PubMed Health⌕ Search

Biomedical subjects

N Barthe

Publications and source records attributed to N Barthe.

13 recordsLinked to original sources

Cellulose phosphates as biomaterials. In vivo biocompatibility studies.

Femoral implantation of regenerated cellulose hydrogels revealed their biocompatibility, but a complete osseointegration could not be observed. Phosphorylation was therefore envisaged as the means to enhance cellulose bioactivity. In vitro studies showed that regenerated cellulose hydrogels promote bone cells attachment and proliferation but do not mineralize in acellular simulated physiological conditions. On the contrary, phosphorylated cellulose has shown an opposite behavior, by inducing the formation of a calcium phosphate layer in simulated physiological conditions, but behaving as a poor substrate for bone cells attachment and proliferation. In order to investigate the in vivo behavior of these materials, and assess the influence of mineralization induction ability vs. bone cells compatibility, unmodified and phosphorylated cellulose hydrogels were implanted in rabbits for a maximum period of 6 months and bone regeneration was investigated. Despite the difficulties arising from the retraction of cellulose hydrogels upon dehydration during the preparation of retrieved implants, histological observations showed no inflammatory response after implantation, with bone intra-spongious regeneration of cells and the integration of the unmodified as well as the phosphorylated cellulose implants. After a maximum implantation period of 6 months, histological observations, histomorphometry and the measurement of the amount of 45Ca incorporated in the surrounding tissue indicated a slightly better osseointegration of phosphorylated cellulose, although no significant differences between the two materials were found.

Animals↗

Energy expenditure following oral glucose load in ten uremic patients before and after three months on a ketoacid-supplemented very-low-protein diet.

We have previously shown that a ketoacid-supplemented very-low-protein diet (KSVLPD), which has been proposed to slow down the rate of progression of chronic renal failure (CRF), improves tissue insulin sensitivity and decreases hyperinsulinemia in predialytic uremic patients. However, this diet may interfere with nutritional status. The aim of this study was to study basal energy expenditure (EE) and EE after an oral glucose load in patients with CRF before and during a KSVLPD (0.3 cal x kg wt(-1) x d(-1) supplemented with aminoacid and ketoanalogs) using oral glucose loading in combination with indirect calorimetry. We also monitored body weight and analyzed body composition by dual-energy x-ray (DEXA) during KSVLPD. In the third month of KSVLPD, no significant change in total body weight was observed, but DEXA showed a decrease in lean tissue mass (LTM; 46.2 +/- 3.6 kg before v 44 +/- 3.4 kg in the third month; P <.01) and an increase in body fat mass (20.1 +/- 2.4 kg before v 21.3 +/- 2.4 kg on KSVLPD; P <.05). Postabsorptive plasma glucose level was significantly lower, and glucose oxidation and energy expenditure per LTM were significantly increased (EE, 20 +/- 0.8 cal x kg LTM(-1) x min(-1) before diet v 21.9 +/- 1.1 cal x kg LTM(-1) x min(-1) after 3 months on KSVLPD; P <.01). Plasma glucose and serum insulin levels were significantly lower after glucose loading, and glucose oxidation increased. EE values were significantly higher after the oral glucose load, and cumulative EE after oral load increased from 20.7 +/- 0.7 cal x kg LTM(-1) x min(-1) before the diet to 22.9 +/- 1.1 cal x kg LTM(-1) x min(-1) in the third month of KSVLPD; P <.001). Glucose oxidation was higher and cumulative glucose storage was decreased after diet (29.6 +/- 4.2 g v 20.9 +/- 3.4 g on KSVLPD; P <.01). We conclude that KSVLPD increases EE in the postabsorptive state and after an oral glucose load with an adaptation of lean tissue mass in the third month of the diet. Therefore, during KSVLPD, strict monitoring of dietetic management is necessary to maintain energy requirements at high levels appropriate to the new EE.

Administration, Oral↗

No change of hyperleptinemia despite a decrease in insulin concentration in patients with chronic renal failure on a supplemented very low protein diet.

Chronic renal failure (CRF) is often accompanied by hyperleptinemia caused by deficient renal metabolism of leptin and possibly increased leptin production, which in turn may result from the hyperinsulinemia and increased proinflammatory cytokine levels in patients with CRF. The hyperinsulinemia and insulin resistance observed in patients with CRF improve on supplemented very low protein diets (SVLPDs). The goal of our study is to determine whether the correction of hyperinsulinemia and insulin resistance in patients with CRF by SVLPDs is accompanied by improvement in hyperleptinemia. Thirteen patients were studied before and 1 year after following SVLPDs providing 0.3 g/kg/d of protein, supplemented with amino acids and ketoanalogues. After 1 year, patients showed markedly less hyperinsulinemia (7.4 +/- 1.6 versus 13.8 +/- 2 microU/mL at the start of diet; P: = 0.05) and insulin resistance, whereas serum leptin levels remained unchanged (16.1 +/- 4.7 versus 19.1 +/- 7.4 ng/mL at start of the study; P: = not significant). The initial correlation between serum leptin level and percentage of body fat persisted during follow-up. No correlation was found between insulin and leptin levels or between the variation of these two parameters during the study. Our study shows that the correction of hyperinsulinemia and insulin resistance in patients with CRF by SVLPDs is not accompanied by improvement in hyperleptinemia, which consequently does not appear to result from changes in carbohydrate metabolism.

Dietary Proteins↗

Outcome of nutritional status and body composition of uremic patients on a very low protein diet.

Concern has been raised about the nutritional adequacy of a very low protein diet (VLPD). Monthly clinical evaluation by a physician and dietitian and quarterly dietary records, anthropometric measurements, blood testing, and dual energy X-ray absorptiometry (DEXA) were used to assess the course of nutritional status for 1 year in 10 clinically stable patients (six men, four women; age, 57.1 +/- 9.3 years) with advanced chronic renal failure (mean glomerular filtration rate, 13.2 +/- 4.8 mL/min/1.73 m(2)). These patients received a VLPD providing 0.3 g/kg/d of protein and were supplemented with amino acids and ketoanalogues. Conventional nutritional markers remained unchanged after 1 year of the VLPD. However, during the same period, whole-body DEXA showed a significant decrease in lean tissue from 46.2 +/- 10.2 to 45.0 +/- 9. 8 kg (P < 0.02); limb-trunk lean tissue ratio was reduced from 0.86 +/- 0.12 to 0.82 +/- 0.12 (P < 0.02), total-body fat increased from 20.0 +/- 6.9 to 21.4 +/- 7.0 kg (P < 0.05), and the percentage of total-body fat increased from 29.2% +/- 8.7% to 31.7% +/- 8.8% (P < 0.03). These different modifications occurred abruptly during the first 3 months, then stabilized or slightly improved thereafter. These mild changes do not appear to be deleterious given the favorable long-term outcome of these patients, even after they began treatment by dialysis or after renal transplantation.

Absorptiometry, Photon↗

Bone mass and dynamic parathyroid function according to bone histology in nondialyzed uremic patients after long-term protein and phosphorus restriction.

One year of a very low protein diet (VLPD) can reverse secondary hyperparathyroidism in uremic patients. We studied bone histology, bone mineral density (BMD), and dynamic parathyroid function (calcium/PTH curves) in 16 nondialyzed patients with advanced renal failure who had been receiving a VLPD for a mean of 5 yr (mean protein intake, 0.34 +/- 0.12 mg/kg x day; mean phosphorus intake, 8.2 +/- 2.1 mg/kg x day) and daily supplementation with essential amino acids and their ketoanalogs (1000 IU vitamin D2 and 1-2 g calcium carbonate). Three patients exhibited a high bone formation rate (BFR), 7 patients had normal bone remodeling, and 6 patients had a low BFR, including 2 with osteomalacia and 4 with adynamic bone disease without aluminum overload. A longer diet duration and lower caloric intake were associated with low BFR. More than half of the patients exhibited moderate or severe osteoporosis at the appendicular skeleton. The t score of femur BMD explained 65% of the BFR variance. Patients with a low BFR had a dynamic parathyroid function similar to that of patients with a normal BFR, except they had a lower capacity to buffer a calcium load, whereas patients with a high BFR had a higher basal PTH/maximum PTH and a steeper calcium/PTH curve slope; the calcium set-point was identical in the three groups.

Adult↗

Optimization of a new scintillation gas detector used to localize electrons emitted by 99mTc.

UNLABELLED: We have developed a scintillation gas detector to localize electrons emitted by 99mTc. This type of detector allows direct quantification of images and so provides a clear advantage over autoradiographic film. We have optimized the device to give an image spatial resolution that closely approximates that of typical autoradiographic film. To improve this resolution, it was necessary to select only low-energy electrons (2 and 15 keV) and to devise novel detection and localization techniques for the ionizing particles. METHODS: A parallel-plate proportional avalanche chamber is subject to a uniform electrical field and amplifies the number of released electrons through collisions of ionizing particles in the gas mixture. Light emitted by the gas scintillator during the avalanche process is collected by a highly intensified charge coupled device camera. The centroid of each resulting light distribution is calculated, resulting in a quantitative mapping of the sample's activity. Insertion of the sample within the gas volume improves the efficiency and so provides a method that is both very sensitive and linear. RESULTS: We have shown that in a parallel-plate structure, the application of a high electrical field to the surface of the sample and the selection of appropriate light spots, according to their morphology, can overcome localization errors due to the particles' trajectories. We have obtained a resolution of the order of 30 microm, using electrons from 99mTc. CONCLUSION: This detection technique allows considerable improvement in image resolution. This "electron camera" is a serious rival to existing autoradiographic techniques, because it provides certain other advantages, including direct quantification, linearity, high dynamic range and low noise levels. Thus, new perspectives are made available in quantitative double tracer autoradiography, because electrons can be selected for imaging as a function of their energy.

Animals↗

Measurement of bone mineral density in mother-daughter pairs for evaluating the family influence on bone mass acquisition: a GRIO survey.

The relative influence of genetic and environmental determinants on bone mass is still unclear. Using an original multicentric mode of recruitment, based on absorptiometry current practice, the hypothesis of a familial predisposition to low bone mineral content was assessed. The study was based on dual-energy X-ray absorptiometry (DXA) measurements of lumbar and femoral neck bone mineral density (BMD), using daughters of women with a low BMD (case mothers). These BMD values were compared with those of control daughters of women with a normal BMD. Case mothers (n = 72) aged 54.3 +/- 4.8 years were recruited on the basis of a questionnaire and a vertebral Z-score < -2 SD. Their healthy daughters of more than 20 years (n = 77) aged 28.2 +/- 4.9 years had their vertebral and femoral BMD Z-score determined. The control groups were composed of mothers aged 54.1 +/- 4.7 years, paired by age +/- 2 years to the case mothers, and of their daughters of more than 20 years old, aged 27.7 +/- 5.8 years. For daughters, a significant difference was found between the mean vertebral Z-scores (-0.82 +/- 1.08 for cases and 0.01 +/- 1.14 for controls, p < 0.0001). The difference was in the same direction but was not statistically significant for mean femoral Z-scores (-0.58 +/- 1.15 for cases and -0.22 +/- 1.33 for controls, p < 0.073). These findings confirm the hypothesis of a familial predisposition to low BMD.

Absorptiometry, Photon↗

Comparison of two Hologic DXA systems (QDR 1000 and QDR 4500/A).

Bone mineral content is reliably measured by dual energy X-ray absorptiometry (DXA), if manufacturers' recommendations and quality control (QC) procedures are followed. Several phantoms (Hologic anthropomorphic spine phantom, the Groupe de Recherche et d'Informations sur les Osteoporoses (GRIO) test objects and the European semi-anthropomorphic phantoms) were used to evaluate reproducibility, linearity, accuracy and spatial resolution of two DXA devices in vitro. These parameters were also evaluated in vivo from measurements performed on 120 volunteer patients. It was found that when one device (a single beam monodetector QDR 1000) is replaced by another (a fan beam multidetector QDR 4500/A), the novel combination of procedures described here, ensures that the accuracy of DXA study results is maintained when both devices are used in succession for the same patient. To study the possible responses in clinical situations, the influence of bone environment (soft and adipose tissues) was also evaluated. In both systems, similar performances (in vitro coefficients of variation of 0.5%) were established. At extreme bone density values, slight differences in linearity were found, as well as differences in accuracy and spatial resolution. Lumbar spine and femoral neck measurements were performed with both systems in 120 volunteers, both measurements being made on the same day. The corresponding bone mineral density (BMD) values were highly correlated (r2 = 0.985 for lumbar spine and 0.948 for the femoral neck), and the mean BMD differences were 0.68% and 0.37% for each anatomical site, respectively. Although small, these differences add to the precision error of the method, which is near 1%. A calibration curve has to be obtained in order that both devices can be equally used in regular clinical study. We concluded that when a DXA system is replaced by a new one, appropriate QC procedures must be strictly observed.

Absorptiometry, Photon↗

Evolution of the local calcium content around irradiated beta-tricalcium phosphate ceramic implants: in vivo study in the rabbit.

To evaluate whether dissolved calcium from tricalcium phosphate implants contributes to osseous wound healing in bone defects, the authors used nuclear radioactivated materials. Six months after irradiation, the calcium was still radioactive. Samples of the material were prepared and placed in rabbit condyles for 1, 3 and 9 months. Over time the condyles were retrieved and treated for histology or radiocounting. Measurements of the radioactivity of the slices and histomorphometry of the implants and surrounding tissues were performed. The authors observed that the radioactivity decreased regularly. Connective tissue had penetrated the pores and totally invaded the implants, first at the periphery of the implants, then inside the pores. Comparison of the results of radioactivity and histomorphometry suggest that part of the calcium from the implants was re-used specifically in the new osseous tissue.

Animals↗

[Bone remodeling assessment after total hip replacement].

It is known that total hip arthroplasties (THA) lead to adaptative remodeling changes resulting in periprosthetic bone loss. DEXA is recognized as the most precise and accurate method for quantifying bone mineral density (BMD) in humans. The present study compares over two years after THA, DEXA data to those of urinary deoxypyridinoline (uDPYR), a pyridinium crosslink of bone collagen fibrils proven to be a reliable bone resorption marker. 41 patients (21 postmenopausal female, 20 male) underwent cemented THA. Urinary excretion of DPYR was determined using ACS : 180 SE (Bayer Diagnostics) and normalized for creatinine excretion while periprosthetic BMD (g/cm2) was measured (QDR 4500, Hologic), at post-operative day, 3 months, 1 year and 2 years after surgery. The 7 periprosthetic subregions (R1-R7) of the Gr en method are the regions of interest for evaluating bone remodeling process. uDPYR showed a significant decrease between postoperation and 1 year: 10.6 0.80 vs 4.8 0.6 nmol/mmol, p < 0.0001 (Wilcoxon Test for paired samples and statistical significance accepted at p < 0.05) and non significant variation between 1 and 2 years. Between post-operation and 3 months global and regional BMDs decrease significantly (p < 0.04) followed by an increase in distal BMD (R3, R4, R5). During the second year BMD increases also for other regions. At 2 years BMD in distal regions is recovered except in the proximal R7 when comparing post-operation and 2 years, pattern consistent with literature. Thus, a discrepancy is observed between uDPYR and DMO results that does not allow us to use a bone resorption urinary marker to monitore local bone periprosthetic remodeling.

Adult↗