PubMed Health⌕ Search

Biomedical subjects

N Bian

Publications and source records attributed to N Bian.

5 recordsLinked to original sources

Differential pulse voltammetric indirect determination of aluminium in drinking waters, blood, urine, hair, and medicament samples using L-dopa under alkaline conditions.

The differential pulse voltammetric (DPV) indirect determination of aluminium using L-dopa under alkaline conditions on a glassy carbon working electrode was studied. The proposed method relies on the linear decrease of the DPV anodic peak current of L-dopa with increase in the concentration of aluminium added. Under the optimum experimental conditions (pH 8.5, 0.08 M NH4Cl-NH3.H2O buffer solution, and 4 x 10(-4) M L-dopa), the linear range is 2-18 x 10(-7) M AlIII. The detection limit is 7.6 x 10(-8) M and the relative standard deviation for 8 x 10(-7) M AlIII is 3.5% (n = 8). A number of foreign species were examined as potential interferents. The method was applied to the determination of aluminium in drinking waters, synthetic renal dialysate, sodium chloride injection, sucrafate, hydrothorax, blood, urine and hair samples. The physiological significance is discussed.

Aluminum↗

N-hydroxysuccinimide ester labeling 5'-aminoalkyl DNA oligomers: reaction conditions and purification.

Difficulties were encountered in labeling 5'-aminoalkyl DNA oligomers with glycolketo electrophore N-hydroxysuccinimide esters in aqueous sodium bicarbonate (a common base for this purpose), followed by C18-silica reversed-phase high-performance liquid chromatography (HPLC) to achieve purification. The electrophore-labeled oligomers were not separated readily either from the hydrolyzed electrophore or from the starting oligomer. This problem was overcome by conducting the reaction with triethylamine as a base, organic washing the reaction mixtures after evaporation, and separating on a C18-poly(styrene-divinylbenzene) HPLC packing.

Acetonitriles↗

Electrophore mass tag dideoxy DNA sequencing.

Toward a goal of dideoxy sequencing DNA utilizing electrophore labels, we prepared four electrophore-labeled DNA oligonucleotide primers. Each primer has a different electrophore and DNA sequence but a common glycol keto (alpha,beta-dihydroxyketo) release group. Cleavage of this latter group by either periodate oxidation or a thermal retroaldol reaction releases the electrophores for detection by mass spectrometry. Successful sequencing data with these primers was obtained by capillary electrophoresis on an ABI Model 310 after fluorescence dideoxy terminator cycle sequencing reactions were conducted. In a separate experiment, it was demonstrated that a cocktail of the four electrophore DNA primers could be detected as a dried sample spot by CO2 laser desorption/capillary collection/gas chromatography electron capture mass spectrometry. These results establish some feasibility for our long-term goal of high-speed multiplex electrophore mass tag dideoxy DNA sequencing. Ultimately we plan to use a higher number of electrophore mass tags and to rely on direct detection of the desorbed electrophores by electron capture time-of-flight mass spectrometry.

Chromatography, High Pressure Liquid↗

Electron-capture detection: difluorobenzyl and related electrophores.

Difluorobenzyl derivatives (several isomers were tested) of 4-hydroxyacetophenone were synthesized and found to have similar properties (retention and response) by both reversed-phase HPLC and GC-ECD relative to each other, and also relative to that of a corresponding conventional pentafluorobenzyl derivative. The same was true for a representative difluorobenzyl derivative of thymine and 1-naphthoic acid. Overall, the responses by GC-ECD for the same core structure were only about two- to four-fold lower for a difluorobenzyl compared to a corresponding pentafluorobenzyl derivative. This makes a difluorobenzyl derivative attractive as an HPLC-UV retention marker, and sometimes as a substitute for a pentafluorobenzyl derivative (to help overcome an interference) in a method based on detection by electron capture. We also observed, somewhat as an aside, that the GC-ECD response of the benzyl derivative of 4-hydroxyacetophenone was only seven-fold lower than that of the corresponding pentafluorobenzyl derivative, and that this former benzyl derivative gave a 2.10(4) higher response than acetophenone. Thus, replacing the ring hydrogen atoms of a benzyl group with fluorine atoms had a relatively small impact on both the hydrophobicity and electron capture properties of the compounds tested here.

Chromatography, Gas↗

Detection via laser desorption and mass spectrometry of multiplex electrophore-labeled albumin.

Albumin was reacted with a mixture of six electrophore N-hydroxysuccinimide esters, each of which possessed an interior glycolketo linkage. The purpose of this linkage is to release the attached electrophore as a ketone when heated, due to a thermal retro-aldol reaction. The multiplex electrophore-labeled albumin was detected as a dried spot deposited on a polyimide membrane by laser desorption/capillary collection (of the released ketone electrophores)/off-line gas chromatography/electron capture-mass spectrometry. This encourages further study of such electrophore labels in immunoassays and related techniques, where there is a need to make advances in multi-analyte detection.

Albumins↗