PubMed Health⌕ Search

Biomedical subjects

N Hersek

Publications and source records attributed to N Hersek.

14 recordsLinked to original sources

Bilateral bifid mandibular condyle.

Bilateral bifid mandibular condyles are rare and may appear as a congenital or developmental anomaly. A case of bilateral bifid mandibular condyles is reported. The patient had no history of trauma and no link was apparent with respect to the patient's medical history. In this case, the condition was an incidental panoramic radiographic finding. Magnetic resonance imaging findings revealed bilateral anterior disc displacement without reduction. The radiographic appearance of this anomaly and the literature on bilateral bifid condyles are reviewed.

Adult↗

Comparison of microleakage properties of three different filling materials. An autoradiographic study.

The aim of this study was to compare the microleakage behaviour of three restorative materials using the autoradiographic method. The study was accomplished in vitro using freshly extracted human molars and a Ca45 radioisotope and autoradiography. Twenty-seven molar teeth were divided into three experimental groups of seven specimens each. Class II cavities were prepared at the mesio-occlusal aspect and restored with amalgam and two different composite resins. The restorations were finished, thermocycled and tested for microleakage, using the Ca45 radioisotope. The results were analysed using the Kruskal-Wallis analysis test. Amalgam exhibited more leakage compared with composite resins. However the differences among the leakage behaviours of three filling materials were not statistically significant (P=0.064).

Autoradiography↗

Effect of different acid treatments on a porcelain surface.

The objective of this study was to determine the effect of selected surface treatments on the surface texture of a feldspathic porcelain. The three different etchant treatments were, acidulated phosphate fluoride (APF) applied for 10 min and hydrofluoric acid (HF) applied for 1 and 4 min. After acid treatment, half of the specimens from each group were cleansed with water and others were subjected to ultrasonic cleaning and then dried. Half of the specimens cleansed with two different methods were treated with silane. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to characterize the effects of such treatments. Etching with APF displays shallow patterns. Etching for 1 min with HF displays deep channels, pores and precipitates on the surface and as the etching time increased these channels were replaced by larger channels. EDS analyses show that the crystalline precipitates on the etched surfaces, which were not readily soluble in water, were the reaction products of Na, K, Ca, Al, etc. HF displayed a more roughened surface than the APF gel. However, the precipitates remain on the surface after acid application, they can only be removed by ultrasonic cleaning and cannot be removed by rinsing.

Acid Etching, Dental↗

Comparision of diametral tensile strength of microwave and oven-dried investment materials.

STATEMENT OF PROBLEM: Microwave drying technique for investment materials is believed to be timesaving by accelerating the elimination of free water content. PURPOSE: This study compared the diametral tensile strength of 4 investment materials used in removable partial denture framework fabrication. The investment materials were subjected to microwave and conventional oven drying at different time intervals. MATERIAL AND METHODS: Type III partial denture casting investments (Wirovest, Wiroplus, Biosint, PH2) were tested. A total of 160 specimens were prepared in cylindrical form at a height of 40 mm and a diameter of 20 mm, in accordance with the manufacturers' recommendations. Forty specimens were prepared from each product; 20 specimens were dried at 230 degrees C for 1 hour in an electric furnace, the other 20 were dried in a microwave oven for 10 minutes at 600 W. The dried specimens were tested at 2- and 4-hour intervals in diametral compression at a crosshead speed of 0. 5 cm/min. RESULTS: The microwave drying technique resulted in greater diametral tensile strength values for all investment materials. CONCLUSION: Within the limitations of this study, microwave drying of type III dental investment materials at 600 W for 10 minutes was, apart from strengthening the material, timesaving for the dental laboratory.

Analysis of Variance↗

Effect of five woven fiber reinforcements on the impact and transverse strength of a denture base resin.

STATEMENT OF PROBLEM: Fracture strength of denture base resins is of great concern, and many approaches have been used to strengthen acrylic resin dentures. PURPOSE: This study measured the effect of 5 fiber strengtheners on the fracture resistance of denture base acrylic resin material. Impact strength, transverse strength, deflection, and elasticity modulus values of a heat-polymerized denture base resin (Trevalon), reinforced with glass, carbon, thin Kevlar, thick Kevlar, and polyethylene fibers in woven form were studied. MATERIAL AND METHODS: One hundred acrylic resin test specimens reinforced with woven fibers were fabricated. The control group consisted of 20 specimens with no fiber reinforcement. For the impact strength test, a Charpy-type impact tester was used. Transverse strength was assessed with a 3-point bending test by using a screw-driven mechanical testing machine. Ten specimens were used for each test. RESULTS: The highest impact test values were produced by polyethylene-reinforced group, and the lowest values were obtained from specimens containing no fibers. There were significant differences among the test groups, but no significant differences in transverse strength were found. The lowest transverse strength values were obtained for specimens strengthened with polyethylene fibers, which also insignificantly decreased transverse strength of the acrylic resin. CONCLUSION: The impact strength of denture base acrylic resins was increased with fibers in woven form. Tested fibers did not have a significant effect on the transverse strengths.

Analysis of Variance↗

Color stability of denture base acrylic resins in three food colorants.

STATEMENT OF PROBLEM: Three commonly used artificial dyes in food technology are erythrosine, tartrazine, and sunset yellow. PURPOSE: The color stability of 5 commercially available denture base acrylic resins (QC-20, Meliodent, Trevalon, Trevalon High, and Lucitone) was studied in vitro. METHODS: The specimens were exposed to 3% erythrosine, tartrazine, and sunset yellow solutions at 23 degrees C +/- 1 degrees C. Color changes were determined with a computer-controlled spectrophotometer. Five specimens from each material were processed, and initial color measurements were made after 1, 3, and 6 months of exposure to the staining solutions. Finally, the color stability was quantitatively measured again, and color differences (DeltaE) were calculated. RESULTS: For the observations made in 1, 3, and 6 months intervals, the specimens that exhibited the least color change were in the sunset yellow solution. The greatest color changes observed according to the National Bureau of Standards unit system were Lucitone (2.71) in erythrosine solution, Lucitone (2.54), QC-20 (1.71) in tartrazine solution, and QC-20 (1.66) in sunset yellow solution. The changes in the other acrylic resins in the 3 solutions were slight and at trace level. CONCLUSIONS: All materials tested were acceptable from the standpoint of color stability for long-term exposure to these food colorants.

Acrylic Resins↗

Evaluation of colour and hardness changes of soft lining materials in food colorant solutions.

The aim of this study was to measure the colour stability and viscoelastic properties of three commercially available soft lining materials in vitro, by exposing them to 3% erythrosine, tartrazine and sunset yellow solutions. The colour changes were determined using a computer controlled spectrophotometer. The colour change of three soft lining materials--Molloplast B, Flexor and Coe Super Soft--were determined after 1, 3 and 6 months storage in three different food colorant solutions. The colour changes of Molloplast B was not noticeable. Only the initial colour value of Flexor was significantly different from the other time interval colour measurements. On the other hand, the colour difference of Coe Super Soft was found to be significantly different at all comparative time interval measurements (P<0.05). According to Shore A hardness values, Molloplast B had an initial hardness of 44 in all three solutions, and there was a slight increase after 6 months. Flexor had an initial hardness of 39, at the end of 6 months the hardness changed a little. Coe Super Soft was fairly hard after processing and Shore A hardness was initially 89 which increased to 95 later on. According to these results, only the hardness values of Coe Super Soft showed a statistically significant difference when compared using Wilcoxon signed rank test at the P<0.05 level. As a conclusion, silicon type soft lining material seems to be more resistant to colour change and hardness than the acrylic type soft liners.

Acrylic Resins↗

Effect of muscle relaxation splint therapy on the electromyographic activities of masseter and anterior temporalis muscles.

The purpose of this study was to compare the effectiveness of splint therapy on the electromyographic activity of masticatory muscles (anterior temporalis and masseter) before and after the application of a muscle relaxation splint. Electromyography recordings from the masseter and anterior temporalis muscles were analyzed quantitatively during maximal biting in the intercuspal position both before and after treatment without a splint. Fourteen patients whose chief complaint was masticatory muscle pain were selected for the study. After the initial evaluations muscle relaxation splints were applied, and the patients were instructed to use the splints for 6 weeks. Surface electromyographic recordings were taken from each patient before the beginning of clinical therapy and after 6 weeks of wearing the splints. The data obtained were analyzed through paired sample t tests and Wilcoxon's signed rank tests. The results of the study were as follows: (1) the electromyographic activity of the two muscles during maximal biting was not markedly changed after the muscle relaxation splint was used; and (2) the changes observed in electromyographic activity of the involved and noninvolved sides were insignificant as well.

Adult↗

Evaluation of titanium in oral conditions and its electrochemical corrosion behaviour.

Due to its excellent biocompatibility and good mechanical properties, titanium has been used successfully in dentistry for many years. In this study, complete dentures with titanium palatal plates were applied to 10 patients who were in need of upper dentures. The clinical performance of cast titanium palatal plates was determined over a period of 6 months. No increase in accumulation of denture plaque nor mucosa irritation was observed. After the above period, the electrochemical corrosion behaviour of cast titanium and chromium-cobalt palatal plates were compared with the titanium plates that were not left in an oral environment after casting. For the electrochemical corrosion tests, a corrosion cell was designed and artificial saliva with lactic acid was used, with the temperature during the tests being about 37 degrees C. The potential difference between the test sample and the saturated calomel electrode was measured, and after the determination of the rest potentials, the anodic potentiodynamic polarization curves were traced at a rate of 1 mV/s. From the standpoint of corrosion, the titanium plates used by the patients for a 6-month period corroded more than the titanium not used by the patients. This may be due to the casting and processing conditions and the effect of the oral environment.

Aged↗

Effect of anterior repositioning splints on the electromyographic activities of masseter and anterior temporalis muscles.

The effect of anterior repositioning (AR) splint therapy on masticatory muscle activity was investigated in seventeen patients with internal derangement; disk displacement with reduction in particular. Integrated electromyography (EMG) recordings from the masseter and anterior temporalis muscles were analyzed quantitatively during maximal biting in intercuspal position before and after eight week treatment period, EMG recordings were taken for each subject prior to the beginning of clinical therapy and final EMG recordings were made without AR splint to provide a standard for comparison. The results of the investigation revealed the following: 1. AR splint therapy did not cause any significant modification of the EMG activity in the recorded muscles during maximal biting in intercuspal position; 2. Before and after treatment the EMG activity from the masseter muscle was less than from the temporal muscle; 3. AR splint therapy resulted in reduction of the pain (88.2%) and jaw joint sounds (64.7%) and mean vertical opening which was 42.17 mm before treatment increased to 45.06 mm.

Adult↗

Effect of 4-META adhesive on the bond strength of different metal framework designs and acrylic resins.

The effect of relining the 4-META adhesive resin onto metal alloy of a partial denture framework was tested. Seventy-two metal frameworks with three different retentive patterns were designed. Half of the specimens were treated with 4-META, the other group was left untreated. Thirty-six specimens were first divided into three groups in which 12 samples had different designs of retention, i.e. mesh, ring-shaped and flat plane. Then, each different retentive design was divided into two groups and in one group Lucitone 199 and the other QC acrylic resin were processed. Finally they were subjected to shear test. While samples with adhesive exhibited greater bond strength than the others, samples without adhesive may be ranked in the order mesh, ring-shaped and flat planes with regard to shear bond strength. In samples with adhesive, the flat plane ones displayed better results. Statistically significant differences were observed in the relationships between the groups.

Acrylic Resins↗

The effect of weight loss of liquid on the diametral tensile strengths of various kinds of luting cements.

The role of water evaporation from the liquids of the cements were tested, and the effect of this loss on their strength was evaluated for 0, 10, 20 and 30 minute, intervals. After 30 minutes the evaporation of liquid from the cements was so high that they lost their luting consistency. The data suggests that the highest weight loss was with polycarboxylate cement liquids, with glass-ionomer and zinc phosphate cement liquids following respectively. However, when diametral tensile strength test values were evaluated it was determined that glass-ionomer exhibited the highest resistance to fracturing and zinc phosphate the lowest. Upon examination of samples which were fractured, while polycarboxylate and glass-ionomer cracked and split into large fragments, zinc phosphate cements fractured into a multitude of small pieces. On the basis of this study, it appears that the manufacturers' recommendations about the powder-to-liquid ratio and the mixing procedures is confirmed particularly and should be adhered to for optimal results.

Analysis of Variance↗

Comparison of stress distribution around vertical and angled implants with finite-element analysis.

The distribution of stress around implants placed in the first molar region of the mandible was biomechanically analyzed in a two-dimensional mathematical model. Two types of implants, vertical and angled, were subjected to a vertical load of 100 N and a horizontal load of 50 N in turn. The magnitudes and contours of compressive and tensile stress within the surrounding bone were determined. For the sake of comparison, maximal compressive stress and maximal tensile stress at the surrounding bone were calculated. There were no measurable differences in stress values and contours when a horizontal load was applied to the vertical and angled implants. However, with the vertical loading, the compressive stress values were five times higher around the cervical region of the angled implant than around the same area in the vertical implant.

Compressive Strength↗

Water sorption and dimensional changes of denture base polymer reinforced with glass fibers in continuous unidirectional and woven form.

PURPOSE: The aim of this study was to determine the dimensional accuracy and water sorption of a denture base polymer that was reinforced with glass fibers in continuous unidirectional and woven form in different weight fractions. MATERIALS AND METHODS: Ten rhombic brass plates were prepared with reference points, and 70 heat-cured denture base polymer specimens were produced using these brass models. Ten of 70 were used for controls, and 60 were reinforced with glass fibers in continuous parallel and woven form. The dimensional changes of polymer and fiber-reinforced composite specimens after processing, drying for 4 days at 37 degrees C, and storage in 37 degrees C water for 90 days were calculated by the change of the distance vector. The measurements were made between the reference points on the specimens and were compared with those on the brass model at 4 different stages. The water sorption calculations were made at 10 different time intervals on 70 specimens, which were immersed in a 37 degrees C distilled water bath and weighed. RESULTS: The polymerization shrinkage and water sorption of denture base polymers is lower when the specimens are reinforced with glass fibers in continuous unidirectional and woven form. The highest fiber content showed the smallest dimensional change (0.069 mm, or 0.25%), and the unreinforced group showed the largest change (0.139 mm, or 0.54%). Water sorption occurred mainly during the first 14 days. CONCLUSION: As the fiber content increases, the dimensional change and water sorption decrease.

Absorption↗