics of the analytes.

Chemical Phenomena↗

Predicting electrospray response from chromatographic retention time.

The relationship between electrospray ionization response and HPLC retention time was explored. For the series of small peptides studied, higher ESI response was observed for analytes with longer reversed-phase HPLC retention times. This correlation existed for both experimentally measured retention times and those calculated from amino acid retention coefficients. This study is useful t

Algorithms↗

Electrospray ionization detection of inherently nonresponsive epoxides by peptide binding.

A small organic molecule that is inherently nonresponsive to electrospray analysis, 1,3-butadiene diepoxide, was analyzed via electrospray ionization (ESI) by binding it to various peptides and observing the product at the characteristic mass shift. The epoxide reacted only with peptides with arginines in their sequence, most likely through a base-catalyzed ring opening to form a covalently bound product. A calibration curve linear over 3 orders of magnitude was generated for the butadiene diepoxide/peptide adduct. Several other epoxides were also reacted with the peptide of choice (angiotensin II), and adducts of these epoxides with the peptide were observed as well, demonstrating the versatility of this method for the analysis of small epoxides. This study demonstrates the possibility of assaying epoxides bound to peptides or proteins in biological samples. Furthermore, it demonstrates an important concept that could be applied to other analytical problems in electrospray: the ability to react an analyte that is nonresponsive to electrospray analysis with an analyte well suited for the technique, and accomplish quantitation based on the adduct formed between the two.

Amino Acid Sequence↗

Relating electrospray ionization response to nonpolar character of small peptides.

Nonpolar regions in biological molecules are investigated as a determining factor governing their electrospray ionization (ESI) mass spectrometric response. Response is compared for a series of peptides whose C-terminal residue is varied among amino acids with increasingly nonpolar side chains. Increased ESI response is observed for peptides with more extensive nonpolar regions. The basis for this increase is examined by comparing values of nonpolar surface area and Gibbs free energy of transfer for the different amino acid residues. Comparisons of response with octadecylamine are also made, and this highly surface-active ion is observed to outcompete all other analytes in ESI response. These observations are rationalized on the basis of the equilibrium partitioning model, which is used successfully to fit experimental data throughout the concentration range for several two-analyte systems. This model suggests that because excess charge exists on ESI droplet surfaces, an analyte's relative affinity for the droplet surface determines its relative ESI response. Increased nonpolar character, which leads to enhanced affinity for the surface phase, results in more successful competition for excess charge and higher ESI response.

Algorithms↗

Importance of gas-phase proton affinities in determining the electrospray ionization response for analytes and solvents.

The effect of gas-phase proton transfer reactions on the mass spectral response of solvents and analytes with known gas-phase proton affinities was evaluated. Methanol, ethanol, propanol and water mixtures were employed to probe the effect of gas-phase proton transfer reactions on the abundance of protonated solvent ions. Ion-molecule reactions were carried out either in an atmospheric pressure electrospray ionization source or in the central quadrupole of a triple-quadrupole mass spectrometer. The introduction of solvent vapor with higher gas-phase proton affinity than the solvent being electrosprayed caused protons to transfer to the gas-phase solvent molecules. In mixed solvents, protonated solvent clusters of the solvent with higher gas-phase proton affinity dominated the resulting mass spectra. The effect of solvent gas-phase proton affinity on analyte response was also investigated, and the analyte response was suppressed or eliminated in solvents with gas-phase proton affinities higher than that of the analyte.

Atmospheric Pressure↗

Practical implications of some recent studies in electrospray ionization fundamentals.

In accomplishing successful electrospray ionization analyses, it is imperative to have an understanding of the effects of variables such as analyte structure, instrumental parameters, and solution composition. Here, we review some fundamental studies of the ESI process that are relevant to these issues. We discuss how analyte chargeability and surface activity are related to ESI response, and how accessible parameters such as nonpolar surface area and reversed phase HPLC retention time can be used to predict relative ESI response. Also presented is a description of how derivitizing agents can be used to maximize or enable ESI response by improving the chargeability or hydrophobicity of ESI analytes. Limiting factors in the ESI calibration curve are discussed. At high concentrations, these factors include droplet surface area and excess charge concentration, whereas at low concentrations ion transmission becomes an issue, and chemical interference can also be limiting. Stable and reproducible non-pneumatic ESI operation depends on the ability to balance a number of parameters, including applied voltage and solution surface tension, flow rate, and conductivity. We discuss how changing these parameters can shift the mode of ESI operation from stable to unstable, and how current-voltage curves can be used to characterize the mode of ESI operation. Finally, the characteristics of the ideal ESI solvent, including surface tension and conductivity requirements, are discussed. Analysis in the positive ion mode can be accomplished with acidified methanol/water solutions, but negative ion mode analysis necessitates special constituents that suppress corona discharge and facilitate the production of stable negative ions.

Solvents↗