Absorption and scatter of encapsulated gas filled microspheres: theoretical considerations and some measurements.

Albunex is an ultrasound contrast agent for use in echocardiology and other areas. It is capable of passing the lung circulation after intravenous injection. A theoretical model is developed for some acoustic properties, particularly the scatter and absorption, of this contrast agent, considering the individual microspheres as air bubbles surrounded by a thin shell. The attenuation, the sum of absorption and scatter, of this contrast medium is measured with five transducers to cover the frequency range from 700 kHz to 8.5 MHz. It is concluded that the model correlates well with these acoustic measurements. When Albunex is used intravenously the backscatter enhancement in the left ventricle is caused mainly by the microspheres with diameters between 5 and 8 microns.

Acoustics

Electrical impedance of layered atherosclerotic plaques on human aortas.

Electrical impedance measurements were performed on 13 atherosclerotic human aortic segments at 67 measuring spots in order to determine whether or not on the basis of these data a distinction can be made between atherosclerotic lesions and normal tissue. Stenosis localization and guidance of interventional techniques could be among the applications of an impedance measuring technique implemented on a catheter system. The experimental results, obtained with a two-electrode measuring technique, show that the apparent resistivity of an atherosclerotic spot does not necessarily deviate much from the resistivity of normal tissue. This is clarified by histology which shows that the majority of lesions has a surface layer of connective, fibrous tissue having almost similar conducting properties as the normal arterial wall. For gaining a deeper understanding of the way in which the measured data come about, a physical model of an atherosclerotic lesion is presented and confronted with the data. Both experimental data and theoretical considerations lead to the conclusion that only when the superficial fibrous layer is absent or very thin in relation to the size of the measuring electrode, the measured resistivity at a lesion is much higher than at normal spots. This occurs as a consequence of the high ohmic properties of the calcified or lipid deposits in the atherosclerotic lesion.

Aortic Diseases

Assessment of medial thinning in atherosclerosis by intravascular ultrasound.

This study investigated the in vitro (40 MHz) and in vivo (30 MHz) feasibility of intravascular ultrasound to document the influence of atherosclerotic lesions on the typical 3-layered appearance of muscular arteries. The in vitro images of 39 arteries were compared with the corresponding histologic sections. Media and lesion thickness were measured at the areas of minimal and maximal lesion thickness. The median media thickness was 0.8 mm in the absence of a lesion, decreasing to 0.3 mm in the area of maximal atherosclerosis. The ultrasonic data correlated closely with histologic measurements (0.6 and 0.3 mm, respectively). The in vivo study was performed in 29 patients undergoing coronary or peripheral vascular procedures. A total of 150 still-frames were selected for quantitative analysis. The median media thickness was 0.6 mm in the absence of a lesion, decreasing to 0.1 mm in the area with maximal atherosclerosis. This study revealed that intravascular ultrasound imaging accurately determines that media thickness of muscular arteries is inversely related to lesion thickness. In vitro data, verified with histology, can be translated to humans in vivo.

Arteries

Assessment of arterial disease and arterial reconstructions by intravascular ultrasound.

Clinical application of intravascular ultrasound to assess arterial atherosclerotic disease was introduced in humans after extensive in vitro and in vivo animal studies. Real-time images, obtained with a 30 MHz element mounted on a 5 F catheter, consistently confirmed angiographic images, up till now considered to be the gold standard. In addition to these data, ultrasonic cross-sectional imaging provided information on the composition of atheroselectic lesions and the size and shape of the lumen. Based on the experimentally derived criteria for tissue characterization, a better insight into arterial morphology could be obtained, allowing improved planning of interventional or reconstructional procedures. Moreover intravascular ultrasound has proved valuable as a post-interventional procedure to monitor and assess the quality of interventional results. The ultrasound images are clearly superior to angiographic studies, albeit the ultrasonic information is an adjunct to angiography and, as yet, not a substitute. We present our initial experience with intravascular ultrasound obtained in patients with substantial peripheral arterial disease.

Angioplasty, Balloon

Imaging of post-mortem coronary arteries by 30 MHz intravascular ultrasound.

Intravascular ultrasound cross-sectional imaging of the atherosclerotic artery may be employed to guide plaque ablation by spark erosion, atherectomy, laser irradiation or other means. To assess whether in the coronary artery the echolucent zone of the three-layered ultrasound appearance of muscular arteries might be a reliable boundary to halt transluminal ablative angioplasty, epicardial coronary arteries were scanned under pressure over a distance of 4-8 cm at 1 mm intervals. A 5.2F catheter with a 30 MHz transducer rotating at 600 RPM was used. In 419 images from four post-mortem hearts, aged at death 22, 31, 56 and 82 years, the presence of a distinct echolucent zone was scored as percentage of the wall circumference. The median scores were 0%, 0%, 10% and 75%, respectively. In the three youngest hearts, the three-layered appearance was largely absent. In the 82 year old heart, in contrast, the three-layered appearance could generally be identified. Within subjects, the presence of an echolucent zone was variable in location. Qualitatively, neither abundant medial elastin tissue nor a reduced medial thickness could explain the absence of an echolucent zone when the ultrasound image was compared to the corresponding microscopic section. The results show that in the 82 year old heart, 30 MHz intravascular ultrasound discrimination of coronary wall layers would be adequate to guide transluminal plaque ablation. In the younger hearts, guided ablation would fail due to the limited presence of a distinct echolucent zone as an ultrasound landmark of the media. Whether the presence or absence of an echolucent zone is related to age remains to be determined.

Adult

Backscatter directivity and integrated backscatter power of arterial tissue.

A 27 MHz transducer, mounted on an ultrasonic microscope, was used to quantify the dependence of backscatter power on the angle of incidence of arterial vessels. Due to variations in the angle of incidence significant variations in backscatter power were found in the intima, the muscular and elastic media, the adventitia and the external elastic lamina. The muscular and the elastic media show anisotropic behaviour in their angle dependence, i.e. the extent of the angle dependence depends on the direction of angle variation. This anisotropic nature is probably caused by the dominant orientation of smooth muscle cells or elastin fibers in these tissue layers. Measurements on 13 specimens of the iliac artery showed that each tissue type of the vessel has its own specific angle dependent behaviour. In the future this property might be used for quantitative tissue characterization.

Humans

Principles and recent developments in ultrasound contrast agents.

The behaviour of gas bubbles and gas encapsulated spheres as echographic contrast agents is reviewed. Compared with rigid spheres, gas bubbles are superior scattering agents and they offer a number of useful properties which can be exploited in a variety of ways. The analysis of their velocity of sound, back-scatter intensity, second harmonic emission and resonant frequency opens up new perspectives in the development of contrast agents for echocardiographic research with potential clinical applications.

Contrast Media

The relative contributions of myocardial wall thickness and ischemia to ultrasonic myocardial integrated backscatter during experimental ischemia.

The purpose of this study was to assess the empirical relationship between myocardial integrated backscatter (IB) and myocardial wall thickness (WT) in normal myocardium. A second object was to estimate the additional contribution to acute ischemic integrated backscatter levels given this relationship. Myocardial IB measurements and simultaneous myocardial WT measurements were made in 16 open-chested pigs with intact coronary circulation (normal myocardium) and 10 min after the flow in the left anterior descending coronary artery had been reduced to 20% of its baseline value (ischemic myocardium). Measurements were made 50 times during one cardiac cycle and averaged over 10 cardiac cycles. IB and WT measurements were normalized with respect to the nonischemic end-diastolic values. The relationship between IB and WT in normal myocardium was estimated in every individual pig by simple linear regression. Estimates of IB during ischemia were calculated on the basis of this relationship and the ischemic WT measurements. Differences of the estimator and the actual measurement made during ischemia depict the actual contribution of the state of acute ischemia, without the influence of WT. The slope of the relationship between IB and WT during normal myocardial contraction ranged from -0.16 to 0.03 dB/% (mean = -0.036 dB/%, SD = 0.06 dB/%). The additional contribution of ischemia ranged from -3.84 to 5.56 dB (mean = 0.31 dB, SD = 2.72 dB). It was concluded that the average contribution of ischemia to IB measurements is insignificant if the IB dependency on WT is removed from the data and that the higher level of ischemic IB measurements can be explained by the decrease in wall thickness during ischemia and not by the ischemia itself.

Animals

Influence of attenuation on measurements of ultrasonic myocardial integrated backscatter during cardiac cycle (an in vitro study).

The purpose of this study was to investigate the dependence of ultrasonic integrated backscatter (IB) and attenuation in myocardium on wall thickness in a state of acute ischemia. Therefore, an in vitro experiment was set up in which attenuation, IB and wall thickness of a piece of freshly excised myocardium could be measured almost simultaneously. The myocardium was taken from 11 Yorkshire pigs (25-30 kg) that were killed less than 45 min before the experiment. The myocardium was placed in the far field of an ultrasound transducer (3.2-7.2 MHz) and then compressed by a stainless steel sphere. Data were processed off-line. Backscatter and attenuation were also measured as a function of frequency at 100% and 75% wall thickness, respectively. Both attenuation and IB varied during compression. Attenuation had an initial value of 2.19 +/- 0.76 dB/cm and a slope of 0.015 +/- 0.017 dB/cm% wall thickness. IB had an initial value of -76.9 +/- 2.7 dB and a slope of -0.12 +/- 0.07 dB/% wall thickness. After subtracting the influence of the attenuation from the IB the initial value of IB was -74.0 +/- 2.7 dB and the slope -0.08 +/- 0.07 dB/% wall thickness. Attenuation appeared to have a linear dependency on frequency. Backscatter appeared not to increase with increasing frequency without correction of the spectrum for the frequency dependent insonified volume.

Animals

Cyclic changes of blood echogenicity in high-frequency ultrasound.

Ultrasound images from human arteries obtained in vivo with an intravascular 30 MHz ultrasound imaging device show that blood echogenicity changes during the cardiac cycle. Quantitative measurements of blood echogenicity during the cardiac cycle suggest that these variations may be related to changes in the state of erythrocyte aggregation, which are induced by varying shear rate.

Blood Flow Velocity

Angle-dependent backscatter from the arterial wall.

The anisotropic nature of intra-arterial echographic images is reported, and the source of this anisotropy is investigated using postmortem human iliac arteries. A 27 MHz transducer, mounted on an ultrasonic microscope, is used to quantify the angular dependence of the backscatter power versus the angle of incidence, and these results are correlated with histological findings. Besides the observed differences in the acoustic response of morphologically different tissues, significant variations in backscatter power are found in both media and internal elastic lamina due to variations in the angle of incidence. This angle dependence is caused by the dominant orientation of fibers in tissue layers and by the shape and size various scattering particles. The results indicate that long microscopic structures with one main orientation are responsible for the backscattered signal and that the angular-dependent response is related to the histologically determined orientation of these fibers. These results may have an impact on the assessment of intra-arterial echographic images.

Blood Vessels

Ultrasonic myocardial integrated backscatter and myocardial wall thickness in animal experiments.

The purpose of this study was to distinguish between normal and ischemic myocardium using ultrasonic integrated backscatter (IB) measurements and to relate IB with myocardial wall thickness. IB was measured in 9 open-chested Yorkshire pigs (24-30 kg) before, after 30 minutes of partial occlusion of the proximal left anterior descending coronary artery (LADCA), and after 60 minutes of subsequent reperfusion. The ultrasound transducer (4 MHz) was sutured onto the epicardial surface perfused by the LADCA. IB measurements were made with a repetition rate of 50 times per heart rate simultaneously with a left ventricular pressure signal. Myocardial wall thickness was measured off-line. The measurements of integrated backscatter, left ventricular pressure and wall thickness were based on mean values of ten subsequent cardiac cycles. End-systolic IB measurements were 5.3 dB higher during occlusion as compared to the reference measurements (7.1 +/- 3.2 dB versus 1.8 +/- 2.6 dB; p = 0.002). No statistically significant differences were found in end-systolic IB measurements. End-systolic wall thickness was 5 mm smaller during occlusion as compared to the reference measurements (7.2 +/- 1.4 mm versus 12.2 +/- 1.2 mm; p less than 0.001). Simple linear regression analysis showed a statistically significant inverse relationship between IB measurements and wall thickness in 21 out of the 23 sequences in which wall thickness could be measured. End-systolic IB measurements are favourable to distinguish acute ischemic myocardium from normal myocardium. There is a distinct inverse relationship between IB and myocardial wall thickness.

Animals

Enhanced morphological diagnosis in infective endocarditis by transoesophageal echocardiography.

Thirty three consecutive patients with clinically suspected endocarditis were studied by both precordial cross sectional echocardiography and transoesophageal echocardiography. The diagnostic value of both techniques was assessed. The data were compared with findings at operation in 25 patients. In 21 patients with native valve endocarditis precordial echocardiography showed evidence of vegetations in six patients and suggested their presence in nine. Transoesophageal echocardiography identified vegetations in 18 patients. Complications were seen in four patients at precordial echocardiography and in nine patients at transoesophageal echocardiography. Precordial echocardiography did not show vegetations in any of the 12 patients with prosthetic valve endocarditis whereas transoesophageal echocardiography showed vegetations in four. Complications were seen in four patients at precordial echocardiography and in 10 at transoesophageal echocardiography. Echocardiographic findings were confirmed at operation in all 25 operated patients. In two patients both echocardiographic techniques had missed the perforation of the cusps of the aortic valve that was seen at operation, but this had no effect on patient management. Transoesophageal echocardiography is the best diagnostic approach when infective endocarditis is suspected in patients with either native or prosthetic valves.

Adolescent

The design, construction and clinical evaluation of a small phased array transducer for intraoperative echocardiography.

A small probe for cardiac surgery was developed and clinically tested. The probe is built as a phased array transducer with 64 elements with a centerfrequency of 5 MHz. The transducertip is connected with a handle by a flexible yet steerable shaft. This shaft has a length of 10 cm and can be set in a desired shape. Good quality images were obtained in all patients. The first study suggest many applications for a small probe in intraoperative echocardiography.

Cardiac Surgical Procedures

Early and recent intraluminal ultrasound devices.

The history of intraluminal echography dates back to the very beginning of diagnostic ultrasound. Over the years many fascinating ideas and applications of catheter tip or gastroscopic tube tip mounted transducers have been described. This chapter surveys these methods, subdividing them into a) measurements; b) Doppler and c) imaging. The survey ranges from early work of Cieszynski on the feasibility of echocardiography to more recent intra-arterial catheter tip Doppler with guidewire and balloon as described by Serruys. Examples of ultrasound catheter tip echography in combination with other techniques such as angioscopy, laser ablation and spark erosion are also described. Today practical approaches are limited to imaging only. The three major approaches for catheter tip echo imaging are described and compared. This paper concludes with the results of automatic contour analysis of the inner arterial boundaries.

Cardiac Catheterization

Intravascular echographic assessment of vessel wall characteristics: a correlation with histology.

In vivo application of intravascular high frequency ultrasonic imaging for peripheral and coronary artery disease is a promising technique for vascular surgeons, radiologists and cardiologists. This report demonstrates in vitro results obtained with a high frequency imaging catheter (40 MHz) in 70 human specimens including arteries with and without atherosclerosis, veins, coronary artery bypass grafts and vascular prosthetic material. Correlation between the ultrasonic images and the histologic characteristics of the corresponding vessel wall tissue and lumen geometry was established. In addition, the effect of intervention techniques i.e. balloon angioplasty, spark erosion and laser were studied with ultrasound and histology. It is anticipated that development of such a catheter imaging technique has potential for diagnostic imaging and for combination with therapeutic systems.

Angioplasty, Balloon