PubMed HealthSearch

Biomedical subjects

N C Nanda

Publications and source records attributed to N C Nanda.

At least 19 recordsLinked to original sources

Usefulness and limitations of transesophageal echocardiography in the assessment of proximal coronary artery stenosis.

To assess the usefulness of transesophageal echocardiography in the evaluation of proximal coronary artery stenosis, 111 consecutive patients (mean age 61 years) who had intraoperative transesophageal echocardiography and coronary angiography within 1 week of surgery were studied. Transesophageal echocardiography visualized the entire length of the left main artery (0.2 to 2.2 cm, mean 0.93), 0.2 to 2.2 cm of the proximal left anterior descending artery and 0.1 to 3.4 cm of the proximal left circumflex artery in 103 patients (93%) and 0.1 to 4.6 cm of the proximal right coronary artery in 55 patients (49%). In the coronary artery segments visualized by echocardiography and compared with the corresponding angiographic segments, transesophageal echocardiography correctly identified 23 (96%) of 24 left main stenoses, 11 (78%) of 14 stenoses involving the left anterior descending artery, 6 (75%) of 8 left circumflex stenoses and all 7 stenoses (100%) of the right coronary artery. In all seven patients with ostial stenosis (left main artery in five and right coronary artery in two), the condition was correctly diagnosed by this technique. The sensitivity and specificity of transesophageal echocardiography in the overall evaluation of proximal coronary artery stenosis as customarily defined by angiography were 96% and 99% for the left main artery, 48% and 99% for the left anterior descending artery, 67% and 100% for the left circumflex artery and 37% and 100% for the right coronary artery, respectively. The distance of the stenotic lesion from the origin of the vessel by transesophageal echocardiography also correlated well with that measured by angiography (r = 0.63 to 0.99).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Nonsurgical closure of femoral pseudoaneurysms complicating cardiac catheterization and percutaneous transluminal coronary angioplasty.

OBJECTIVES: This study was performed to describe the initial experience and follow-up of ultrasound-guided compression of pseudoaneurysms in patients receiving systemic anticoagulant or antiplatelet therapy, or both, after recent cardiac catheterization or percutaneous transluminal coronary angioplasty. BACKGROUND: Femoral artery pseudoaneurysm formation after an interventional procedure is becoming more common as larger caliber catheters and prolonged anticoagulant and antiplatelet therapy are being used. Traditional treatment of this complication has been surgical repair. This study describes a new method of closing femoral pseudoaneurysms by using external compression guided by Doppler color flow imaging. METHODS: Fifteen patients, 3 undergoing cardiac catheterization and 12 undergoing coronary angioplasty, developed an expansile groin mass at the vascular access site diagnosed as a femoral artery pseudoaneurysm by Doppler ultrasound. Seven of the patients had undergone coronary stenting and were receiving postprocedural anticoagulant therapy. These patients underwent progressive graded mechanical (C-clamp) external compression guided by ultrasound. The mechanical compression was titrated to obliterate the vascular tracts to these aneurysms and maintain adequate flow in the femoral artery. RESULTS: After an average compression time of 30 min (range 10 to 120), these tracts remained closed. Follow-up ultrasound examination at 24 h or later confirmed continued closure in all. CONCLUSIONS: This study suggests that nonsurgical closure of femoral pseudoaneurysms is feasible. This technique may be valuable in managing vascular access-related complications after diagnostic and interventional procedures, even in patients requiring prolonged anticoagulant therapy.

Adult

Transesophageal echocardiographic diagnosis of multicentric left ventricular myxomas mimicking a left atrial tumor.

We report a case of multicentric left ventricular myxomas with prolapse of one myxoma into the left atrium during ventricular systole that mimicked a left atrial tumor. The transthoracic echocardiogram showed large masses in the region of the mitral valve leaflets consistent with vegetations or tumors. A computed tomographic scan of the chest demonstrated two distinct left atrial masses, one of which appeared to prolapse from the left atrium into the left ventricle. Intraoperative transesophageal echocardiography showed a large pedunculated mass moving between the two left-sided cardiac chambers with intermittent trapping of the mass in the left atrium. The mass was attached to the left ventricular posteromedial papillary muscle by a long stalk. Another adjacent large ventricular mass was also noted in the left ventricle. These findings were confirmed at operation, which also demonstrated a third small tumor arising from the atrial aspect of the posterior mitral leaflet.

Adult

Value and limitations of color Doppler echocardiography in the evaluation of percutaneous balloon mitral valvuloplasty for isolated mitral stenosis.

The limitations of 2-dimensional and pulsed Doppler echocardiography in patients undergoing mitral valvuloplasty are well known. This study was undertaken to assess the value of color Doppler flow imaging in 36 symptomatic mitral stenosis patients who subsequently underwent successful balloon mitral valvuloplasty by comparing the results to those obtained at cardiac catheterization. Color Doppler-guided conventional Doppler assessment agreed well with cardiac catheterization results in classifying mitral stenosis as mild, moderately severe and severe, both before and after valvuloplasty. Color Doppler was also useful in identifying patients who had moderate to severe mitral regurgitation before and after valvuloplasty. Color Doppler flow mapping was more sensitive than oximetry in the detection of iatrogenic atrial septal defects, which were noted in 25 patients. The defects of those patients with smaller defects by color Doppler (diameter less than 0.7 cm) or echocardiographic shunt volume less than 0.7 liters/min tended to close, usually within 6 months, as opposed to those with larger defects or higher shunt volumes, which tended to persist. Echocardiographic shunt volumes revealed a fair correlation with oximetric results.

Cardiac Catheterization

Uses and limitations of transthoracic echocardiography in the assessment of atrial septal defect in the adult.

Two-dimensional and color Doppler echocardiography accurately detected the presence of an atrial septal defect (ASD) in 47 of 50 adults (mean age 40 years) confirmed by surgery or cardiac catheterization, or both. It correctly categorized all patients with ostium secundum and ostium primum ASD but misdiagnosed 3 of 5 patients with surgically proven sinus venosus ASD. The shunt flow volume across the ASD was calculated with the standard Doppler equation, and assuming the ASD to be circular correlated with shunt flow volume obtained by cardiac catheterization (r = 0.74). The maximum width of the color flow signals moving across the ASD was taken as its diameter. Mean flow velocity was determined either by placing a pulsed Doppler sample volume parallel to the flow across the ASD as visualized by color Doppler or by color M-mode examination, which allowed determination of flow velocities using a previously validated method that incorporates a computer analysis of pixel color intensity. The pulmonary to systemic blood flow ratio obtained by color-guided conventional Doppler interrogation of the left and right ventricular outflow tracts correlated poorly with cardiac catheterization results (r = 0.38). In patients with associated tricuspid regurgitation, the peak systolic pulmonary artery pressure obtained by color Doppler-guided continuous-wave Doppler correlated well with that obtained at cardiac catheterization (r = 0.89). The maximum color Doppler jet width of the flow across the ASD poorly correlated with ASD size estimated at surgery (r = 0.50).

Adolescent