PubMed Health⌕ Search

Biomedical subjects

N Baldini

Publications and source records attributed to N Baldini.

At least 19 recordsLinked to original sources

Potential of FeAlCr intermetallics reinforced with nanoparticles as new biomaterials for medical devices.

Novel FeAlCr oxide dispersion strengthened intermetallics that are processed by powder metallurgy have been developed as potential biomaterials. The alloys exhibit a small grain size and a fine dispersion of yttria provides the material with a high yield strength and depending on the alloy composition good ductility (up to 5%). The biocompatibility of the alloy was assessed in comparison with commercial alumina. Saos-2 osteoblast-like cells were either challenged with mechanically alloyed particles, or seeded onto solid samples. Viability and proliferation of cells were substantially unaffected by the presence of a high concentration of particles (1 mg/mL). Solid samples of novel FeAlCr intermetallic have shown a good biocompatibility in vitro, often approaching the behavior of materials well known for their biological acceptance (e.g. alumina). It has been found that osteoblasts are able to produce ALP, a specific marker of cells with bone-forming activity. In this respect, ALUSI alloys hold the promise to be suitable substrate for bone integration. The finding of no cytotoxic effect in the presence of the alloy particles is a reliable proof of the absence of acute toxicity of the material.

Alkaline Phosphatase↗

Interferon-alpha inhibits in vitro osteoclast differentiation and renal cell carcinoma-induced angiogenesis.

Bone is a common site of osteolytic and richly vascularized metastases of renal cell carcinoma (RCC) and Interferon (IFN)-alpha based therapies have been considered for the treatment of patients affected by this disease. The effects of IFN-alpha on metastatic RCC patients have been related to its immunomodulatory, and cytotoxic activity on tumor cells, but there could be an effect also on tumor induced osteoclast differentiation and bone angiogenesis. When osteoclasts obtained from human peripheral blood mononuclear cells, cultured in the presence of receptor activator of nuclear factor-kappaB (RANKL) and macrophage-colony stimulating factor (M-CSF), were treated with IFN-alpha, the expression of bone tartrate resistant acid phosphatase (TRACP) type 5b was reduced, as well as calcium-phosphate resorption activity and expression of pro-osteoclatic transcription factor c-Fos. IFN-alpha modulation of angiogenesis was studied by analysis of proliferation, survival, and migration of a bone endothelial cell line (BBE), and by the analysis of pro-angiogenic factor expression in RCC cell lines. IFN-alpha inhibited bone endothelial cell proliferation and the expression of FGF-2, while the vascular endothelial growth (VEGF) did not show any significant variation. Moreover, IFN-alpha inhibited the migration induced by the RCC through the impairment of fibroblast growth factor-2 (FGF-2) secretion. These data demonstrate multiple activities of IFN-alpha on renal cancer-induced bone disease, in addition to its recognized role as a cytotoxic and immunomodulatory agent, because they indicate its ability to reduce bone resorption and to impair tumor-associated angiogenesis, and they also suggest the use of IFN-alpha to treat skeletal metastases of other carcinomas.

Angiogenesis Inhibitors↗

Improved osteogenic differentiation of human marrow stromal cells cultured on ion-induced chemically structured poly-epsilon-caprolactone.

The ability to control cell proliferation/differentiation, using material surface, is a main goal in tissue engineering. The objective of this study was to evaluate the attachment, proliferation and differentiation to the osteoblastic phenotype of human marrow stromal cells (MSC) when seeded on poly-epsilon-caprolactone (PCL) thin films before and after irradiation with 10 keV He+. The polymeric surface was characterized as surface chemical structure and composition, roughness and morphology on the micro- and nano-scale, wettability and surface free energy parameters. MSC were obtained from patients undergoing routine hip replacement surgery, expanded in vitro and cultured on untreated PCL and He+ irradiated PCL films for up to 4-5 weeks in osteogenic medium. He+-irradiation led to slight smoothening of the surface and different nanoscale surface chemical structure, while surface free energy resulted unchanged in comparison to untreated PCL. The results from biological testing demonstrated that early attachment and further proliferation, as well as osteoblastic markers, were higher for MSC on He+-irradiated PCL. In conclusion, the change of PCL surface properties induced by ion beam irradiation is confirmed to enhance the adhesion of MSC and support their differentiation.

Biocompatible Materials↗

Human bone marrow stromal cells: In vitro expansion and differentiation for bone engineering.

Stromal cells from marrow hold a great promise for bone regeneration. Even if they are already being exploited in many clinical settings, the biological basis for the source and maintenance of their proliferation/differentiation potential after in vitro isolation and expansion needs further investigation. Most studies on osteogenic differentiation of marrow stromal cells (MSC) have been performed using bone marrow from the iliac crest. In this study, MSC were derived from spare femoral bone marrow obtained during hip replacement surgery from 20 adult donors. After in vitro isolation the cells were grown in osteogenic medium, and their proliferation and differentiation analysed during in vitro expansion. We found that MSC isolated from the femur of adult patients consistently maintain an osteogenic potential. Using biochemical signals, these cells turn to fully differentiated osteoblasts with a predictable set of molecular and phenotypic events of in vitro bone deposition. When seeded on polycaprolactone-based scaffold or surfaces, the proliferation and mineralization of femur-derived MSC were modulated by the surface chemistry/topography. Despite remarkable differences between individual colony-forming ability, alkaline phosphatase production, and mineralization ability, these cells are a potential source for bone engineering, either by direct autologous reimplantation or by ex vivo expansion and reimplantation combined to a proper scaffold.

Adult↗

Poly-epsilon-caprolactone/hydroxyapatite composites for bone regeneration: in vitro characterization and human osteoblast response.

Polycaprolactone (PCL), a semicrystalline linear resorbable aliphatic polyester, is a good candidate as a scaffold for bone tissue engineering, due to its biocompatibility and biodegradability. However, the poor mechanical properties of PCL impair its use as scaffold for hard tissue regeneration, unless mechanical reinforcement is provided. To enhance mechanical properties and promote osteoconductivity, hydroxyapatite (HA) particles were added to the PCL matrix: three PCL-based composites with different volume ratio of HA (13%, 20%, and 32%) were studied. Mechanical properties and structure were analysed, along with biocompatibility and osteoconductivity. The addition of HA particles (in particular in the range of 20% and 32%) led to a significant improvement in mechanical performance (e.g., elastic modulus) of scaffold. Saos-2 cells and osteoblasts from human trabecular bone (hOB) retrieved during total hip replacement surgery were seeded onto 3D PCL samples for 1-4 weeks. Following the assessment of cell viability, proliferation, morphology, and ALP release, HA-loaded PCL was found to improve osteoconduction compared to the PCL alone. The results indicated that PCL represents a potential candidate as an efficient substrate for bone substitution through an accurate balance between structural/ mechanical properties of polymer and biological activities.

Alkaline Phosphatase↗

Evaluation of bone healing enhancement by lyophilized bone grafts supplemented with platelet gel: a standardized methodology in patients with tibial osteotomy for genu varus.

Orthopedic practice may be adversely affected by an inadequate bone repair that might compromise the success of surgery. In recent years, new approaches have been sought to improve bone healing by accelerating the rate of new bone formation and the maturation of the matrix. There is currently great interest in procedures involving the use of platelet gel (PG) to improve tissue healing, with satisfactory results both in vitro and in maxillofacial surgery. Otherwise, to our knowledge, only a preliminary clinical study was undertaken in the orthopedic field [Kitoh et al., Bone 2004;35:892-898] and the efficacy of PG is still controversial. Our paper focuses on the effect on bone regeneration by adding PG to lyophilized bone chips used for orthopedic applications. The clinical model and the laboratory methodology were standardized. As a clinical model, we employed the first series of patients of a randomized case-control study undergoing high tibial osteotomy (HTO) for genu varus. Ten subjects were enrolled: in 5 patients lyophilized bone chips supplemented with PG were inserted during tibial osteotomy (group A); 5 patients were used as a control (group B) and lyophilized bone chips without gel were applied. Forty-five days after surgery, computed tomography scan guided biopsies of grafted areas were obtained and the bone maturation was evaluated by a standardized methodology: the osteogenic and angiogenic processes were semi-quantitatively characterized by using histomorphometry, and the mineral component of the lyophilized and host bone was analyzed by using X-ray diffraction technique with sample microfocusing and microradiography. Lyophilized bone with PG seems to accelerate the healing process, as shown by new vessel formation and deposition of newly formed bone, with no evidence of inflammatory cell infiltrate, when compared with lyophilized bone without gel. On the contrary, lyophilized bone undergo a resorption process, and a fibrous tissue often fills the spaces between chips. A histiocytic/giant-cell reaction is sometimes present. Otherwise, no differences have been found concerning microstructure. Our findings show the reliability of the methodology used to monitor early bone repair. The completion of the study and the evaluation of the ultimate clinical outcome are necessary in order to verify PG in vivo effects in orthopedic surgery.

Adult↗

In vivo study on the healing of bone defects treated with bone marrow stromal cells, platelet-rich plasma, and freeze-dried bone allografts, alone and in combination.

The repair of confined trabecular bone defects in rabbits treated by autologous bone marrow stromal cells (BMSC), platelet-rich plasma (PRP), freeze-dried bone allografts (FDBA) alone and in combination (BMSC + PRP; FDBA + BMSC; FDBA + PRP; FDBA + PRP + BMSC) was compared. A critical size defect was created in the distal part of the femurs of 48 adult rabbits. Histology and histomorphometry were used in the evaluation of healing at 2, 4, and 12 weeks after surgery. The healing rate (%) was calculated by measuring the residual bone defect area. Architecture of the newly formed bone was compared with that of bone at the same distal femur area of healthy rabbits. The defect healing rate was higher in PRP + BMSC, FDBA + PRP, FDBA + BMSC, and FDBA + PRP + BMSC treatments, while lower values were achieved with PRP treatment at all experimental times. The highest bone-healing rate at 2 weeks was achieved with FDBA + PRP + BMSC treatment, which resulted significantly different from PRP (p < 0.05) and BMSC (p < 0.05) treatments. At 4 weeks, the bone-healing rate increased except for PRP treatment. Finally, the bone-healing rate of FDBA + PRP, FDBA + BMSC, and FDBA + PRP + BMSC was significantly higher than that of PRP at 12 weeks (p < 0.05). At 12 weeks, significant differences still existed between PRP, BMSC, and FDBA groups and normal bone (p < 0.05). These results showed that the combination of FDBA, BMSC and PRP permitted an acceleration in bone healing and bone remodeling processes.

Animals↗

Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up.

Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed. Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured. There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous.

Adult↗

A preliminary in vitro and in vivo study of the effects of new anthraquinones on neutrophils and bone remodeling.

Osteolysis, that is, progressive periprosthetic bone loss, is responsible for approximately 70% of aseptic loosening and implant failure. Usually, it is due to a granulomatous reaction wear-induced, leading to macrophage and osteoclast-mediated bone resorption. At present, there is no established prophylaxis or treatment for this process. For this purpose, as a preliminary investigation, we aimed to study the effects in two directions, inhibition of proinflammatory signals, and bone remodeling activity, of two newly synthesized anthraquinone molecules [N,N'-Diethylamino-2,6-anthraquinone-disulfonamide (GR375) and N,N'-(p-ethoxyphenyl)-2,6-anthraquinone-disulfon amide (GR377)]. Among the pro-inflammatory signals, the ability of the two anthraquinones to interfere with the production of superoxide anion (O(2) (-)), which was assumed as a marker of reactive oxygen species (ROS), was evaluated in an in vitro cell model by testing phagocytes, such as human neutrophils, challenged by the chemotactic agent N-formylmethionyl-leucyl-phenylalanine (FMLP). Both compounds inhibited O(2) (-) production, in a dose-dependent way, without exerting scavenger effects. An in vivo model was applied to investigate their effect on bone remodeling. Fifty-four female Wistar rats were divided into eight groups of six animals each, and a 4-week treatment was applied in two phases. A 25 mg/kg/os dose in the first phase and 12.5-6.25 mg/kg/os doses in the second one were employed. The tibia trabecular bone at the secondary spongiosa level was analyzed, and trabecular bone volume (%TBV), trabecular thickness (TbTh), and apatite lattice parameters were measured. At the highest doses of GR375 and GR377 the %TBV and the TbTh increased by 33.2, 34.6%, and 3.6 and 9.1%, respectively, whereas crystallographic parameters were not significantly different from the untreated group. Our results suggest a simultaneous antiinflammatory and antiosteoclastic activity of both drugs that encourages to perform further research. If it will be confirmed, they could be proposed in a variety of bone diseases, in particular, when acute inflammation is associated to osteolytic processes and, eventually, in the prevention and treatment of periprosthetic osteolysis.

Animals↗

Quantitative assessment of the response of osteoblast- and macrophage-like cells to particles of Ni-free Fe-base alloys.

In the present study, the effect of mechanically alloyed particles of new FeAlCr alloys developed for potential applications as surgical implants has been tested on osteoblast- and macrophage-like cells and compared to particles of the Ti6Al4V alloy, for which there is a good clinical experience. After microstructural characterisation of the particles, cells were cultured with particles for 24-48 h using three different concentrations of particles, and the response of cells was quantified by assessment of viability, proliferation, and morphology. Mineralisation by osteoblasts was verified after 21 days. The amount of aluminium and chromium ions in the culture medium of macrophages was measured by graphite furnace atomic absorption and phagocytosis of particles assessed by light microscopy. Viability and proliferation of osteoblast- and macrophage-like cells were substantially unaffected by the presence of particles of the new alloys, which were phagocytosed according to their size. Aluminium and chromium ions were released in the culture medium, but no direct correlation with the cell behaviour was found. In vitro mineralisation was achieved by osteoblasts in due time. The new alloys are well tolerated in in vitro systems, and, due to their chemical and mechanical characteristics, they are under development for surgical implants.

Alloys↗

Evaluation of mechanical properties and biological response of an alumina-forming Ni-free ferritic alloy.

PM 2000 is a Ni-free oxide dispersion strengthened Fe-20Cr-5Al alloy able to develop a fine, dense and tightly adherent alpha-alumina scale during high-temperature oxidation. Despite the high temperature involved during thermal oxidation (1100 degrees C), microstructural changes in the candidate material, a hot rolled product, hardly occurs. Consequently, the good mechanical properties of the as-received material are not significantly affected. Moreover, due to the high compressive residual stresses at the alumina scale, an increase in the fatigue limit from 500 to 530 MPa is observed. Such stresses also account for the high capability of the coating/metal system to withstand more than 1% tensile deformation without cracking. The biocompatibility of the alloy was assessed in comparison to commercial alumina. Saos-2 osteoblast-like cells were either challenged with PM 2000 particles, or seeded onto PM 2000 (with and without scale) solid samples. Viability, growth, and ALP release from cells were assessed after 3 or 7 days, while mineralization was checked at 18 days. This study has demonstrated that PM 2000 with and without scale are capable of supporting in vitro growth and function of osteoblast-like cells over a period of 18 days. Results from this study suggest that the resulting alumina/alloy system combines the good mechanical properties of the alloy with the superior biocompatibility of the alpha-alumina, for which there is very good clinical experience.

Aluminum Oxide↗

Systemic cross-linked N-terminal telopeptide and procollagen I C-terminal extension peptide as markers of bone turnover after total hip arthroplasty.

There is no diagnostic, non-invasive method for the early detection of loosening after total hip arthroplasty. In a pilot study, we have analysed two serum markers of bone remodelling, procollagen I C-terminal extension peptide (PICP) and cross-linked N-terminal telopeptide (NTx), as well as the diagnostic performance of NTx for the assessment of osteolysis. We recruited 21 patients with loosening (group I), 18 with a well-fixed prosthesis (group II) and 17 at the time of primary arthroplasty for osteoarthritis (OA) (group III). Internal normal reference ranges were obtained from 30 healthy subjects (group IV). The serum PICP level was found to be significantly lower in patients with OA and those with loosening, when compared with those with stable implants, while the NTx level was significantly increased only in the group with loosening, suggesting that collagen degradation depended on the altered bone turnover induced by the implant. This hypothesis was reinforced by the finding that the values in the pre-surgery patients and stable subjects were comparable with the reference range of younger healthy subjects.A high specificity and positive predictive value for NTx provided good diagnostic evidence of agreement between the test and the clinical and radiological evaluations. The NTx level could be used to indicate stability of the implant. However, further prospective, larger studies are necessary.

Adult↗

Effects of activated platelet concentrates on human primary cultures of fibroblasts and osteoblasts.

BACKGROUND: Platelet alpha granules contain growth factors released into the surrounding environment during activation. This property has been used in clinical medicine to accelerate the repair process by activating in vitro autologous platelets with thrombin and has also been proposed to promote the proliferation of bone cells. The aim of this research was to assess the effect of platelet concentrates activated with thrombin on human gingival fibroblasts and human osteoblasts from trabecular bone. METHODS: Platelet concentrates, activated with bovine thrombin, were added to the cells in serum-free medium. The cultures were assessed for proliferation by vital stain and cell count after 72-hour incubation. Alkaline phosphatase activity was tested after 72-hour incubation on the osteoblast lysates by a colorimetric assay. After 21 days the formation of mineral nodules was tested in the osteoblast cultures by alizarin red staining. The effects of the activated platelet concentrates (APC) were compared with the serum-free medium (SF), or with platelet-poor plasma added medium (PPP). RESULTS: The fibroblast growth in the presence of APC was higher, though not significantly, than SF. APC resulted in a nonsignificant decrease in proliferation and alkaline phosphatase expression in osteoblasts, compared both to serum free medium, and PPP. Mineralization was only modestly increased after incubation with APC in comparison with serum-free medium. CONCLUSIONS: There were no statistical differences in fibroblast proliferation, or in osteoblast growth and functions between serum-free conditions and the platelet gel treatment. Therefore, neither fibroblast proliferation nor osteoblast growth and functions were affected by the activated platelet concentrates in vitro.

Alkaline Phosphatase↗

Diagnosis of infection after total hip replacement.

Subclinical infection in patients with pain following total hip replacement (THR) is an underestimated condition that needs consideration because it mimics aseptic loosening, contributes to periprosthetic osteolysis, and necessitates proper treatment. We aimed to define the reliability of diagnostic parameters that are routinely used before revision surgery for the assessment of infection. A continuous series of 26 subjects who underwent THR revision surgery was considered, including 21 cases diagnosed as aseptic loosening (group A) and 5 hip revisions with a clinical diagnosis for infection (group B). Seven subjects at the time of the primary arthroplasty were used as negative controls (group C). Technetium-99m labeled hydroxymethylene diphosphonate [(99m)Tc-HDP]- and technetium-99m hexamethylpropyleneamine oxide [(99m)Tc-HMPAO)]-labeled granulocyte scintigraphy, histology of peri-implant tissues, laboratory tests for inflammation, and microbiology were performed. Scintigraphy was positive for loosening [positive (99m)Tc-HDP scan] but negative for infection [negative (99m)Tc-HMPAO-labeled granulocyte scan] in all group A patients, whereas in 11 cases (52%) a positive culture was unexpectedly obtained. Histology showed conflicting results: Polymorphonuclear cells (PMNs) were found only in 5 of 11 culture-positive patients, whereas in 2 cases the presence of PMNs did not correspond to a positive culture. In group B patients, both isotope scans and microbiology were found to be positive. All control subjects (group C) had negative cultures. In our opinion, smoldering infection could be present in a significant proportion of cases of failed hip implants currently diagnosed as "nonseptic." The inflammatory response to wear debris and the presence of superimposed, slowly growing bacteria could act synergically, both contributing to the pathogenesis of periprosthetic osteolysis.

Adult↗

The influence of alumina and ultra-high molecular weight polyethylene particles on osteoblast-osteoclast cooperation.

Particle-induced macrophage activation, mainly by UHMWPE wear, has been recognized as the biological mechanism leading to periprosthetic bone resorption, which is responsible for the loosening of the total hip replacements (THR). Ceramic-on-ceramic implants have been advocated as a means of reducing wear products. Many studies investigated the effect of alumina (Al(2)O(3)) particles on monocytes/macrophages, but only limited information are available on their participation to bone turnover. An in vitro model was performed to investigate how Al(2)O(3) and UHMWPE particles may influence the osteoblast-osteoclast interaction: human osteoblasts (HOB) were obtained from trabecular bone, while osteoclasts were derived from peripheral blood mononuclear cells (PBMC) of healthy donors. The amount of IL6, TNF alpha, GM-CSF, and other factors acting on the bone turnover, i.e. the 'receptor activator of NF kappa B' ligand (RANKL) and osteoprotegerin (OPG), was detected in culture medium of particle-challenged HOB (HOB-CM). The Al(2)O(3) and UHMWPE particles did not affect either cell viability or TNF and GM-CSF release, while the increase in IL6 release seemed to be dependent on the particle concentration. UHMWPE increased the release of RANKL from HOB, while OPG and OPG-to-RANKL ratio were significantly inhibited. The ability of HOB-CM to promote osteoclastogenesis was tested via osteoblast/monocyte cooperation: after seven days of culture UHMWPE HOB-CM induced a large amount of multinucleated TRAP-positive giant cells, as well as significantly reduced the amount of IL6, GM-CSF and RANKL in the supernatant. With regard to the inductive effect on the osteoclastogenesis, our results show that the Al(2)O(3) wear debris are less active.

Aluminum Oxide↗

Reversal of multidrug-resistance using Valspodar (PSC 833) and doxorubicin in osteosarcoma.

High-grade osteosarcoma is an extremely aggressive neoplasm, where over 80% of patients present with life-threatening micrometastases at diagnosis. Systemic control of the disease is therefore critical for the treatment of these patients and neoadjuvant chemotherapy using various drugs, including doxorubicin (DXR), which has been demonstrated to be the most effective regimen. Multidrug resistance (MDR) to some anticancer agents, including DXR, mediated by the MDR1 gene product P-glycoprotein (Pgp), has been shown to be a major cause of chemotherapy failure in osteosarcoma. We analyzed the effect of a cyclosporine A derivate Valspodar (PSC 833) on MDR human osteosarcoma cells. We also evaluated Pgp expression in sporadic appendicular canine osteosarcoma. Moreover, dogs were treated with combined administration of DXR and PSC 833. Several blood samples were collected for the determination of DXR and PSC 833 levels. PSC 833 induced a complete reversal of the resistant phenotype at concentrations compatible with the clinical use. Pgp was present in 12/18 (66.6%) of the cases. At the time of DXR administration, adequate blood concentrations of PSC 833, to provide a complete MDR reversal, were obtained without clinical or laboratory findings of toxicity. Combination therapy with DXR and PSC 833 allowed a 30% decrease in DXR dose infusion with equivalent therapeutic exposure. The high incidence of Pgp expression in osteosarcoma confers to the study a rationale for an effective regimen based on down-modulation of MDR.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Biologic effects of surface roughness and fluorhydroxyapatite coating on osteointegration in external fixation systems: an in vivo experimental study.

The concomitant influence of surface roughness and fluorhydroxyapatite (FHA) coating of titanium (Ti) implants on bone response was investigated. For this purpose, titanium screw-shaped implants with a lower degree (Y371) and a higher degree (TiPore300) of surface roughness, coated with FHA and uncoated, were transversally inserted into the diaphyses of sheep tibiae for 12 weeks. Four sheep received Y371 (group A) and Y371 + FHA (group B) screws and four sheep received TiPore300 (group C) and TiPore300 + FHA (group D) screws. For each type of material, the morphology and microstructure of implant-facing bone were evaluated. The host bone of each tibia was used as a control. In all groups the bone tissue did not reach a complete maturation. The higher degree of roughness, perhaps due to an excessive irregularity of the surface, induced the worst osteointegration: a fibrous tissue layer between screw and new bone tissue was often present. Nevertheless, as viewed by XRD, no crystallographic change of the apatite lattice was observed in any of the implants. In contrast, the microhardness value, an index of bone mineralization, was higher in the uncoated screws and decreased progressively in the following order: group C > group A > group B > group D. The association of plasma spraying with roughness treatment constitutes a complex system that seems to interfere with bone mineralization. A chemical change of the surface, perhaps with more Ti release or more coating degradation, could be responsible for such impairment. The authors emphasize the necessity for simultaneous evaluation of surface topography and chemistry as well as an improvement in plasma-spraying and post-processing techniques and in standard procedures for materials characterization.

Animals↗

Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results.

The use of metallic heads articulating with metallic cups could solve the problem of polyethylene (PE) wear in total hip replacement (THR) with metal-on-PE bearings. A conspicuous release of metal ions from new models of metal-on-metal bearings has been found in the short-term, but it is yet unclear whether the medium-term corrosion rate is high or, on the contrary, it becomes negligible, because of the continuous surface finishing. Our purpose was to compare the serum ion values (nanograms per milliliter) in 15 patients with metal-on-metal stable prosthesis (Group A), in the short-term (subgroup A(1); mean follow-up: 24 mo) and medium-term (subgroup A(2); mean follow-up: 52 mo), in order to determine whether the ion release decreased with time of implant. Chromium (Cr), cobalt (Co), molybdenum (Mo) and aluminum (Al) were analyzed. Twenty-two presurgical patients were used for comparison (Group B). The reference range was obtained from a population of 27 healthy subjects (Group C). Co and Cr levels in the medium-term (subgroup A(2)) were not decreased in comparison with the short-term values (subgroup A(1)) and were significantly higher (p < 0.001) than presurgical and reference values. Otherwise, Mo and Al concentrations were not significantly increased in comparison with reference values. In conclusion, despite the apparent advantage of metal-on-metal coupling, especially in younger patient populations, there is a major concern about the extent and duration of the relevant "internal" exposure to Cr and Co ions. This exposure should be carefully monitored, in order to clarify the biologic effects of ion dissemination and, consequently, to identify risks concerning long-term toxicity of metals.

Adult↗