PubMed Health⌕ Search

Biomedical subjects

N Higuchi

Publications and source records attributed to N Higuchi.

69 records · Page 4Linked to original sources

Origin of slow conformer conversion of triostin A and interaction ability with nucleic acid bases.

The n.m.r. pattern of triostin A in weakly polar solvents was explained by the presence of two symmetrical conformers. Its S-benzyl derivative still shows the n.m.r. pattern of two conformers, while des-N-tetramethyltriostin A, which lacks the N-methyl groups, gives one conformer. Therefore the slow interconversion of two conformers arises from the cis-trans isomerization of the N-methyl peptide bonds, but not from the reversal of the chirality around the S-S bond. Only one of the two conformers of triostin A interacts with adenosine and guanosine derivatives. Des-N-tetramethyltriostin A can also interact with the purine nucleosides, but more preferentially with the adenosine derivative.

Adenosine↗

High-level expression of naked DNA delivered to rat liver via tail vein injection.

BACKGROUND: High levels of foreign gene expression in mouse hepatocytes can be achieved by rapid tail vein injection of a large volume of a naked DNA solution, the 'hydrodynamics-based procedure'. Rats are more tolerant of the frequent phlebotomies required for monitoring blood parameters than mice, and thus are better for some biomedical research. METHODS: We tested this technique for the delivery of a therapeutic protein in normal rats, using a rat erythropoietin (Epo) expression plasmid vector, pCAGGS-Epo. RESULTS: We obtained maximal Epo expression when the DNA solution was injected in a volume of 25 ml (approximately 100 ml/kg body weight) within 15 s. We observed a dose-response relationship between serum Epo levels and the amount of injected DNA up to 800 microg. Using quantitative real-time PCR, the vector-derived Epo mRNA expression was mainly detected in the liver. When a lacZ expression plasmid was injected similarly, beta-galactosidase was exclusively detected in the liver, mainly in hepatocytes. Toxicity attributable to the technique was mild and transient, as assessed by histochemical analysis. Epo gene expression and erythropoiesis occurred with Epo gene transfer in a dose-dependent manner, and persisted for at least 12 weeks, the last time point examined. Repeated administration of the plasmid DNA also effectively led to erythropoiesis. CONCLUSIONS: These results demonstrate that gene transfer into the liver via rapid tail vein injection can easily be achieved in the rat, which is more than 10 times larger than the mouse, and has significant value for gene function analysis in rats.

Animals↗

Phase-encode order and its effect on contrast and artifact in single-shot RARE sequences.

Substantial manipulation of tissue contrast can be achieved by varying the order in which phase-encode values are applied to individual echoes within a 128-echo single-shot rapid acquisition relaxation enhanced (RARE) sequence. Appropriate ordering can then permit imaging of short T2 species like muscle and white matter with single-shot RARE. For sequential phase encoding with an arbitrary initial phase-encode value, the timing of the zero phase (ZP) encoded echo is found to be analogous to the echo time (TE) of standard spin-echo sequences. This is demonstrated qualitatively with human brain images and is verified quantitatively with NiCl2 phantoms by correlating the time constant for signal decay with ZP echo time, with transverse relaxation times T2, as obtained with a 128-echo Carr-Purcell-Meiboom-Gill (CPMG) imaging sequence. Banding artifacts accompanying the discontinuous traverse through K space are experimentally demonstrated in a rectangular phantom and expressions are developed for determining the dependence of this artifact on the phase-encode gradient increments and durations, the ZP echo number, echo spacing, and T2. Simulations based on the expressions are shown to be useful for characterizing the observed "banding" artifacts perpendicular to the phase-encode direction and for predicting the extent of tissue-tissue overlap to be expected with the use of this ultrafast rf echo planar imaging method.

Brain↗

Development and evaluation of a radiological reporting system for use with a personal computer.

A computer-assisted radiological reporting system (CRRS) was developed for the efficient management and effective use of a database of radiological information. The system consists of a computer terminal linked to an HIS, a reporting console and a personal computer in the local area network of the radiology department, and a radiography care reader which transfers basic data on the patient from the HIS to the CRRS. The patient's name, hospital ID number, sex and date of birth, the department from which the patient has been referred, in-patient/out-patient status and the procedure needed are recorded on magnetic cards (radiography cards) issued to radiology patients. The system has been successfully used in all diagnostic procedures for 8 months: 16,300 reports have been printed out and stored. The system has made it possible to implement the complete radiological reporting procedure for clinical applications, and the required data can easily be retrieved and used. It has proved to be quite easy to use CRRS to obtain diagnostic histories, and the improved efficiency of the reporting procedure has enabled the cost of a clerk typist to be eliminated.

Data Collection↗

EUS-guided endoscopic resection using band ligation of oesophageal granular cell tumour: report of a case.

A 60-year-old Japanese man was referred for treatment of a polypoid oesophageal tumour. Radiographic examination of the upper gastrointestinal tract disclosed a nodule with central depression in the lower esophagus. By endoscopy the nodule was yellowish and appeared submucosal. Endoscopic ultrasonography demonstrated a hypoechoic solid tumour limited in submucosa without lymph node involvement. Endoscopic resection using band ligation was performed under guidance by endoscopic ultrasonography. By histologic examination the tumour consisted of large cells arranged in nests. These cells had abundant granular cytoplasm and small round nuclei. They expressed S-100 protein and were CD68, and periodic acid-Schiff positive. No expression of alpha-smooth muscle actin was noted. The tumour was limited in submucosa. Findings were consistent with complete endoscopic resection. This report may be the first concerning an oesophageal granular cell tumour successfully treated with EUS-guided endoscopic resection using band ligation.

Biopsy, Needle↗

Rapid MR imaging of the pediatric brain using the fast spin-echo technique.

PURPOSE: To evaluate diagnostic reliability and to establish optimal scanning techniques of a recently developed Fast Spin-echo MR pulse sequence that allows rapid proton density-weighted and T2-weighted imaging. METHODS: We compared lesion conspicuity and signal intensity measurements on Fast Spin-echo and conventional spin-echo sequences in 81 patients ranging from 1 week to 25 years in age on a 1.5-T MR unit. A total of 28 Fast Spin-echo dual-echo images (14 slice locations) were obtained in 2:08 minutes with a 256 x 128 matrix or in 3:12 minutes with a 256 x 192 matrix at a TR of 2000 msec and two excitations. RESULTS: Lesion conspicuity and characterization on Fast Spin-echo images compared favorably with conventional spin-echo images in our series when pseudo-TEs of 15 and 90 msec were employed for proton density-weighted and T2-weighted images, respectively. Fast Spin-echo images yielded diagnostic information in four nonsedated patients whose conventional spin-echo images were either degraded by motion or unobtainable. Fat signal remained bright on T2-weighted Fast Spin-echo images. Magnetic-susceptibility effects were slightly reduced with Fast Spin-echo but did not pose any diagnostic problem in our series. CONCLUSION: Diagnostically reliable rapid dual-echo brain images can be obtained with Fast Spin-echo sequences.

Adolescent↗