Cementing techniques in hip resurfacing.

The subject of the cementing technique in hip resurfacing has been poorly studied to date. The hip resurfacing prosthesis is unique in the family of cemented prostheses because the cement mantle is blind (hidden underneath the implant) and is radiographically obscured. This presents an immediate challenge to the surgeon at the time of surgery, but also has a longer-term implication in terms of lack of post-operative clinical observation. This should be compared with total hip replacement or total knee replacement where the cement mantle can at least be partially observed both intra- and post-operatively. With this in mind, the objective of this review is, firstly, to understand the cement mantles typically achieved in current clinical practice and, secondly, to identify those factors affecting the cement mantle and to consolidate them into an improved and reproducible cementing technique. The outcome of this work shows that the low-viscosity technique can commonly lead to excessive cement penetration in the proximal femoral head and an incompletely seated component, whereas a more consistent controlled cement mantle can be achieved with a high-viscosity cementing technique. Consequently, it is recommended that a high-viscosity technique should be used to minimize the build-up of excessive cement, to reduce the temperature created by the exothermic polymerization, and to help to ensure correct seating of the prosthesis. A combination of these factors is potentially critical to the clinical success of some articular surface replacement (ASR) procedures. It is important to note that we specifically studied the DePuy ASR system; therefore only the general principles (and not the specifics) of the cementing technique may apply to other resurfacing prostheses, because of differences in internal geometry, clearance, and surgical technique.

Adhesiveness↗

Dynamic creep and mechanical characteristics of SmartSet GHV bone cement.

The restrained dynamic creep behaviour and mechanical properties of SmartSet GHV bone cement have been investigated at both room temperature and body temperature. It was found that the bone cement behaves significant differently at room temperature from that at body temperature. The test temperature had a strong effect on the creep performance of the bone cements with a higher creep rate observed at body temperature at each loading cycle. For both temperatures, two stages of creep were identified with a higher creep rate during early cycling followed by a steady state creep rate. The relationship between creep deformation and loading cycle can be expressed by a Hyperb 1 model. As a visco-elastic material, the sensitivity of bone cement to the temperature change was evident during mechanical testing. Compared to the mechanical strength at room temperature, a decreased value was demonstrated at body temperature. The bending modulus was very sensitive to the change in testing temperature, where a reduction of 52% was recorded. A significant reduction in compressive and bending strength, 31 and 23% were recorded respectively. The effect of temperature on bending strength was less apparent, where only 13% reduction was exhibited at body temperature compared to room temperature.

Bone Cements↗

A preliminary hip joint simulator study of the migration of a cemented femoral stem.

A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemented femoral stem within a novel composite femur. The study demonstrates the value of using a hip joint simulator to evaluate the outcome of the cemented hip construct. A complex migration pattern of the cemented hip prosthesis with respect to load cycling was observed, demonstrated in vitro comparable prosthesis migration behaviour, both the stem migration and migration patterns, to that found clinically.

Cementation↗

Creep behavior comparison of CMW1 and palacos R-40 clinical bone cements.

The restrained dynamic creep behaviors of two clinical bone cements, Palacos R-40 and CMW1 have been investigated at room temperature and body temperature. It was found that the two cements demonstrated significantly different creep deformations, with Palacos R-40 bone cement demonstrating higher creep strain than CMW1 bone cement at each loading cycle. For both cements, two stages of creep were identified with a higher creep rate during early cycling followed by a steady-state creep rate. The test temperature had a strong effect on the creep performance of the bone cements with higher creep rate observed at body temperature. The relationship between creep deformation and loading cycles can be expressed by single logarithmic model. The SEM examinations revealed that CMW1 bone cement is more sensitive to defects within the specimen especially to the defects at the edges of the specimen than Palacos R-40 bone cement. However, in the absence of micro-cracks or defects within the inner surface layer, the dynamic loading (at less than 10.6 MPa) is unlikely to produce micro-cracks in the CMW1 bone cement. The different behaviors between the two bone cements may be attributed to differences in chemical compositions and molecular weight distributions.

Journal Article↗

Some failure modes of four clinical bone cements.

The fracture or failure behaviours of four commercial acrylic-based bone cements have been examined in tensile, bending and compression modes, and their mechanical properties are reviewed. It was found that Palacos R-40 bone cement had high radiopaque agent concentration, with high surface hardness. It exhibited a much lower bending strength and bending modulus compared with the other three bone cements (CMW1, CMW2000 and Simplex P). The textures of tensile fracture surfaces produced were similar for the four bone cements studied. The fracture surface was fragmented by crevices, which developed through the matrix and around large undissolved polymethylmethacrylate (PMMA) beads. Three bands with different features existed on the bending fracture surfaces, with an abrupt transition between them. It appears that the agglomerates of zirconium dioxide particles are implicated in Palacos R-40 bone cement fracture surface. The examination of compressive failed specimens revealed that a 'yielded crack band' existed across the transverse section. Plastic deformation resulted in the PMMA beads being squashed in the longitudinal direction and dilated in the transverse direction.

Biomechanical Phenomena↗

Geomagnetic polarity change, volcanic maxima and faunal extinction in the South Pacific.

Studies of deep-sea sedimentary cores from Antarctic Pacific waters show that some volcanic maxima occurred when the geomagnetic polarity was changing. Upper mantle activity and geomagnetic polarity change may therefore be related. Coincidences of faunal extinction and geomagnetic polarity change may be explained by corresponding volcanically induced climatic changes.