PubMed Health⌕ Search

Biomedical subjects

N D Kon

Publications and source records attributed to N D Kon.

At least 19 recordsLinked to original sources

Benefit of glyceryl trinitrate on arterial stiffness is directly due to effects on peripheral arteries.

OBJECTIVE: To determine how the vasodilator glyceryl trinitrate (GTN) alters arterial stiffness and improves left ventricular afterload. METHODS: Ascending aortic pressure waves were measured with fluid filled catheters of high fidelity in 50 patients undergoing cardiac surgery, before cardiopulmonary bypass, both before and after intravenous infusion of GTN. In all 50 patients, wave reflection was identifiable as a secondary boost to late systolic pressure, permitting the pressure wave to be separated into a primary component, attributable to left ventricular ejection and properties of the proximal aorta, and a secondary component, attributable to reflection of the primary wave from the peripheral vasculature. RESULTS: GTN infusion caused no change in amplitude of the primary wave (mean (SD) 0.0 (1.4) mm Hg, not significant) but substantial reduction (14.6 (9.6) mm Hg, p < 0.0001) in amplitude of the secondary reflected wave. Fall in mean pressure was attributable to a mix of arteriolar and venous dilatation, with relative contributions unable to be separated. CONCLUSION: Favourable effects of GTN on arterial stiffness can be attributed to effects on peripheral muscular arteries, causing reduction in wave reflection. Results conform with previous invasive studies on vasodilator agents and their known effects on calibre and compliance of muscular arteries.

Adult↗

The second peak of the radial artery pressure wave represents aortic systolic pressure in hypertensive and elderly patients.

BACKGROUND: Simultaneous measurement of ascending aorta and radial artery pressure shows that mean and diastolic pressures (DP) are in close agreement in normotensive adults, while systolic pressures (SP) are not. However, in the aortic pressure wave, a second systolic peak appears with increasing age and increases to represent the SP by age 32 yr, while in the radial artery, a second systolic deflection appears by age 40 yr. We suggest that the second radial systolic wave, sometimes seen during radial arterial pressure monitoring in older hypertensives, represents the aortic SP. We set out to evaluate whether the aortic and radial second systolic peaks agree, and since doubts exist about the agreement between aortic and radial DP in elderly hypertensive patients, we also assessed that relationship. METHODS: We compared simultaneously recorded radial and aortic pressures from 21 anaesthetized adult patients using identical fluid-filled pressure measuring systems. CONCLUSIONS: The second radial pressure peak agreed with that in the aorta within a mean of 0.6 (SD 1.5) mm Hg. The difference between DP in the aorta and radial artery was -1.4 (2) mm Hg. The radial-aortic SP and pulse pressure differences were 5.9 (7.6) and 7.3 (7.6) mm Hg, respectively. These results confirm that when the radial artery pressure wave shows a first and second, or only a second systolic shoulder/peak (on the right side of the pressure wave), the second represents the maximal ascending aortic SP, and that the radial and aortic DP are equivalent, even in older hypertensive patients.

Adult↗

Steroid-free maintenance immunosuppression after heart transplantation.

BACKGROUND: Steroids are routinely used in almost all immunosuppressive protocols after cardiac transplantation. The metabolic side effects of steroids are well known and could lead to significant morbidity and mortality in the posttransplant period. There is growing evidence to suggest that steroids may not be a requirement for adequate immunosuppression and that morbidity may be reduced by withdrawing steroids in select patients. We have reviewed our series of patients undergoing heart transplantation in whom steroids were weaned postoperatively. METHODS: We retrospectively reviewed all adult patients undergoing heart transplantation at our institution between November 1993 and April 2000 treated with a-triple-drug immunosuppressive regimen. Medications were recorded at discharge and at 6, 12, and 24 months posttransplant to determine the success of steroid weaning. Freedom from infection and rejection as well as overall survival was calculated using Kaplan-Meier methods. RESULTS: By 24 months posttransplant, almost 70% of patients were receiving double-drug therapy. Survival for the entire group was excellent with 1-, 3-, and 5-year survival of 98%+/-2.0%, 93.2%+/-3.8%, and 88.3%+/-6.0%, respectively. Freedom from rejection at 6 months was 60.7%+/-6.5%, at 1 year was 60.7%+/-6.5%, and at 2 years was 58.5%+/-6.7%. Infectious complications were low with freedom from infection at 6 months of 78.5+/-5.5%, at 1 year of 76.5%+/-5.7%, and at 2 years of 72.0%+/-6.2%. CONCLUSIONS: Our data suggest that an immunosuppressive regimen without long-term steroid administration results in excellent survival rates without an apparent increase in rejection or infectious complications.

Adolescent↗

Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.

Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer function to synthesize the ascending aortic pressure pulse from the radial pulse. Validity of this approach was tested for estimation of aortic systolic, diastolic, pulse, and mean pressures from the radial pressure waveform. Ascending aortic and radial pressure waveforms were recorded simultaneously at cardiac surgery, before initiation of cardiopulmonary bypass, with matched, fluid-filled manometer systems in 62 patients under control conditions and during nitroglycerin infusion. Aortic pressure pulse waves, generated from the radial pulse, showed agreement with the measured aortic pulse waves with respect to systolic, diastolic, pulse, and mean pressures, with mean differences <1 mm Hg. Control differences in Bland-Altman plots for mean+/-SD in mm Hg were systolic, 0.0+/-4.4; diastolic, 0.6+/-1.7; pulse, -0.7+/-4.2; and mean pressure, -0.5+/-2.0. For nitroglycerin infusion, differences respectively were systolic, -0.2+/-4.3; diastolic, 0.6+/-1.7; pulse, -0.8+/-4.1; and mean pressure, -0.4+/-1.8. Differences were within specified limits of the Association for the Advancement of Medical Instrumentation SP10 criteria. In contrast, differences between recorded radial and aortic systolic and pulse pressures were well outside the criteria (respectively, 15.7+/-8.4 and 16.3+/-8.5 for control and 14.5+/-7.3 and 15.1+/-7.3 mm Hg for nitroglycerin). Use of a generalized transfer function to synthesize radial artery pressure waveforms can provide substantially equivalent values of aortic systolic, pulse, mean, and diastolic pressures.

Aged↗

Stentless aortic valve replacement with Freestyle or Toronto SPV: an early comparison.

BACKGROUND: Stentless aortic xenograft valves have been developed to overcome the disadvantages of conventional stented prostheses. We have implanted two new aortic bioprostheses: the Medtronic Freestyle and the St. Jude Toronto SPV. Early results are compared. METHODS: Forty-four Freestyle valves were implanted using a freestanding total root technique. Fourteen subcoronary Toronto SPV bioprostheses were implanted. Sixty-four percent of both groups (28 of 44 Freestyle and 9 of 14 Toronto SPV) underwent concurrent procedures. RESULTS: Ischemic time was 117 +/- 21 minutes for Freestyle and 124 +/- 19 minutes for Toronto SPV. There were no operative deaths or valve-related reoperations. Aortic valve area was 1.83 +/- 0.51 cm2 for Freestyle and 1.80 +/- 0.51 cm2 (p = 0.89) for Toronto SPV. Transvalvular gradient was 8.03 +/- 4.09 mm Hg for Freestyle and 12.4 +/- 1.82 mm Hg (p = 0.002) for the Toronto SPV. Aortic regurgitation was not experienced in any Freestyle patients, while Toronto SPV patients were graded as none to trace 79% (11 of 14), mild 14% (2 of 14), and moderate 7% (1 of 14). CONCLUSIONS: Aortic valve replacement with the Freestyle and Toronto SPV required equal time for implantation and had equal effective orifice areas. Freestyle had lower transvalvular gradient and less aortic insufficiency without increasing morbidity or mortality.

Aged↗

Prophylactic nitroglycerin did not reduce myocardial ischemia during accelerated recovery management of coronary artery bypass graft surgery patients.

OBJECTIVE: To evaluate the use of a high dose of nitroglycerin (NTG) for prophylaxis against myocardial ischemia and infarction in patients undergoing coronary artery bypass graft (CABG) surgery with accelerated recovery. DESIGN: Prospective, double-blind, placebo-controlled randomized study. SETTING: A university-based medical center. PARTICIPANTS: Forty adult patients presenting for elective CABG surgery. INTERVENTIONS: Forty patients were divided into 2 blinded study groups. Twenty patients received 2 microg/kg/min of NTG starting before induction of anesthesia and continuing for 6 hours after extubation in the intensive care unit. The placebo group (n = 20) received normal saline during this same interval. MEASUREMENTS AND MAIN RESULTS: Hemodynamics, incidence and severity of myocardial ischemia, and myocardial infarction rates were determined. There were no differences in hemodynamic parameters between groups. The incidence of ischemia was approximately 35% in each group. Myocardial infarction (as determined by elevated creatine kinase-MB fraction, troponin I, and electrocardiogram criteria) was 10% in the placebo group and 5% in the NTG group (p = 0.234). CONCLUSIONS: This study shows a high incidence of myocardial ischemia and infarction in patients presenting for CABG surgery with an accelerated recovery management scheme. NTG was well tolerated clinically; however, it was not found to be protective against myocardial ischemia or infarction in this setting.

Adult↗

Aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis.

BACKGROUND: Stentless porcine prosthetic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation and perhaps improved durability. METHODS: One hundred and twelve patients were operated on from September 17, 1992 to April 13, 1998 as part of a multi-center worldwide investigation. All patients received a total aortic root replacement. Patients were evaluated postoperatively at discharge, 3 to 6 months, and yearly by clinical exam and color flow Doppler echocardiography. RESULTS: There were 4 deaths either in the hospital or within 30 days after surgery for an operative mortality of 3.6%. No patients experienced structural valve deterioration, non-structural valve deterioration, paravalvular leak, unacceptable hemodynamic performance, or postoperative endocarditis. The linearized rates for survival and thromboembolic complications at 5 years were 82.8% and 90.5% respectively. Excellent hemodynamic function is demonstrated by very low gradients, large EOA, and an exceedingly low incidence of any aortic regurgitation. CONCLUSIONS: The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root for aortic valve and aortic root pathology. Root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Early and intermediate results are encouraging, but further follow-up is needed to determine valve durability.

Adult↗

Aortic valve replacement with Medtronic Freestyle bioprosthesis: 5-year results.

The Medtronic Freestyle aortic root bioprosthesis has been implanted in patients since August 1992. This study reviews clinical and echocardiographic results at midterm (5 years) after implantation. The Freestyle bioprosthesis was implanted in 1,100 patients in a 21-center Food and Drug Administration clinical trial from August 1992 to October 1998. The device was implanted (1) as a subcoronary valve replacement, (2) as a complete aortic root replacement (full-root), or (3) as a root inclusion. Patients were followed annually by clinical examination and echocardiography. There were 47 deaths early after operation (7.1%). There were 2,478 patient-years of follow-up during which there were 99 deaths or 4.0/pt.-yr. Before implantation, 73% of patients were in New York Heart Association functional class III or IV. After operation, 95% were in class I or II. Transvalvular gradient 4 years after operation was low (7.5+/-5.3 mm Hg) for all valve sizes (subcoronary implant). Small valves (19 and 21 mm) had mean gradients (10.2+/-3.0, 9.1+/-4.4 mm Hg). There was no or mild valve insufficiency in 98% of patients. Actuarial analysis at 5 years showed the rate for freedom from thromboembolism of 86% in subcoronary implant and 93% in full root replacement. Freedom from endocarditis was 98%. Freedom from reoperation for explant of the valve highest in patients having full root replacement (98%) and lower with root inclusion (94%). There were 20 bioprostheses explanted; 10 for endocarditis, 8 for technical reasons, and 2 for structural deterioration. The Medtronic Freestyle bioprosthesis (1) has excellent hemodynamic performance, (2) techniques for insertion that result in a competent valve, (3) low rates of thromboembolism and endocarditis, and (4) a rare rate of structural deterioration at 5 years.

Aged↗

Comparison of results using "freestyle" stentless porcine aortic root bioprosthesis with cryopreserved aortic allograft.

Aortic valve replacement with natural heart valves offer the advantages of superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability. This study compares 5-year results for two stentless aortic valves. In 1992, two prospective clinical trials using two different stentless aortic valves were initiated at our center. The Freestyle stentless porcine aortic root bioprosthesis (SPB) was placed in 106 patients, and cryopreserved aortic allografts (CAA) were placed in 174 patients using a freestanding total root replacement technique in each series. The mean systolic gradient for the SPB was 7.5+/-4.4 mm Hg at discharge and 5.9+/-3.1 mm Hg at 5 years. The mean systolic gradient for the CAA was 6.4+/-3.3 mm Hg at discharge and 5.0+/-2.2 mm Hg at 5 years. At discharge 92.2% of SPB patients had no aortic insufficiency (AI) and 7.8% had trivial AI. In all, 92.9% of CAA patients had no AI at discharge, and 7.1% had mild AI. At 5-year follow-up, 100% of the SPB had no AI, and only 20% of the allograft patients had no AI. The remainder, 80%, had mild AI. Excellent hemodynamic function was seen with both SPB and CAA. A lower incidence of nonhemodynamically significant AI was observed in the SPB group. Preoperative factors such as chronic renal failure and endocarditis may have adversely affected durability in the allograft group, but long-term follow-up is still required to determine durability.

Adult↗

Mitral valve replacement in sickle cell disease.

Cardiac dysfunction, including mitral valve regurgitation and congestive heart failure, can occur in patients with sickle cell disease. However, major surgery poses a greater risk in this population. This paper reports on the management of a patient with sickle cell disease who underwent successful replacement of the mitral valve.

Adult↗

Three-dimensional surface area of the aortic valve orifice by three-dimensional echocardiography: clinical validation of a novel index for assessment of aortic stenosis.

BACKGROUND: A direct and accurate method of assessing aortic valve area (AVA) in patients with aortic stenosis (AS) is desirable because of the well-known theoretical and practical limitations of the currently available methods. We assessed the clinical feasibility and accuracy of a novel index, the 3-dimensional surface area (3-DSA) of the aortic valve orifice by 3-dimensional transesophageal echocardiography (3-DTEE) in patients with AS. METHODS: Intraoperative 3-DTEE was performed in 23 consecutive patients (mean age 58 +/- 15 years) with valvular AS using a Toshiba SSA-380A system with a multiplane TEE probe and a TomTec EchoScan system. The 3-DTEE acquisition, processing and reconstruction were conducted and the aortic valve orifice presented using a "surgeon's aortotomy view" (aortic valve orifice as if viewed through an open aortic root). The 3-D images were videotaped and calibrated and the 3-DSA measured by planimetry of the inner surface of the aortic valve leaflets at the maximal systolic opening using the dynamic 3-D images. For comparison, the 2-D cross sectional area (2-DCSA) of the aortic valve was also determined by 2-DTEE. The 3-DSA and 2-DCSA were compared with the AVA by the invasive Gorlin formula and the Doppler continuity equation method by transthoracic echocardiography. RESULTS: The 3-DSA and 2-DCSA measurements were feasible in all but one patient. Both 3-DSA and 2-DCSA correlated moderately well with the AVA by the Gorlin formula (n = 17, r = 0.66, standard error of the estimate [SEE] = 0.3 cm2, P <.05 for 3-DSA and r = 0.61, SEE = 0. 5 cm2 P <.05 for 2-DCSA, respectively). They also correlated well with the AVA by Doppler continuity equation method (n = 22, r = 0.90, SEE = 0.1 cm2, P <.05 for 3-DSA and r = 0.83, SEE = 0.3 cm2, P <.05 for 2-DCSA, respectively). There was no statistically significant difference between the 3-DSA and AVA by both the Gorlin formula (Delta = 0.1 +/- 0.3 cm2, P =.3) and the Doppler continuity equation (Delta = -0.0 +/- 0.3 cm2, P =.7). In contrast, the 2-DCSA significantly overestimated AVA by the Gorlin formula (Delta = 0.5 +/- 0.5 cm2, P <.005) and by the Doppler continuity equation (Delta = 0.5 +/- 0.6 cm2, P <.0001). CONCLUSIONS: Planimetry of 3-DSA of the aortic valve orifice by 3-DTEE is a clinically feasible and relatively accurate technique for assessment of AVA and is superior to 2-DCSA by 2-DTEE.

Adult↗

Dobutamine antagonizes epinephrine's biochemical and cardiotonic effects: results of an in vitro model using human lymphocytes and a clinical study in patients recovering from cardiac surgery.

BACKGROUND: Patients may receive more than one positive inotropic drug to improve myocardial function and cardiac output, with the assumption that the effects of two drugs are additive. The authors hypothesized that combinations of dobutamine and epinephrine would produce additive biochemical and hemodynamic effects. METHODS: The study was performed in two parts. Phase 1 used human lymphocytes in an in vitro model of cyclic adenosine monophosphate (cAMP) generation in response to dobutamine (10(-8) to 10(-4) M) or epinephrine (10(-9) M to 10(-5) M), and dobutamine and epinephrine together. Phase 2 was a clinical study in patients after aortocoronary artery bypass in which isobolographic analysis compared the cardiotonic effects of dobutamine (1.25, 2.5, or 5 microg x kg(-1) x min(-1)) or epinephrine (10, 20, or 40 ng x kg(-l) x min(-1)), alone or in combination. RESULTS: In phase 1, dobutamine increased cAMP production 41%, whereas epinephrine increased cAMP concentration approximately 200%. However, when epinephrine (10(-6) M) and dobutamine were combined, dobutamine reduced cAMP production at concentrations between 10(-6) to 10(-4) M (P = 0.001). In patients, 1.25 to 5 microg x kg(-1) x min(-1) dobutamine increased the cardiac index (CI) 15-28%. Epinephrine also increased the CI with each increase in dose. However, combining epinephrine with the two larger doses of dobutamine (2.5 and 5microg x kg(-1) x mi(-1)) did not increase the CI beyond that achieved with epinephrine and the lowest dose of dobutamine (1.25 microg x kg(-1) x min(-1)). In addition, the isobolographic analysis for equieffective concentrations of dobutamine and epinephrine suggests subadditive effects. CONCLUSIONS: Dobutamine inhibits epinephrine-induced production of cAMP in human lymphocytes and appears to be subadditive by clinical and isobolographic analyses of the cardiotonic effects. These findings suggest that combinations of dobutamine and epinephrine may be less than additive.

Adrenergic Agonists↗

Feasibility, accuracy, and incremental value of intraoperative three-dimensional transesophageal echocardiography in valve surgery.

In this prospective trial, intraoperative 2-dimensional (2-D) and 3-dimensional (3-D) transesophageal echocardiography (TEE) examinations were performed on 60 consecutive patients undergoing cardiac valve surgery. Both 2-D (including color flow and Doppler data) and 3-D images were reviewed by blinded observers, and major valvular morphologic findings recorded. In vivo morphologic findings were noted by the surgeon and all explanted valves underwent detailed pathologic examination. To test reproducibility, 6 patients also underwent 3-D TEE 1 day before surgery. A total of 132 of 145 attempted acquisitions (91%) were completed with a mean acquisition time of 2.8 +/- 0.2 minutes. Acquisition time was significantly shorter in patients with regular rhythms. Reconstructions were completed in 121 of 132 scans (92%) and there was at least 1 good reconstruction in 56 of 60 patients (93%). Mean reconstruction time was 8.6 +/- 0.7 minutes. Mean effective 3-D time, which was the time taken to complete an acquisition and a clinically interpretable reconstruction, was 12.2 +/- 0.8 minutes. Intraoperative 3-D echocardiography was clinically feasible in 52 patients (87%). Three-D echocardiography detected most of the major valvular morphologic abnormalities, particularly leaflet perforations, fenestrations, and masses, confirmed on pathologic examination. Three-D echocardiography predicted all salient pathologic findings in 47 patients (84%) with good quality images. In addition, in 15 patients (25%), 3-D echocardiography provided new additional information not provided by 2-D echocardiography, and in 1 case, 3-D echocardiographic findings resulted in a surgeon's decision to perform valve repair rather than replacement. In several instances, 3-D echocardiography provided complementary morphologic information that explained the mechanism of abnormalities seen on 2-D and color flow imaging. In the reproducibility subset, preoperative and intraoperative 3-D imaging detected a similar number of findings when compared with pathology. Thus, in routine clinical intraoperative settings, 3-dimensional TEE is feasible, accurately predicts valve morphology, and provides additional and complementary valvular morphologic information compared with conventional 2-D TEE, and is probably reproducible.

Adolescent↗

Risk factors and solutions for the development of neurobehavioral changes after coronary artery bypass grafting.

BACKGROUND: As operative mortality for coronary artery bypass grafting has decreased, greater attention has focused on neurobehavioral complications of coronary artery bypass grafting and cardiopulmonary bypass. METHODS: To assess risk factors and to evaluate changes in surgical technique, between 1991 and 1994 we evaluated 395 patients undergoing coronary artery bypass grafting with an 11-part neurobehavioral battery administered preoperatively and at 1 and 6 weeks postoperatively. Patients were instrumented with 5-MHz focused continuous-wave carotid Doppler transducers intraoperatively to estimate cerebral microembolism as an instantaneous perturbation of the velocity signal. Microembolism data were quantitated and compared with surgical technical maneuvers during operation and with neurobehavioral deficit (> or = 20% decline from preoperative performance on two or more neurobehavioral tests) postoperatively. These data and patient demographics were statistically analyzed (chi2, t test) and the results at 2 years (1991 and 1992; group A) were used to influence surgical technique in 1993 and 1994 (group B). RESULTS: Significantly associated with new neurobehavioral deficits were increasing patient age (p < 0.05), more than 100 emboli per case (p < 0.04), and palpable aortic plaque (p < 0.02). Group B patients had a significant decline in the neurobehavioral event rate (group A, 69%, 140/203; versus group B, 60%, 115/192; p < 0.05) of postoperative neurobehavioral deficits at 1 week and at 1 month (group A, 29%, 52/180; versus group B, 18%, 35/198; p < 0.01). The stroke rate was less than 2% in both groups (p = not significant). Modifications of surgical technique used in group B patients included increased use of single cross-clamp technique, increased venting of the left ventricle, and application of transesophageal and epiaortic ultrasound scanning to locate and avoid trauma to aortic atherosclerotic plaques. CONCLUSIONS: Neurobehavioral changes after coronary artery bypass grafting are common and associated with cerebral microembolization. Surgical technical maneuvers designed to reduce emboli production may improve neurobehavioral outcome.

Aged↗

Accuracy of transesophageal echocardiography in preoperative determination of aortic anulus size during valve replacement.

This prospective, blinded study evaluated the accuracy of transesophageal (TEE) and transthoracic echocardiography in predicting the size of the surgical aortic valve anulus in 20 consecutive patients undergoing aortic valve replacement. TEE was highly accurate in predicting surgical aortic valve anulus size (r = 0.98; p < 0.00001). The standard error of the TEE estimate of the size of the obturator anulus was only 0.04 mm, and in all cases the TEE estimate was within 1 mm of the direct surgical measurement. Both biplane and multiplane TEE probes were equally accurate and this accuracy was maintained over a wide range of sizes of surgical aortic anulus. Transthoracic echocardiography appeared less accurate in predicting anulus size (r = 0.64; p < 0.08). Therefore TEE can be used routinely for selection and preparation of aortic allografts before sternotomy, potentially reducing cardiopulmonary bypass pump time by 10 to 30 minutes and ensuring optimal size matching of the donor-recipient anulus.

Adolescent↗

Morphology and dynamic change of discrete subaortic stenosis can be imaged and quantified with three-dimensional transesophageal echocardiography.

This report describes three-dimensional transesophageal echocardiographic findings in three consecutive patients with discrete subaortic stenosis. The discrete subaortic stenosis lesions included a circumferential, a remnant crescent, and a broken fibrotic subaortic membrane. The lesions were best imaged by using a three-dimensional transesophageal echocardiography-generated "aortotomy view" of the left ventricular outflow tract immediately below the plane of the aortic valve. The three-dimensional images correlated well with surgical and pathologic findings. The three-dimensional surface areas of the left ventricular outflow tract at the level of discrete subaortic stenosis during systole (0.8 +/- 0.5 cm2) and diastole (1.7 +/- 0.7 cm2) were measured by planimetry of the three-dimensional transesophageal echocardiographic images. The novel "aortotomy view" offered by three-dimensional transesophageal echocardiography provided direct visualization and quantification of discrete subaortic stenosis in a dynamic fashion. In summary, three-dimensional transesophageal echocardiography can accurately display and quantify discrete subaortic stenosis and could be a new clinically useful tool for assessing discrete subaortic stenosis and guiding surgical and transcatheter interventions.

Adult↗

Acute right ventricular failure during aortic valvular operation due to mechanical problem in the right coronary artery.

BACKGROUND: When right ventricular failure occurs during aortic valvular operation, inadequate myocardial protection may be the culprit. However, other causes of right ventricular failure should be considered, such as air or particulate matter embolization. Right ventricular failure unexpectedly occurred during an aortic valvular operation, and the cause was found to be a mechanical problem with the right coronary ostium. METHODS: A mechanical problem with the right coronary artery (RCA) occurred in 9 patients undergoing aortic valvular procedures, which included isolated aortic valve replacement (4 patients), aortic valve replacement and coronary artery bypass (1 patient), Bentall procedure (2 patients), aortic valve reconstruction (1 patient), and double valve replacement and coronary artery bypass (1 patient). Although myocardial protection was considered to be the cause, a mechanical problem was subsequently identified in the RCA, leading that artery to be bypassed with a segment of saphenous vein. RESULTS: The 1 patient in whom the condition was not recognized at time of aortic valve operation died; at autopsy, a damaged and occluded right ostium was confirmed. The other 8 patients who had the RCA bypassed survived. CONCLUSIONS: We conclude that when right ventricular failure unexpectedly occurs during an aortic valvular operation and does not improve with reperfusion, a mechanical problem in the RCA should be considered. In this situation we recommend that the RCA be bypassed with a segment of saphenous vein graft.

Acute Disease↗