PubMed Health⌕ Search

Biomedical subjects

N I Linnenbrügger

Publications and source records attributed to N I Linnenbrügger.

2 recordsLinked to original sources

Automated hybrid TACT volume reconstructions.

OBJECTIVES: To design, implement in Java, and evaluate a method and means for the automated localization of artificial landmarks in optical images for tuned-aperture computed tomography (TACT) that allows the replacement of radiographic with optical landmarks. METHODS: Circular, colored, optical landmarks were designed to provide flexibility with regard to landmark constellation, imaging equipment, and lighting conditions. The landmark detection was based on Hough transforms (HT) for ellipses and lines. The HT for ellipses was extended to enable selective detection of bright ellipses on a dark background and vice versa, and the number of irrelevant votes in the accumulator arrays was reduced. An experiment was performed in vitro to test the automated landmark localization scheme, verify registration accuracy, and measure the required computation time. RESULTS: A visual evaluation of the tomographic slices that were produced using the new method revealed good registration accuracy. A comparison to tomographic slices similarly produced by means of conventional TACT showed identical results. The algorithm ran sufficiently fast on standard hardware to allow landmark localization in "real time" during successive image acquisition in clinical applications. CONCLUSIONS: The proposed method provides robust automated localization of landmarks in optical images. Using a hybrid imaging system, TACT can now be clinically applied without manual interaction of a human operator and without radiopaque landmarks, which might cover anatomic details of diagnostic interest.

Algorithms↗

Implementation of a generalized TACT algorithm for arbitrary source-object distances.

OBJECTIVES: To implement, refine, and evaluate a generalized TACT reconstruction method that corrects for misregistration caused by uncontrolled variations in projective magnification, alleviates normalization artifacts at borders of backprojections, and exploits all available source information to minimize losses produced from projective truncations in three dimensions. METHODS: A new Java-based software application was designed and tested in vitro using clinically representive data derived from four titanium dental implants in a cadaver jaw segment. These implants were irradiated by an intra-oral X-ray machine from various angles and distances using a solid-state sensor producing 48 radiographs. Six radiopaque markers were attached to the segment facilitating inference of associated projection geometries from analyses of the distributions of their respective shadows as seen by the sensor. Three-dimensional (3D) images were produced using the new algorithm, and the results were compared with those obtained from existing code. RESULTS: Slices processed using the new program were corrected for magnification errors. The resulting 3D displays showed significantly reduced tomosynthetic blur relative to uncorrected counterparts. The new reconstructions also minimized known border artifacts and made use of all available information. These images demonstrated apparent details otherwise hidden or lost when comparably processed using the control algorithm. CONCLUSIONS: The new software reduces both misregistration and scaling artifacts in tomosynthetically reconstructed slices. Hence, these modifications are expected to increase diagnostic accuracy and facilitate the appropriate application of TACT to an enlarged set of diagnostic tasks as compared with earlier implementations of the method.

Algorithms↗