Permanent left atrial pacing with a specifically designed coronary sinus lead.

This article reports the original use of a specifically designed coronary sinus (CS) lead for permanent left atrial (LA) pacing. The device is characterized by its distal end shape featuring a double 45 degree angulation, which ensures very close contact with the CS upper wall. The device was successfully implanted in 39 out of 40 patients (97.5%). The tip electrode was eventually positioned in the distal CS in 9 patients, in the middle CS in 21 patients, and close to the ostium in the proximal CS in 9 patients. The mean acute pacing threshold voltage was 0.9 +/- 0.5 V with a mean impedance of 578 +/- 144 omega as measured in unipolar distal configuration at 0.5 ms pulse width (PW). The mean A wave amplitude was 3.5 +/- 2.1 mV. Early lead dislodgment occurred only once (3%) when the tip electrode was placed in the distal or middle CS, but more often (4/9 cases) when it was placed in the proximal CS. After a mean follow-up duration of 14 +/- 8.5 months, 35 of the 39 successfully implanted leads (89.7%) were still functional in terms of LA pacing and sensing. The mean chronic pacing threshold voltage was 1.5 +/- 0.8 V and the mean A wave amplitude was 2.7 +/- 1.6 mV. There were no lead related complications. In conclusion, the device proved to be safe and highly effective for permanent LA pacing, provided the distal tip could be positioned in the distal or middle part of the CS.

Aged↗

Clinical experience with implantable devices for control of tachyarrhythmias.

Pacing is becoming an accepted form of treatment for reentry tachycardias. The different pacing modalities available and experience with a patient-activated antitachycardia pacemaker are presented in this paper. This system has bidirectional communication between pacemaker and pacemaker-activator and between pacemaker and prescription formulator (which is a sophisticated portable stimulator used for non-invasive electrophysiological evaluation of the system). This pacemaker was implanted in 18 patients with drug-resistant tachycardias. Six patients had ventricular tachycardia, 3 had A-V nodal reentrant tachycardia, 4 had the concealed accessory pathway, and 5 had the WPW syndrome. In the 3 months before implantation the mean number of admissions for termination of tachycardia was 2.1 per patient-month. During a follow-up period of 3-26 months only 6 patients were admitted once for termination of tachycardia (0.02 admissions per patient-month). The reasons for admission of these 6 patients were: defective pacemaker activator in 2 patients, inadequate control of tachycardia in 2 patients, inappropriate use of the device in 1, and inadequate intake of medication in 1. All these problems were solved easily. Eight pacemaker activators required reprogramming, which was done in 5 patients on an out-patient basis. The interval scanning mode was used in 9 patients. Nine patients required more than 2 stimuli for reproducible termination. A step-wise increase in number of stimuli was used in 5 patients. This system has proven to be a safe and effective form of treatment of drug-resistant supraventricular and ventricular tachycardias and has resulted in marked improvement of the quality of life of these patients.

Adult↗