PubMed Health⌕ Search

Biomedical subjects

N C van de Merbel

Publications and source records attributed to N C van de Merbel.

11 recordsLinked to original sources

Mass balance study of [14C] rabeprazole following oral administration in healthy subjects.

The study was designed to determine the excretion balance of radiolabeled rabeprazole in urine and feces and to examine the metabolite profile in plasma, urine and feces after a single oral dose of [14C] rabeprazole, preceded by once daily dose of rabeprazole for 7 days. Six healthy subjects were enrolled in this study. The study was a single-center, open-label, multiple-dose, mass-balance study. Each subject received a single 20 mg dose of rabeprazole tablet for 7 days followed by the administration of 20 mg of [14C] rabeprazole as an oral solution after an overnight fast on Day 8. After oral dosing of [14C] rabeprazole, the mean Cmax of total radioactivity was 1,080 +/- 215 ng equivalent/ml with 0.33 +/- 0.13 hours of the mean tmax. The apparent elimination half-life of total [14C] radioactivity was 12.6 +/- 3.4 hours. The total [14C] recovery in urine and feces was 99.8 +/-0.7% by 168 hours after oral administration of [14C] rabeprazole, and mean cumulative [14C] radioactivity excreted in urine was 90.0 +/- 1.7% by 168 hours and 79.8 +/- 2.5% of the radioactivity was excreted in urine within 24 hours. Excretion via feces added to the total by 9.8%. The major radioactive component in the early plasma samples was rabeprazole, however the thioether and thioether carboxylic acid metabolites were the main radioactive components in the later plasma sample. These results support the previous finding that the substantial contribution of the non-enzymatic thioether pathway minimizes the effect of CYP2C19 polymorphism on the inter-individual variation ofplasma clearance of rabeprazole compared with other PPIs. Low levels of the sulfone metabolite were detected only in early plasma samples. No rabeprazole was detected in any urine and feces samples. The main radioactive components in urine were thioether carboxylic acid and mercapturic acid conjugate metabolites, and in the feces, the thioether carboxylic acid metabolite. The administration of [14C] rabeprazole was safe as evidenced by the lack of serious adverse events and the fact that all observed events were mild in intensity. [14C] rabeprazole was rapidly absorbed after oral administration and mostly excreted in urine.

2-Pyridinylmethylsulfinylbenzimidazoles↗

Experiences with monolithic LC phases in quantitative bioanalysis.

The applicability of monolithic liquid chromatographic (LC) phases in the field of quantitative bioanalysis has been evaluated. Two existing methods with fluorescence detection (the determination of bexarotene in plasma and the determination of dextromethorphan plus metabolites in urine) were successfully transferred from a conventional reversed-phase column to a 10 cm x 4.6 mm i.d. monolith. By simply increasing the mobile phase flow-rate, run times were about 3-fold reduced, while the chromatographic resolution of the analytes remained unaffected. In both cases, a very good correlation was found between the results of clinical samples obtained with the original method and those obtained with the adapted method. Two methods with tandem mass spectrometric detection were set up. For one of these methods (nifedipine in plasma), the separation of the analyte from interfering matrix components did not need a high plate number; the resolution found on a 10-cm monolith at 6 ml/min and that on a 3-cm conventional column at 2 ml/min were comparable and achieved in the same period of time. As the validation results on both column types were similar and considering the limited compatibility of mass spectrometric detection with high solvent flow rates, the conventional column was concluded to be the best choice for this application. For the determination of estradiol in plasma, however, there was so much interfering material that needed to be separated from the analyte, that the best results were obtained with three 10-cm monolithic columns coupled in series and because of the possibility to apply a relatively high flow-rate, a reasonable run time was still achieved.

Chromatography, Liquid↗

Validated method for the determination of risperidone and 9-hydroxyrisperidone in human plasma by liquid chromatography-tandem mass spectrometry.

Since the first entry of risperidone on to the market in the early 1990s, investigation of the pharmacokinetic behaviour of the compound for which the availability of a bioanalytical method was a condition sine qua non, has received considerable attention. Most of the published methods, however, did not reach the level of sensitivity and selectivity which can be obtained today since the evolution of liquid chromatography-tandem mass spectrometry (LC-MS-MS) towards a routine technique in the bioanalytical laboratory. Therefore, we developed and validated a new LC-MS-MS method for the determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma. This paper describes in detail the bioanalytical procedure and summarizes the validation results obtained. In addition, it focuses on the pitfalls one might encounter when developing similar assays. Despite the particular physicochemical characteristics of risperidone and 9-hydroxyrisperidone, the LC-MS-MS method enabled the quantification of both compounds down to 0.1 ng/ml. The method uses a sample preparation step by solid-phase extraction at pH 6 using a mixed-mode phase. In a short chromatographic run, separation of 9-hydroxyrisperidone from the minor metabolite 7-hydroxyrisperidone is achieved. Detection takes place by (turbo)ionspray tandem mass spectrometry in the positive ion mode. The validated concentration range is from 0.100 to 250 ng/ml, using 500 microliter of sample, with accuracy (bias) and precision (coefficient of variation) being below 15%. Although new developments in equipment will allow us to further improve and speed up the method, the assay reported can be used as a routine method to support a wide range of pharmacokinetic studies.

Antipsychotic Agents↗

Validated liquid chromatographic method for the determination of bexarotene in human plasma.

A new liquid chromatographic method is described for the determination of the anti-tumour agent bexarotene in human plasma over the range 0.500-1500 ng/ml, using 1 ml of sample. Sample preparation consists of liberating the analyte from plasma lipids by adding acetonitrile, followed by acidification of the plasma and liquid extraction using a mixture of isoamyl alcohol and pentane or hexane. Separation and quantitation are performed by reversed-phase column liquid chromatography with fluorescence detection. Parameters affecting the performance of these steps are discussed. Validation results on linearity, selectivity, accuracy, precision, recovery and stability are shown, as well as the application of the method to samples from clinical trials.

Bexarotene↗

Membrane-based sample preparation coupled on-line to chromatography or electrophoresis.

A review on the use of membranes for on-line sample preparation prior to chromatographic and electrophoretic analysis is provided. The current state-of-the-art of four membrane-based techniques (dialysis, electrodialysis, filtration and membrane extraction) is described by reviewing their principles and applications. Possible future developments are discussed.

Chromatography↗

Determination of pilocarpine, isopilocarpine, pilocarpic acid and isopilocarpic acid in human plasma and urine by high-performance liquid chromatography with tandem mass spectrometric detection.

A method is described for the determination of pilocarpine and its degradation products isopilocarpine, pilocarpic acid and isopilocarpic acid in human plasma and urine. The method is based on a simple sample preparation step -- ultrafiltration for plasma and dilution for urine samples -- followed by a reversed-phase liquid chromatographic separation of the analytes and detection by means of tandem mass spectrometry. Parameters affecting the performance of these steps are discussed. The high sensitivity and selectivity of the method allow low ng/ml concentrations to be determined for all compounds in plasma and undiluted urine, which enables the investigation of the metabolic fate and elimination of pilocarpine after oral administration to humans.

Chromatography, High Pressure Liquid↗

Validated method for the determination of idazoxan in human plasma by liquid chromatography with tandem mass spectrometric detection.

A liquid chromatography-tandem mass spectrometry method for the determination of idazoxan in human (heparin) plasma is presented, which was developed and validated using 500 microl of sample. Sample preparation consisted of the addition of fluoroidazoxan as the internal standard, extraction at alkaline conditions into tert.-butyl methyl ether, followed by centrifugation, evaporation of the solvent and reconstitution in methanol. After a short chromatographic run, detection took place by ionspray tandem mass spectrometry in positive ion mode. Validation results on linearity, specificity, accuracy, precision and stability, as well as application of the method to samples from a clinical trial, are shown. The validated calibration range is from 0.300 to 100 ng/ml, with accuracy (bias) and precision (coefficient of variation) being below 15% at all levels. A sample throughput of, typically, 150 per day can be achieved.

Chromatography, Liquid↗

Automated on-line dialysis for sample preparation for gas chromatography: determination of benzodiazepines in human plasma.

An on-line dialysis-solid-phase extraction-gas chromatographic (GC) approach has been developed for the determination of drugs in plasma, using some benzodiazepines as model compounds. Clean-up is based on performing the dialysis of 100 microliters samples for 7 min using water as acceptor phase and trapping the diffused analytes on a PLRP-S copolymer precolumn. After drying of the precolumn with nitrogen for 15 min, the analytes are desorbed with ethyl acetate (275 microliters) and injected on-line into the GC system via a loop-type interface. The system provides a very efficient clean-up, and offers the possibility of adding chemical agents which can help to reduce drug-protein binding and, thus, increase sensitivity. To demonstrate the potential of the described approach, the determination of benzodiazepines in plasma at their therapeutical levels is used as an example with flame ionization, thermionic and mass-selective detection.

Anti-Anxiety Agents↗

Determination of the total concentration of highly protein-bound drugs in plasma by on-line dialysis and column liquid chromatography: application to non-steroidal anti-inflammatory drugs.

The potential of on-line dialysis as a sample preparation procedure for compounds highly bound to plasma proteins is evaluated, using non-steroidal anti-inflammatory drugs as model compounds and column liquid chromatography as the separation technique. Different strategies to reduce the degree of drug-protein binding and so increase the analyte recovery are systematically explored and discussed: alteration of the conformation of the binding protein by changing the pH of the sample or by adding an organic solvent, addition of several displacing compounds and combinations of such approaches. A fully automated method is presented for the determination of ketoprofen, ibuprofen, flurbiprofen, fenoprofen and naproxen in human plasma, in which the absolute analyte recoveries are increased from 0-1% (untreated samples) to 40-65%. Relevant analytical data are given to demonstrate the reliability of the proposed procedure.

Anti-Inflammatory Agents, Non-Steroidal↗

Automated column liquid chromatographic determination of amoxicillin and cefadroxil in bovine serum and muscle tissue using on-line dialysis for sample preparation.

A fully automated method is described for the determination of amoxicillin and cefadroxil in bovine serum and muscle tissue. The method is based on the on-line combination of dialysis and solid-phase extraction for sample preparation, and column liquid chromatography with ultraviolet detection. In order to enhance the UV detectability of the analytes, post-column addition of 0.1 M sodium hydroxide is performed. The method shows good linearity and repeatability for both analytes in serum as well as in muscle tissue; the limits of detection in these samples are 0.05 microgram/ml and 0.2 microgram/g, respectively. The method has a sample throughput of 30 samples per 24 h.

Amoxicillin↗

Determination of aflatoxin M1 using a dialysis-based immunoaffinity sample pretreatment system coupled on-line to liquid chromatography. Reusable immunoaffinity columns.

A liquid chromatographic column-switching system containing a dialysis unit and an anti-aflatoxin immunoaffinity precolumn (immuno precolumn) is described for the automated determination of aflatoxin M1 in milk samples. Both a flat membrane dialysis unit working according to the flowing donor-flowing acceptor principle and a laboratory made hollow-fibre dialysis unit working according to the stagnant donor-flowing acceptor principle were evaluated. The hollow-fibre unit is superior with respect to repeatability (3% relative standard deviation) and detection limit (10 ng/l for aflatoxin M1 in milk), in spite of the fact that the overall recovery is only 6%. Interfering compounds, which would destroy the activity of the immuno precolumn, are efficiently removed from the system by the dialysis step; a single immuno precolumn can then be used for over 70 milk analyses. No decrease in the performance of either the immuno precolumn or the hollow-fibre dialysis unit is observed.

Aflatoxin M1↗