Recurrent noisy pneumothorax mimicking pericarditis.

Sounds related to the cardiac cycle may have an extra-cardiac origin. We report a case of recurrent noisy pneumothorax producing a loud rub, audible at a distance from the patient and initially diagnosed as pericarditis. The sounds and their mechanisms of production in this condition are also discussed.

Adolescent↗

How often should defibrillation pads be changed?: the effect of evaporative drying.

OBJECTIVE: In order to minimise transthoracic impedance (TTI) during defibrillation, water-based pads are used to improve conductivity between metal defibrillation paddles and skin. Subjectively, these pads appear to dry very quickly; an effect that may lead to an increase in TTI due to poorer conduction between paddles and skin. This study was carried out to assess the effect of evaporative drying of defibrillation pads on TTI. MATERIALS AND METHODS: TTI was measured at 5-10 min intervals in 20 adult male volunteers across 3M defibrillation pads (2346N) placed in the anterior-apical position. Measurements of TTI were made at 30 kHz using a Bodystat MultiScan 5000 monitor at end-expiration. A third pad was placed on the left precordium and its mass recorded each time a TTI measurement was made. RESULTS: The median age of subjects was 22 years (range 21-52 years) and their median body mass index was 23.1 kg m(-2) (range 18.4-42.8 kg m(-2)). Median room temperature was 23.0 degrees C (range 19.0-24.0 degrees C) and the median humidity was 31.0% (range 28.0-48.0%). 3M defibrillation pads had an initial mean mass of 25.14 g (S.D. +/- 0.41 g). Changes in defibrillation pad mass due to evaporative loss occurred immediately and rapidly, with all measurements being significantly lower than the baseline value. Mean baseline TTI was 63.6 ohms (S.D. +/- 13.7 ohms). After 30 min a statistically significant (P = 0.012) rise of 1.4 ohms (2.2%), was observed corresponding to a 12.6% decrease in pad mass, after which TTI continued to increase in a linear fashion. CONCLUSION: In the absence of a defibrillation current. 3M defibrillation pads can safely be left on the chest wall for at least 25 min in a typical hospital environment before evaporative drying results in a significant increase in transthoracic impedance.

Adult↗

Evidence-based guidelines for the use of defibrillation pads.

OBJECTIVE: Defibrillation pads are used routinely at both cardiac arrests and cardioversion procedures. There are currently no evidence-based guidelines on how often pads should be replaced, although it has been suggested that they should be changed as often as every three shocks to maintain optimal performance. Previously, we have shown that on exposure to air, pad mass diminishes over time due to evaporation--an effect likely to lead to poorer conduction between skin and paddle. This prospective study was designed to determine if evaporation is accelerated by the passage of a defibrillation current and to formulate evidence-based guidelines for defibrillation pad replacement. MATERIALS AND METHODS: 3M defibrillation pads (2346N) were collected from acute wards and emergency departments in two hospitals in the UK over a 2 month period. The duration of exposure to air, number and energy of shocks, and type of procedure were recorded. When no longer required, pad masses were determined and the loss of pad mass due to evaporation calculated. RESULTS: 26 pairs of pads were collected from 14 cardiac arrests and 12 cardioversions. The total defibrillation energy used ranged from 150 to 5080 J and evaporative drying time from 4 to 38 min. The rate of evaporation from these pads (86.1 mg x min(-1)) was not significantly different from pads previously studied on volunteers in the absence of a defibrillation current (99.4 mg x min(-1)). Of the defibrillation pads exposed to air for less than 30 min, in only one of 49 pads was the loss of mass due to evaporation consistent with a significant increase in transthoracic impedance (TTI). Correspondingly, of two pads used for more than 30 min, both attained a mass consistent with a significant increase in TTI. CONCLUSIONS: Defibrillation pads can be used for up to 30 min without evaporation causing a clinically significant increase in TTI. The passage of a defibrillation current across pads does not further accelerate water loss.

Electric Countershock↗