PubMed Health⌕ Search

Biomedical subjects

N Eigler

Publications and source records attributed to N Eigler.

At least 37 records · Page 2Linked to original sources

Percutaneous excimer laser coronary angioplasty: results in the first consecutive 3,000 patients. The ELCA Investigators.

OBJECTIVES: We report the comprehensive results of the first consecutive 3,000 patients treated in an excimer laser coronary angioplasty registry. BACKGROUND: Excimer laser coronary angioplasty involves the use of a pulsed, 308-nm ultraviolet laser transmitted by optical fibers to reduce coronary stenoses. Preliminary reports have described safety and efficacy profiles in small numbers of patients. METHODS: Patients were enrolled in a prospective, nonrandomized manner. The catheters used were 1.3, 1.6, 2.0, 2.2 and 2.4 mm in diameter, at energy densities up to 70 mJ/mm2. Procedures were performed by standard angioplasty technique with conventional guide catheters. RESULTS: Seventy-five percent of patients were male, 68% were in Canadian Cardiovascular Society functional class III or IV and the cohort included 3,592 lesions. Procedural success (final stenosis < or = 50% without in-hospital Q wave myocardial infarction, coronary artery bypass surgery or death) was 90% and did not differ between the first 2,000 and the last 1,000 patients treated. There was no significant difference in success or complication rates with respect to lesion length, nor were there differences between selected complex and simple lesions. Complications included in-hospital bypass surgery (3.8%), Q wave myocardial infarction (2.1%) and death (0.5%). Coronary artery perforation occurred in 1.2% of patients (1% of lesions) but significantly decreased to 0.4% in the last 1,000 patients (0.3% of lesions). Angiographic dissection occurred in 13% of lesions, transient occlusion in 3.4% and sustained occlusion in 3.1%. Comprehensive lesion morphologic data collected in the latter portion of the study showed the procedure predominantly limited to American College of Cardiology-American Heart Association type B2 and C lesions, with no significant difference in short-term outcome between groups. CONCLUSIONS: Excimer laser angioplasty can be safely and effectively applied, even in a variety of complex lesions not well suited for percutaneous transluminal coronary angioplasty. These types may include aorto-ostial, long lesions, total occlusions crossable with a wire, diffuse disease and vein grafts. Most recent data show a trend for the selection of predominantly complex lesions and a reduction in the incidence of perforation. This procedure may broaden the therapeutic window for the interventional treatment of selected complex coronary artery disease.

Angioplasty, Balloon, Coronary↗

Current status and prospects for the use of temporary stents.

Temporary stenting appears to be an attractive potential therapy that combines some of the benefits of permanent stenting without the need for permanent endovascular prostheses and oral anticoagulation. The devices used for temporary stenting are still evolving. The Flow Support Catheter showed promise in the early clinical trial phase but is not being pursued by the original manufacturer because the device was associated with a high rate of thrombosis and suboptimal overall success rate. The experience with the Instent is limited and the removal of its unattached version relies upon catching the end of the stent in the retrieval device (a wire loop); also, its safety and reliability still need to be proved. The HARTS device is currently in the preclinical phase, but available data from animal studies show it to be a feasible device for coronary use. Its potential applications include use as a permanent stent, a temporary stent, a repositionable stent, a primary lesion-dilating device, or a local drug-delivery vehicle. Clinical trials are likely to commence in the foreseeable future for one or more of these applications.

Administration, Oral↗

Quantitative severity of stress thallium-201 myocardial perfusion single-photon emission computed tomography defects in one-vessel coronary artery disease.

The relation between the quantitative myocardial perfusion defect severity of exercise thallium-201 single-photon emission computed tomography (SPECT) and the quantitative degree of coronary stenosis was examined in 18 patients with 1-vessel disease (> or = 50% diameter stenosis), and abnormal thallium-201 SPECT. A total of 26 vessels were analyzed. Thallium-201 SPECT quantitative defect severity score was derived by summing the number of pixels in a coronary territory in which counts fell below the normal mean and multiplied by the number of SDs by which they fell below the normal mean. The thallium-201 defect severity score was significantly (p < 0.001) related to the maximal percent luminal diameter narrowing (r = 0.93), percent area narrowing (r = 0.89), absolute stenotic area (r = 0.79), and absolute stenotic diameter (r = 0.81). As expected, the strongest relation between thallium-201 defect severity and quantitative angiographic indexes was in the low and high ranges of coronary stenosis, with more variability and lower correlation coefficients (percent diameter: r = 0.75, p < 0.02, percent area stenosis: r = 0.63, p < 0.05) in the middle ranges (50 to 80% diameter stenosis). This observation is likely to be due to the complex flow characteristics across stenotic lesions. The findings suggest that in a select population, thallium-201 defect severity is potentially useful for noninvasive characterization of the functional severity of coronary artery stenosis and may complement coronary angiography in predicting functionally significant stenosis.

Adult↗

Treatment of refractory coronary occlusions with a new excimer laser catheter: preliminary clinical observations.

BACKGROUND: Total coronary occlusion is a frequent cause of procedural failure after coronary angioplasty, often because of the inability to recanalize the occluded segment with a conventional coronary guidewire. The novel excimer laser catheter described in this report contains a highly efficient, pulsed excimer laser guidewire designed to create a small channel within the occluded coronary segment. A preliminary report of the safety and efficacy of this excimer laser catheter is provided. METHODS: Ten patients with refractory coronary occlusions that could not be crossed by experienced operators using conventional guidewire techniques were treated using a novel laser catheter system. The laser catheter consisted of a densely packed, multiple fiber, helical guidewire measuring 0.020 inches (0.51 mm) in diameter, interfacing a 308 nm excimer laser system and delivering 70-80 mJ/mm2 of energy to the output surface. After the laser guidewire had been advanced to the occlusion site, laser energy was applied to ablate a channel as the wire was advanced through the occlusion. Once the occlusion had been recanalized, standard concentric laser or balloon angioplasty was performed. RESULTS: Complete recanalization was achieved in three total occlusions, and partial recanalization was established in a further three; thus, normal coronary perfusion was attained in six out of 10 patients after adjunct excimer laser or balloon angioplasty. The final minimum lumen diameter averaged 1.51 mm and the final residual stenosis diameter was 27%. In two patients the procedure was unsuccessful but without significant complications; two other patients developed limited coronary perforations without clinical sequelae. CONCLUSION: Refractory coronary occlusions were successfully recanalized in six out of 10 patients using a novel excimer laser catheter. Treatment failures in four patients were not associated with major complications, although limited coronary perforation occurred in two patients.

Angioplasty, Balloon, Coronary↗

Morphological predictors of acute complications after percutaneous excimer laser coronary angioplasty. Results of a comprehensive angiographic analysis: importance of the eccentricity index.

BACKGROUND: Percutaneous excimer laser coronary angioplasty (ELCA) is a new technique for recanalization of arteries obstructed by coronary atherosclerosis. This study was conducted to assess the complication rate and determine the influence of clinical and angiographic characteristics on complications after ELCA. METHODS AND RESULTS: A detailed, quantitative, angiographic core laboratory analysis of patients undergoing ELCA was performed by two experienced angiographers who were not the primary laser angioplasty operators. Two hundred patients underwent 203 separate procedures on 220 lesions at three medical centers. Laser success was achieved in 180 lesions (81.8%) and procedural success in 199 (90.5%). Emergency coronary artery bypass graft (CABG) was required in five patients (2.5%). One patient suffered a Q wave myocardial infarction; there were no deaths. Also, acute closure and perforation occurred in 10 (4.5%) and three (1.4%) vessels, respectively. Coronary dissections after laser treatment were seen in 36 vessels (16.4%). Multivariate analysis found two independent preprocedural factors related to complications: eccentricity index, which is the percent deviation of the lesion lumen from the center of the artery (p = 0.0007), and proximal vessel diameter (p = 0.033). In addition, an abrupt proximal face of the lesion was associated with angiographic complications by univariate analysis (p = 0.051). Multivariate analysis showed the eccentricity index (p = 0.032) to be the only independent predictor for the occurrence of any one or more of the important complications (emergency CABG, perforation, acute closure, or Q wave myocardial infarction), whereas lesion angle greater than 45 degrees was a significant univariate predictor (p = 0.029). Other predictors of complications with balloon percutaneous transluminal coronary angioplasty, such as increased lesion length, rough edges, calcification, ulceration, and branch point, were not predictive of complications with the excimer laser. CONCLUSIONS: The degree of lesion eccentricity is the most powerful predictor of complications after ELCA. This and other morphological predictors may be of benefit in the selection of patients for ELCA as well as directing future development of this new technology.

Aged↗

Internal mammary artery to lung parenchyma fistula after aortocoronary bypass grafting.

Two unusual cases of internal mammary artery fistulization to lung parenchyma after coronary revascularization are reported. They were incidentally discovered during coronary angiography, and one of them was successfully closed with a percutaneous transvenous coil-spring occluder. The cause is thought to be the direct contact between the dissected mammary artery pedicle and the lung parenchyma.

Coronary Artery Bypass↗

Synchronized coronary venous retroperfusion for support and salvage of ischemic myocardium during elective and failed angioplasty.

To determine the safety and efficacy of synchronized coronary venous retroperfusion during brief periods of ischemia, 30 patients undergoing angioplasty of the left anterior descending coronary artery were studied. Each patient underwent a minimum of two angioplasty balloon inflations. Alternate dilations were supported with retroperfusion; the unsupported inflations served as the control inflations. Synchronized retroperfusion was performed by pumping autologous femoral artery blood by means of an electrocardiogram-triggered retroperfusion pump into the great cardiac vein through a triple lumen 8.5F balloon-tipped retroperfusion catheter inserted percutaneously from the right internal jugular vein. Clinical symptoms, hemodynamics and two-dimensional echocardiographic wall motion abnormalities were analyzed. Retroperfusion was associated with a lower angina severity score (0.8 +/- 1 vs. 1.2 +/- 1) and delay in onset of angina (53 +/- 31 vs. 37 +/- 14 s; p less than 0.05) compared with the control inflations. The magnitude of ST segment change was 0.11 +/- 0.14 mV with retroperfusion and 0.16 +/- 0.17 mV without treatment (p less than 0.05). The severity of left ventricular wall motion abnormality was also significantly (p less than 0.01) reduced with retroperfusion compared with control (0.7 +/- 1.4 [hypokinesia] vs. -0.3 +/- 1.6 [dyskinesia]). There were no significant changes in hemodynamics, except in mean coronary venous pressure, which increased from 8 +/- 3 mm Hg at baseline to 13 +/- 6 mm Hg with retroperfusion. Four patients required prolonged retroperfusion for treatment of angioplasty-induced complications. The mean retroperfusion duration in these patients was 4 +/- 2 h (range 2 to 7). In the three patients who underwent emergency bypass surgery, the coronary sinus was directly visualized during surgery and found to be without significant injury. There were no major complications. Minor adverse effects were transient atrial fibrillation (n = 2), jugular venous catheter insertion site hematomas (n = 4) and atrial wall staining (n = 1), all of which subsided spontaneously. Thus, retroperfusion significantly reduced and delayed the onset of coronary angioplasty-induced myocardial ischemia and provided effective supportive therapy for failed and complicated angioplasty.

Aged↗

Validation of a digital angiographic model to quantitate autoregulatory vasodilation of the coronary system.

Compensatory vasodilation of the distal coronary vascular bed is the major autoregulatory mechanism in response to coronary stenosis. Using impulse response analysis (IRA) of digital angiographic time-density curves, myocardial contrast-transit was modelled as two-compartment system to obtain total coronary transit times (T) and microcirculation transit times (Tmicro) as parameters of flow (Q) divided by distribution volume (V) of the corresponding compartments. IRA parameters were compared with electromagnetic Q in eight dogs. At rest, Vmicro/V increased (P less than 0.02) from 0.69 +/- 0.08 in normal arteries (n = 25) to 0.86 +/- 0.06 in stenotic arteries (n = 24). With maximal vasodilation during hyperaemia, Vmicro/V was similar for normal (0.89 +/- 0.05; n = 19) and stenotic arteries (0.9 +/- 0.05; n = 18). There was a close linear (r = 0.88) correlation between 1/Tmicro and Q during hyperaemia. However, at rest with intact vasomotor tone, 1/Tmicro and Q were linearly related (r = 0.94; n = 12) only when Q was reduced below normal by tight stenosis; but the relationship became curvilinear in non-Q-limiting stenosed and normal arteries due to progressive decrease in Vmicro. Instead, resting 1/Tmicro demonstrated a very close linear correlation with coronary flow reserve (r = 0.95). We conclude that two-compartmental modelling of coronary contrast transit reflects stenosis-mediated autoregulatory vasodilation of the coronary microcirculation by a single measurement at rest.

Animals↗

Lack of sustained clinical improvement in an elderly population after percutaneous aortic valvuloplasty.

The hemodynamic and clinical results following 25 percutaneous aortic valvuloplasty (PAV) procedures on 24 patients are reported. The mean aortic gradient decreased from 66 +/- 23 to 40 +/- 15 mm Hg (p less than 0.001) and the mean valve area increased from 0.5 +/- 0.17 to 0.7 +/- 0.26 cm2 (p less than 0.001). Although the aortic gradient determined by both Doppler and direct measurement correlated well before PAV, the Doppler gradients determined 24 +/- 48 hours after the procedure were significantly higher than the directly measured gradients at the time of PAV. Ninety-two percent of patients were New York Heart Association class III or IV before PAV. Of the remaining 12 patients, 6 (50%) were classified as class II, 2 (17%) were class III, and 4 were (33%) class IV. Necropsy examination of the patient who died shortly after valvuloplasty revealed localized hematoma and tear in the anterior mitral valve leaflet. Smaller initial valve areas yielded smaller valve areas after PAV. Patients with greater valve areas following PAV showed greater functional improvement. Only 7 patients (29%) had at least 1 functional class improvement at the final follow-up. PAV can be performed relatively safely in elderly, moribund patients, although sustained improvement of functional status is not common. In this population, PAV should be limited to patients severely symptomatic in whom surgery is not an acceptable option.

Aged↗

Digital quantification eliminates intraobserver and interobserver variability in the evaluation of coronary artery stenosis.

A leading problem with subjective interpretation of coronary angiography is high intraobserver and interobserver variability. Four experienced angiographers independently determined percent diameter narrowing of 36 stenoses using 3 methods: by subjective analysis of single-frame cine film images (film), by subjective analysis of digitized nonenhanced single-frame images (digital), and by using a semiautomated digital caliper quantification system (Corona). The reproducibility of interpretations was assessed by comparison of estimated intraclass correlation coefficients. Digital and Corona readings correlated well with subjective interpretation of film (r greater than 0.85 for both). In contrast to Corona, the angiographers systematically overestimated the magnitude of stenoses in the intermediate (50 to 75%) range. Corona markedly improved intraobserver (p less than 0.005) and interobserver (p less than 0.001) reproducibility. Corona less frequently misclassified individual observations than did film when categories of less than 50%, 50 to 75% and more than 75% diameter stenosis were used (3.7% vs 31.5%, p less than 0.001). Our results suggest that digitization of a coronary angiogram in a 512 X 512 matrix has no significant adverse effects on the perception and quantification of stenosis by angiographers. Additionally, automatic measurement of coronary stenosis has 2 major advantages: It is accurate compared with a group of experienced angiographers and for the practical purpose of clinical decision-making, it eliminates intraobserver and interobserver variability.

Angiography↗

Fibrinolytic therapy of St. Jude valve thrombosis under guidance of digital cinefluoroscopy.

Fibrinolytic therapy is an alternative to urgent reoperation for patients with St. Jude prosthetic valve thrombosis, but requires an accurate method for repeated assessment of prosthetic function. Since the St. Jude valve is not well visualized by conventional cinefluoroscopy, digital subtraction techniques were developed that improved visualization of the value and allowed assessment of leaflet separation and velocity. A 74 year old woman with prosthetic valve thrombosis 5 years after St. Jude aortic valve placement had an opening angle of 58 degrees (normal range 10 to 13; n = 8) with a maximal opening velocity of 1.37 degrees/ms (normal range 2.46 to 2.93). The closing angle was 125 degrees (normal range 120 to 127) with a maximal closing velocity of 1.38 degrees/ms (normal range 2.24 to 3.60). The patient received 250,000 U of streptokinase intravenously, then 100,000 U/h for 72 hours. Improvement in auscultatory findings occurred at 12 hours; repeat digital cinefluoroscopy showed an opening angle of 20 degrees with a maximal velocity of 2.77 degrees/ms, and a closing angle of 126 degrees with a maximal velocity of 1.91 degrees/ms. Digital cinefluoroscopy 4 weeks after discharge on warfarin and dipyridamole therapy was unchanged. There have been no thromboembolic complications after 6 months of follow-up. Thus, digital cinefluoroscopy is a new noninvasive technique that permits accurate measurement of normal and abnormal St. Jude leaflet function. Intravenous streptokinase dissolution of prosthetic valve thrombosis under digital cinefluoroscopic guidance may be an acceptable alternative to emergency reoperation. The frequency and significance of residual subclinical leaflet dysfunction after fibrinolytic therapy and the indications for elective reoperation require further evaluation.

Aged↗