PubMed Health⌕ Search

Biomedical subjects

N G Campeau

Publications and source records attributed to N G Campeau.

17 recordsLinked to original sources

Magnetic resonance angiography at 3.0 Tesla: initial clinical experience.

Magnetic resonance (MR) angiography has undergone significant development over the past decade. It has gone from being a novelty application of MR with limited clinical use to replacing catheter angiography in some clinical applications. One of the principal limitations inherent to all MR angiographic techniques is that they remain signal limited when pushed to the limits of higher resolution and short acquisition time. Developments in magnetic gradient hardware, coil design, and pulse sequences now are well optimized for MR angiography obtained at 1.5-T main magnetic field (B-field) strength, with acquisition times and imaging matrix size near their optimal limits, respectively. Recently, the United States Food and Drug Administration (FDA) approved use of clinical magnetic resonance imaging with main magnetic field strengths of up to 4 T. Before FDA approval, use of MR with magnetic field strengths much greater than 1.5 T was essentially reserved for investigational or research applications. The main advantage of high B-field imaging is a significant improvement in the signal-to-noise ratio (SNR), which increases in an approximately linear fashion with field strength in the range of 1.5 to 3.0 T. This increased SNR is directly available when performing MR angiographic acquisitions at higher magnetic field strengths, allowing for better resolution and conspicuity of vessels with similar acquisition times. Little has been reported on the benefits of performing MR angiography at magnetic field strengths >1.5 T. The purpose of this article is to summarize our current experience with intracranial and cervical MR angiographic techniques at 3.0 T.

Equipment Design↗

Mild cognitive impairment and Alzheimer disease: regional diffusivity of water.

PURPOSE: To compare the regional diffusivity of water in the brains of normally aging elderly people and patients with mild cognitive impairment (MCI) or Alzheimer disease. MATERIALS AND METHODS: Magnetic resonance images were obtained in 21 patients with Alzheimer disease, 19 patients with MCI, and 55 normally aging elderly control subjects without evidence of cognitive impairment. Regions of interest were drawn to compare the apparent diffusion coefficient (ADC) and the anisotropy index (AI) in frontal, parietal, temporal, occipital, anterior, and posterior cingulate white matter (WM), and the thalami and hippocampi. RESULTS: Hippocampal ADC was higher in MCI and Alzheimer disease patients than in control subjects. ADC of the temporal stem and posterior cingulate, occipital, and parietal WM was higher in Alzheimer disease patients than in control subjects. Except for occipital AI, which was lower in MCI patients than in control subjects, there were no differences in AI among the three groups for any of the regions. CONCLUSION: Hippocampal ADC was significantly different between control subjects and MCI patients, many of whom likely have preclinical Alzheimer disease. Elevation in hippocampal ADC may reflect early ultrastructural changes in the progression of Alzheimer disease.

Aged↗

MR imaging in comatose survivors of cardiac resuscitation.

BACKGROUND AND PURPOSE: The prognosis of comatose survivors is determined by clinical examination. Early laboratory indicators of poor prognosis (such as evoked potentials) have low sensitivity. The role of MR imaging as a confirmatory study was investigated. METHODS: We studied fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted (DW) imaging in 10 patients comatose after cardiac arrest. RESULTS: None of the 10 comatose patients had myoclonus status epilepticus or fixed, dilated pupils on neurologic examination, and none had abnormal somatosensory-evoked potentials. Eight patients showed diffuse signal abnormalities, predominantly in the cerebellum (n = 5), the thalamus (n = 8), the frontal and parietal cortices (n = 8), and the hippocampus (n = 9). One patient showed normal MR imaging results, and one patient had abnormalities in the thalamus and cerebellum and minimal abnormality on DW images; both later awakened. None of the patients with abnormal cortical structures on FLAIR MR images recovered beyond a severely disabled state. CONCLUSION: MR imaging in comatose survivors may parallel the pathologic findings in severe anoxic-ischemic injury, and extensive abnormalities may indicate little to no prospects for recovery. If confirmed, MR imaging may have a role as a prognosticating test in anoxic-ischemic coma.

Adult↗

Regional metabolic patterns in mild cognitive impairment and Alzheimer's disease: A 1H MRS study.

BACKGROUND: Mild cognitive impairment (MCI) is a recently described transitional clinical state between normal aging and AD. Assuming that amnestic MCI patients had pathologic changes corresponding to an early phase and probable AD patients to a later phase of the disease progression, the authors could approximate the temporal course of proton MR spectroscopic (1H MRS) alterations in AD with a cross-sectional sampling scheme. METHODS: The authors compared 1H MRS findings in the superior temporal lobe, posterior cingulate gyri, and medial occipital lobe in 21 patients with MCI, 21 patients with probable AD, and 63 elderly controls. These areas are known to be involved at different neurofibrillary pathologic stages of AD. RESULTS: The N-acetylaspartate (NAA)/creatine (Cr) ratios were significantly lower in AD patients compared to both MCI and normal control subjects in the left superior temporal and the posterior cingulate volumes of interest (VOI) and there were no between-group differences in the medial occipital VOI. Myoinositol (MI)/Cr ratios measured from the posterior cingulate VOI were significantly higher in both MCI and AD patients than controls. The choline (Cho)/Cr ratios measured from the posterior cingulate VOI were higher in AD patients compared to both MCI and control subjects. CONCLUSION: These findings suggest that the initial 1H MRS change in the pathologic progression of AD is an increase in MI/Cr. A decrease in NAA/Cr and an increase in Cho/Cr develop later in the disease course.

Aged↗

An evaluation of JPEG and JPEG 2000 irreversible compression algorithms applied to neurologic computed tomography and magnetic resonance images. Joint Photographic Experts Group.

We performed visual comparison of 200 head magnetic resonance (MR) and 200 head computed tomography (CT) images compressed at two levels using standard Joint Photographic Experts Group (JPEG) irreversible compression and a preliminary version of the JPEG 2000 irreversible algorithm. Blinded evaluations by neuroradiologists compared original versus either JPEG or JPEG 2000. We found that this version of JPEG 2000 did not perform as well as the current JPEG for head CTs, but for MR images, JPEG 2000 performed as well or better. Around 7:1 compression ratio seemed to be a conservative point where there was no perceptible difference.

Algorithms↗

Effects of a stereotactic headframe assembly on proton magnetic resonance spectroscopy.

The effects of a magnetic resonance-compatible stereotactic headframe assembly on single voxel proton magnetic resonance spectroscopy (MRS) were investigated. Multiple stimulated echo acquisition mode (STEAM) spectra were obtained within a commercially available brain metabolite phantom placed within the headframe assembly (Leksell, Model G). All acquisition parameters were kept constant, except voxel location. Maximal distortion occurred for voxels acquired in the immediate vicinity of a headframe fixation pin, manifested by spectral broadening, changes in peak area and height and distortion of the baseline, rendering these acquisitions nondiagnostic. The range of this interaction was short, and a voxel acquired with nearest edge located 2.0 cm or greater from the fixation pin tip produced NAA/Cr, Cho/Cr and mI/Cr ratios differing by less than 7.5% from a spectrum obtained at the phantom center. The feasibility of performing single voxel MRS with a stereotactic headframe in place is demonstrated.

Brain Mapping↗

Ultrasound appearance of synovial osteochondromatosis of the shoulder.

This case report demonstrates the ultrasound appearance of synovial osteochondromatosis of the shoulder, along with plain film radiographic, computed tomographic, and pathologic correlation. Because of recent renewed interest in the use of ultrasonography in the evaluation of musculoskeletal disease, such as rotator cuff arthropathy or suspected intra-articular loose body, opportunities to diagnose synovial osteochondromatosis with this modality have become more frequent.

Chondromatosis, Synovial↗

Hippocampal transverse relaxation times in patients with Alzheimer disease.

PURPOSE: To determine whether hippocampal relaxation times in magnetic resonance (MR) imaging differ between patients with probable Alzheimer disease and elderly control subjects with normal cognition. MATERIALS AND METHODS: MR imaging relaxation times were measured in the head and body of the right and left hippocampi in 123 subjects: 62 patients with Alzheimer disease (44 women, 18 men; age range, 65-89 years) and 61 elderly control subjects without cognitive impairment (39 women, 22 men; age range, 65-89 years). Hippocampal relaxation times were correlated with clinical status (patient vs control subject), age, sex, laterality (right vs left), and location within the hippocampus (body vs head). The hippocampal T2 value was correlated with the severity of disease in the patients. RESULTS: No statistically significant difference in the relaxation times was found between the two clinical groups for the analysis of the right versus left hippocampi and the hippocampal head versus body. In both patients and control subjects, no correlation was found between T2 measurements and age or sex. Twenty-seven patients had a clinical dementia rating (CDR) score of 0.5 (very mild dementia), 21 patients had a CDR score of 1.0 (mild dementia), and eight patients had a CDR score of 2.0 (moderate dementia). The CDR score was not available in six patients. No statistically significant association between T2 values and severity of disease was observed. CONCLUSION: MR relaxation time measurements in the hippocampus are not useful for the detection of Alzheimer disease.

Aged↗

Prostatic calcifications detected on Tc-99m MDP bone scan mimicking bone metastasis.

Uptake of Tc-99m MDP tracer was noted within prostatic calcifications in a 48-year-old man with no known malignancy who underwent a three-phase bone scan for left knee and thigh pain. Routine anterior and posterior views of the pelvis demonstrated focal tracer uptake within the right pubic bone, which mimicked a metastatic lesion. Additional imaging showed the uptake to be extraosseous and localized within the prostate in a distribution similar to the extensive prostatic calcifications seen on the corresponding plain film and computed tomography examinations of the pelvis. This unusual presentation illustrates another potential artifact that may be present in scintigraphic bone imaging of the pelvis.

Bone Neoplasms↗

MR imaging of the abdomen with a phased-array multicoil: prospective clinical evaluation.

PURPOSE: To prospectively compare use of a phased-array multicoil and a conventional body coil in abdominal MR imaging. MATERIALS AND METHODS: Thirteen patients (seven men, six women; mean age, 55 years) underwent imaging with a phased-array multicoil and with a conventional body coil. Four pulse sequences were used: T2-weighted spin echo (SE), magnetization-prepared gradient-recalled echo (GRE), breath-hold fast SE, and echo planar (EP). RESULTS: Lesion detection improved the most on fast SE, multicoil-acquired images. Signal-to-noise ratio (S/N) increased 64% with fast SE (P = .0005) and EP (P < .0109) sequences. Contrast-to-noise ratio (C/N) doubled (P < .05) with T2-weighted SE sequences. Lesion conspicuity improved on multicoil-acquired images with all fast sequences (magnetization-prepared GRE, P = .015; fast SE, P = .002; EP imaging, P = .013). There was little difference in respiratory and vascular artifact. Depiction of most abdominal structures improved (P < .01). CONCLUSION: Use of the phased-array multicoil provides better MR images of the abdomen than does use of a conventional body coil.

Abdomen↗

Magnetization transfer contrast on gradient echo MR imaging of the temporomandibular joint.

Thirty-nine temporomandibular joints (TMJ) from 20 patients with suspected internal derangements were imaged by a 1.5 T MR imager. The on-resonance binomial magnetization transfer contrast (MTC) pulse was applied to gradient echo images with a dual receiver coil (9 s/section). With the use of an opening device, a series of sequential images were obtained at increments of mouth opening and closing. The tissue signal intensities with (Ms) and without (Mo) MTC were measured and subjective image analysis was performed. Compared with the standard images, MTC technique provided selective signal suppression of disks. The average of Ms/Mo ratio of the disks (0.56) was lower than that of the retrodiskal pad (0.79) and of the effusion (0.89). With MTC technique, fluid conspicuity was superior to standard image. However, no significant superiority was found in disk definition subjectivity.

Adolescent↗

Tongue displacement: visualization with rapid tagged magnetization-prepared MR imaging.

The authors describe a technique to depict tongue muscle displacement with tagged magnetization-prepared gradient-recalled echo magnetic resonance imaging. Three Japanese volunteers (three men, aged 31-36 years) were studied while they articulated specific sounds. Each image was obtained in less than 2 seconds without need for gating. Displacement and alteration of the tags within the tongue muscle during phonation were clearly visible. The technique may prove useful in the study of phoniatric pathophysiology.

Adult↗

Magnetic resonance imaging of pelvic floor relaxation: dynamic analysis and evaluation of patients before and after surgical repair.

OBJECTIVE: To evaluate structures involved in pelvic support using conventional and snapshot magnetic resonance imaging (MRI). METHODS: We used conventional spin-echo MRI and dynamic snapshot GRASS MRI at various levels of the Valsalva maneuver to describe and quantitate the anatomy of pelvic floor relaxation and to assess anatomical changes produced by surgical repair. Ten female volunteers were evaluated to define normal anatomy and reference measurements. Five women with pelvic floor relaxation were evaluated before and after surgical repair. RESULTS: Static and dynamic MRI were more sensitive than clinical pelvic examination in assessing and grading pelvic floor relaxation. Quantitative results showed widening of the levator hiatus and more vertical lie of the levator plate postoperatively. Descent of the pelvic organs on maximal straining postoperatively was the same as that in normal volunteers. The posterior urethrovesical angle on MRI was more than 110 degrees in 14 of 15 continent subjects. CONCLUSIONS: Magnetic resonance imaging may be valuable in analyzing and assessing pelvic floor relaxation and in understanding anatomical changes occurring before and after surgical repair. The increased sensitivity of MRI in grading prolapse may make it useful in evaluating women with symptoms of pelvic floor relaxation but who have negative findings on clinical examination.

Adult↗

Rapid T1 estimation using tagged magnetization-prepared gradient-echo MR imaging.

A technique for estimation of the longitudinal relaxation time of a large homogeneous object with an acquisition time of 4 s or less was developed by combining spatially selective rf tagging pulses with a T1-weighted magnetization-prepared gradient-echo sequence. Multiple 5-mm-wide tagged areas are laid orthogonal to the imaging section of interest. The contrast between each tag and the untagged regions differs because each tag is produced at a different time. The T1 value is determined from the nulling time at which tagged and untagged areas have no contrast.

Adipose Tissue↗

T1-weighted snapshot gradient-echo MR imaging of the abdomen.

Magnetization-prepared ultrashort-repetition-time (snapshot) gradient-echo imaging is a technique of magnetic resonance (MR) imaging with many potential applications. In the application of this technique to abdominal imaging, the effects on contrast of phase-encoding order, resolution, preparation-phase inversion time, and data-acquisition flip angle were predicted and then demonstrated with images obtained in examinations of 22 patients. In the analysis of 36 liver lesions, snapshot images were compared with corresponding T1-weighted spin-echo images on the basis of signal-to-noise ratio (S/N) of liver and contrast-to-noise ratio (C/N) between liver and lesion. Snapshot MR imaging produced abdominal images with 192 (or 256) x 256 resolution, negligible motion artifact, and C/N 1.29 times (+/- 0.48) higher than that in T1-weighted spin-echo imaging. Acquisition times were 13 seconds or less, short enough for imaging during suspended respiration. Also, use of a phased-array multicoil further improves the S/N in snapshot images without acquisition-time penalty.

Abdomen↗

Tracking motion with tagged rapid gradient-echo magnetization-prepared MR imaging.

A technique for rapid assessment of tissue motion was developed by combining spatially selective radio-frequency tagging pulses with centric phase-encoding view ordering in a T1-weighted, magnetization-prepared gradient-echo acquisition sequence. This sequence allowed labeling and tracking of tissue motion with single-image acquisition times of less than 3 seconds. Multiple tagged bands 3mm thick were superimposed orthogonal to the imaging plane. Motion in the interval between tagging and the start of image acquisition could then be precisely determined. The technique was evaluated with phantom studies and then applied to human volunteers for assessment of skeletal muscle motion, phonation, and pelvic floor motion.

Humans↗

Imaging of hydrogel episcleral buckle fragmentation as a late complication after retinal reattachment surgery.

Hydrogel encircling bands were introduced in the early 1980s as a product that was superior to bands composed of silicone rubber or silicone sponge for the surgical treatment of retinal detachment. Late complications consisting of orbital swelling and diplopia requiring band removal began to be reported in the early 1990s. Pathologic studies of these expanded fragments of hydrogel material after removal showed in vivo hydrolysis with foreign body reaction and dystrophic calcification. We report the imaging findings in five patients in whom this late complication developed. Hydrogel fragmentation has a characteristic imaging appearance consisting of a circumferential orbital mass associated with rim enhancement. This appearance should prompt inquiries regarding previous scleral buckle procedures with hydrogel bands. Familiarity with this appearance will avoid misinterpretation and unwarranted biopsy before band removal.

Aged↗