Effect of uncertainty components such as recalibration on the performance of quality control charts.

BACKGROUND: Uncertainty components (recalibration, new reagent lots, etc.) may be the source of random changes in the level of quality control (QC) values, thus causing false alarms. We propose a method for reducing false alarms. MATERIAL AND METHODS: Daily QC measurements of 22 biochemical quantities were recorded over 5 months, while methods and analyser showed no signs of malfunctioning. Each time series of QC values was subdivided according to reagent lot, electrolyte diluent or disposable electrode used. Analysis of variance (ANOVA) was used to examine whether mean levels changed significantly between subseries. For each quantity, the entire time series and each subseries were examined for autocorrelation. An X chart and an exponentially weighted moving average (EWMA) chart (or EWMAST [EWMA for stationary processes] in autocorrelated series) were calculated from the first 50 values of each series or subseries and applied to the whole series. Values falling outside the three standard deviation control limits were noted. RESULTS: In 22 out of 24 time series, the mean level differed significantly between subseries. These changes caused spurious autocorrelation. However, in 51.3 % of all subseries a significant autocorrelation could also be demonstrated. In total, 5.6 % and 29.1 % of all time series values fell outside the control limits of the X charts and the EWMA or EWMAST charts, respectively. These percentages were significantly reduced to 0.44 and 0.70 when the subseries-specific control charts were used. CONCLUSIONS: The mean level may change because of recalibrations or change of electrolyte diluent lot with subsequent false alarms. False alarms may be significantly reduced by revising QC charts when significant changes occur.

Albumins↗

Serial correlation of quality control data--on the use of proper control charts.

BACKGROUND: Biochemical quality control (QC) data have been reported to be autocorrelated. Serial correlation may increase the rate of false alarms if the traditional exponentially weighted moving average (EWMA) control chart to monitoring the process mean is used. False alarms are the focus of this paper, where an alarm is defined as the occurrence of a QC value outside the three standard deviation control limits. METHODS: Daily QC measurements of common biochemical (Vitros 500) and hematological (SF-3000 and Behring Coagulation Timer (BCT)) quantities were recorded during several months while methods and analyzers showed no signs of malfunctioning. The time series were examined for autocorrelation and the performance of the EWMAST chart was compared with that of the EWMA chart when autocorrelation was present. RESULTS: Many of the time series showed significant signs of autocorrelation. Using the EWMA chart to monitor the process mean, false alarms were noted for positively autocorrelated time series, while this was seldom the case when the EWMAST chart was used. For some quantities, the EWMAST chart gave alarms. However, when the process autocorrelation and therefore the limits of the control chart were updated, the alarms given by the EWMAST chart were reduced or disappeared. In some cases the mean level changed over time, which is expected due to calibrations. This problem will be the topic of a subsequent paper. CONCLUSIONS: Positive autocorrelation may be present in QC data. In this case the EWMAST chart should be used in place of the EWMA chart.

Algorithms↗

Image sharpness measurement in the scanning electron-microscope--part III.

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. Testing and proving that the instrument is performing at a satisfactory level of sharpness is an important aspect of quality control. The application of Fourier analysis techniques to the analysis of SEM images is a useful methodology for sharpness measurement. In this paper, a statistical measure known as the multivariate kurtosis is proposed as an additional useful measure of the sharpness of SEM images. Kurtosis is designed to be a measure of the degree of departure of a probability distribution. For selected SEM images, the two-dimensional spatial Fourier transforms were computed. Then the bivariate kurtosis of this Fourier transform was calculated as though it were a probability distribution. Kurtosis has the distinct advantage that it is a parametric (i.e., a dimensionless) measure and is sensitive to the presence of the high spatial frequencies necessary for acceptable levels of image sharpness. The applications of this method to SEM metrology will be discussed.

Artifacts↗