PubMed Health⌕ Search

Biomedical subjects

N Ichinose

Publications and source records attributed to N Ichinose.

At least 19 recordsLinked to original sources

Detection of mutual determinism between a pair of spike trains.

A method for detecting mutual deterministic dependence between a pair of spike trains is proposed. When it is assumed that a cell assembly, which is a subgroup of neurons processing a common task, is constituted as a dynamical system, then the mutual determinism between constituent neurons may be directly reflected in functional connectivity in the assembly. The deterministic dependence between two spike trains can be measured with statistical significance using a method of nonlinear prediction. Some examples of simulations are demonstrated in both deterministic and stochastic cases.

Action Potentials↗

Calcium level-responsive in-vitro zinc release from zinc containing tricalcium phosphate (ZnTCP).

The in vitro Zn release from tricalcium phosphate containing Zn (ZnTCP; 0.63, 6.17, and 12.05 Zn w/w%) was investigated. The rates of release from ZnTCP powders were measured in 25 mL of simulated body fluid (SBF) containing 10 mg/100mL Ca (SBF/H), 5 mg/100mL Ca (SBF/L), or no Ca (SBF/-) at pH 7.25, 37.0+/-0.1 degrees C. The release from 6 and 12% ZnTCP was initially very fast. The rate of release from ZnTCP decreased as the concentration of Ca in the dissolution media increased, but increased as concentration of Zn in TCP increased. The dissolution kinetics of ZnTCP followed the Hixon-Crowell equation at the initial stage of dissolution, and the initial dissolution rate constant (IDR) was calculated by the least-squares method. The effect of Ca concentration on percent IDR of ZnTCP suggested that Zn release from 0.6% ZnTCP was significantly high compared to that from 6 or 12% ZnTCP. The relationship between the amount of Ca precipitated and Zn release of various ZnTCP samples suggested that the release from 0.6% ZnTCP was significantly different compared to that from 6 and 12% ZnTCP, consistent with the data for percent Zn IDR. X-ray diffraction data suggested that 0.6% ZnTCP contained 5% hydroxyapatite, a low solubility material, which acted as seed crystal during the dissolution test.

Body Fluids↗

Preparation, solubility, and cytocompatibility of zinc-releasing calcium phosphate ceramics.

Zinc is an essential trace element with stimulatory effects on bone formation. Therefore, zinc was doped into beta-tricalcium phosphate to develop zinc-releasing biomaterials to promote bone formation. The zinc-doped beta-tricalcium phosphate, beta-tricalcium phosphate, and hydroxyapatite powders were mixed at a (Ca+Zn)/P molar ratio of 1.60, followed by sintering into a dense body at 1100 degrees C for 1 h. The sintered body was a composite ceramic consisting of zinc-doped beta-tricalcium phosphate and hydroxyapatite phases. The composite ceramic contained zinc oxide when the zinc content was higher than 1.20 wt %. The composite ceramic released zinc under pseudophysiological conditions. However, the release of calcium and phosphate decreased with an increase in zinc content in a range higher than 0.12 wt % owing to a decrease in solubility of the zinc-doped beta-tricalcium phosphate phase. Proliferation of osteoblastic MC3T3-E1 cells was significantly increased on the composite ceramic with a zinc content from 0.6 to 1.20 wt %, compared with those without zinc. When the zinc content was higher than 1.20 wt %, release of zinc from the zinc oxide caused cytotoxicity. Therefore, the zinc content of the composite ceramic must be <1.20 wt %.

Animals↗

Stimulatory effect of zinc-releasing calcium phosphate implant on bone formation in rabbit femora.

Although hydroxyapatite (HAP) and tricalcium phosphate (TCP) are currently used as bone graft substitutes or coatings on metallic prostheses because of their excellent biocompatibility and osteoconductivity, they do not stimulate bone formation or inhibit bone resorption. Zinc, an essential trace element in many animals, has a direct specific proliferative effect on osteoblastic cells and has a potent and selective inhibitory effect on osteoclastic bone resorption in vitro. Therefore, zinc-containing beta-tricalcium phosphate (ZnTCP) ceramics and composite ceramics of ZnTCP and HAP (ZnTCP/HAP) were implanted in the femora of New Zealand White rabbits for 4 weeks to promote bone formation. The implants were sintered ceramics with zinc contents of 0 (control), 0.063, 0.316 and 0.633 wt %. Histological and histomorphometrical investigation of the undecalcified sections revealed an increase by 51% (p =.0509) in the area of newly formed bone around the ZnTCP/HAP implants of 0. 316 Zn wt % compared with the control. Plasma zinc concentration was unchanged. An increased bone resorption on the endosteal surface was observed when ZnTCP and ZnTCP/HAP of 0.633 Zn wt % were implanted. To promote bone formation, the optimum zinc content of the calcium phosphate ceramics was therefore 0.316 wt %.

Animals↗

MR imaging of the enlarged endolymphatic duct and sac syndrome by use of a 3D fast asymmetric spin-echo sequence: volume and signal-intensity measurement of the endolymphatic duct and sac and area measurement of the cochlear modiolus.

BACKGROUND AND PURPOSE: In enlarged endolymphatic duct (EED) and sac (EES) syndrome, deformity of the EED and EES is congenital; however, hearing loss is acquired. To investigate the pathophysiology of progressive sensorineural hearing loss in EED and EES syndrome, we measured the volume of the EED and EES, the diameter of the EED and EES, the area of the cochlear modiolus, and the signal intensity of the EES and compared our findings against degree of hearing loss. METHODS: Thin-section MR images of 33 ears in 17 patients with EED and EES syndrome were studied. All studies were obtained on a 1.5-T MR unit using a quadrature surface phased-array coil. Heavily T2-weighted 3D fast asymmetric spin-echo images were obtained with a voxel size of 0.3 x 0.3 x 0.8 mm without zero-fill interpolation. Two radiologists traced the areas of the EED and EES manually, and the volume was calculated. The area of the cochlear modiolus, diameter of the EED and EES, and signal intensity of the EES were also measured by drawing regions of interest manually. The signal intensity ratio of EES/CSF was calculated. These measured values were compared against audiographic data, and the degree of linear correlation was determined. RESULTS: The volume of the EED and EES, the area of the modiolus, the diameter of the EED and EES, and the signal intensity of the EES did not show significant correlation with degree of hearing loss. CONCLUSION: These findings suggest that there is a microscopic area of damage or fragility in the inner ear not visible even with thin-section heavily T2-weighted MR imaging.

Adolescent↗

Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: basic experiments and clinical evaluation.

Magnitude subtraction and complex subtraction in dynamic contrast-enhanced three-dimensional magnetic resonance (3D-MR) angiography were compared using a phantom and 23 human subjects. In phantom studies, complex subtraction showed far better performance than magnitude subtraction, especially for longer echo times, with thicker slices, and without fat suppression. With complex subtraction, non-fat-suppressed studies showed contrast-to-noise ratios comparable to those in fat-suppressed studies. In human subjects, complex subtraction was superior to magnitude subtraction in 9 subjects, but comparable to magnitude subtraction in 14 subjects. There were no cases in which magnitude subtraction was superior to complex subtraction. Although the differences observed in human studies when complex subtraction was applied with thinner slices, shorter echo times, and the fat-suppression technique were not as pronounced as those seen in phantom studies, complex subtraction should be performed in dynamic contrast-enhanced 3D-MR angiography because there are no drawbacks in complex subtraction. Further research is necessary to assess the feasibility of dynamic contrast-enhanced 3D-MR angiography without fat suppression in human subjects using complex subtraction, as suggested by the results of phantom studies. If it is found to be feasible, dynamic contrast-enhanced 3D-MR angiography without fat suppression using complex subtraction may prove to be a robust technique that eliminates the need for shimming and can reduce the acquisition time. J. Magn. Reson. Imaging 1999;10:813-820.

Adult↗

MR imaging of the cochlear modiolus: area measurement in healthy subjects and in patients with a large endolymphatic duct and sac.

PURPOSE: To evaluate the cochlear modiolus with thin-section magnetic resonance (MR) imaging in healthy subjects and patients with a large endolymphatic duct and sac, and to assess whether the cochlea is normal or abnormal in patients with a large endolymphatic duct and sac. MATERIALS AND METHODS: MR images were obtained in 10 ears in five volunteers (group 1), 40 ears in 20 patients with bilateral sensory hearing loss (group 2), three ears in two patients with Mondini malformation (group 3), and 12 ears in seven patients with a large endolymphatic duct and sac (group 4). RESULTS: In groups 1 and 2, all modiolar areas were larger than 4.0 mm2. In group 3, each modiolus was smaller than 2.0 mm2. In group 4, modiolar areas were smaller than 2.0 mm2 in eight ears and were larger than 4.0 mm2 in four ears. CONCLUSION: Findings in this study confirm that a large endolymphatic duct and sac is frequently associated with modiolar deficiency, but the modiolar area is normal in some cases. This result does not support the recently proposed hypothesis that hearing loss with a large endolymphatic duct and sac is caused by the transmission of subarachnoid pressure forces into the labyrinth through a deficient modiolus.

Adolescent↗

High-resolution MR cisternography of the cerebellopontine angle: 2D versus 3D fast spin-echo sequences.

BACKGROUND AND PURPOSE: The clinical usefulness of MR cisternography of the cerebellopontine angle, applying 2D or 3D fast spin-echo sequences, has been reported recently. Our purpose was to investigate the cause of signal loss in CSF in the prepontine or cerebellopontine angle cistern on 2D FSE MR images and to compare the cisternographic effects of 2D and 3D FSE sequences. METHODS: Preliminary experiments were performed in four volunteers to assess the causes of signal loss. Initially, using a 2D cardiac-gated cine phase-contrast method with a velocity encoding value of 6 cm/s, we measured the velocity and flow pattern of CSF. Comparisons were made to assess the effects of intravoxel dephasing, amplitude of the section-selecting gradient, echo time (TE), and section thickness. Four healthy subjects and 13 patients with ear symptoms were examined, and multisection 3-mm-thick 2D images and 30-mm-slab, 1-mm-section 3D images were compared qualitatively and quantitatively. Then, 3D MR cisternography was performed in 400 patients with ear symptoms, and qualitative evaluation was performed. RESULTS: In volunteers, the average peak velocity of CSF was 1.2 cm/s. With TE = 250, CSF may move an average of 3 mm, and can be washed out of a 3-mm-thick 2D section volume. The CSF signal relative to that of a water phantom decreased gradually as TE increased on single-section 3-mm-thick 2D images. The CSF signal relative to that of the water phantom increased gradually as section thickness increased. No significant differences were noted in intravoxel dephasing and amplitude of the section-selecting gradient. The contrast-to-noise ratio (CNR) between CSF and the cerebellar peduncle, and the visibility of the cranial nerves and vertebrobasilar artery were significantly improved on 3D images in 17 subjects. In images from 400 patients, no significant signal loss in the cistern was observed using 3D FSE. CONCLUSION: CSF signal loss in thin-section 2D MR cisternography is mainly attributable to the wash-out phenomenon. 3D acquisition can reduce this phenomenon and provide thinner sections. The scan time for 3D acquisition is not excessive when a long echo train length and half-Fourier imaging are used. MR cisternography should be performed using a 3D acquisition.

Cerebellopontine Angle↗

MR imaging of the inner ear: comparison of a three-dimensional fast spin-echo sequence with use of a dedicated quadrature-surface coil with a gadolinium-enhanced spoiled gradient-recalled sequence.

PURPOSE: To prospectively evaluate the sensitivity and specificity of magnetic resonance (MR) imaging in the inner ear with a long echo train, three-dimensional (3D), asymmetric Fourier-transform, fast spin-echo (SE) sequence with use of a dedicated quadrature-surface phased-array coil to detect vestibular schwannoma in the cerebellopontine angle and the internal auditory canal. MATERIALS AND METHODS: In 205 patients (410 ears) with ear symptoms, 1.5-T MR imaging was performed with unenhanced 3D asymmetric fast SE and gadolinium-enhanced 3D gradient-recalled (SPGR) sequences with use of a quadrature surface phased-array coil. The 3D asymmetric fast SE images were reviewed by two radiologists, with the gadolinium-enhanced 3D SPGR images used as the standard of reference. RESULTS: Nineteen lesions were detected in the 410 ears (diameter range, 2-30 mm; mean, 10.5 mm +/- 6.4 [standard deviation]; five lesions were smaller than 5 mm). With 3D asymmetric fast SE, sensitivity, specificity, and accuracy, respectively, were 100%, 99.5%, and 99.5% for observer 1 and 100%, 99.7%, and 99.8% for observer 2. CONCLUSION: The unenhanced 3D asymmetric fast SE sequence with a quadrature-surface phased-array coli allows the reliable detection of vestibular schwannoma in the cerebellopontine angle and internal auditory canal.

Adolescent↗

A novel saturation transfer contrast method for 3D time-of-flight magnetic resonance angiography: a slice-selective off-resonance sinc pulse (SORS) technique.

Saturation transfer contrast (STC) techniques have been employed to decrease the signal intensity of observed water by saturating a broad proton component. The STC pulse, generally spatially nonselective, reduces the signal of brain background tissues as well as inflowing blood in 3D time-of-flight (TOF) angiography. We present a novel technique, a slice-selective off-resonance sinc pulse (SORS), which is employed to enhance inflowing blood and to suppress the signal of stationary background tissues. The STC effects of the SORS and other spatially nonselective methods influencing inflowing blood is discussed in detail. Angiograms using the SORS method are also presented to demonstrate improved vessel conspicuity. In addition, the SORS method is applicable to imagers with a whole-body RF transmitter system.

Brain↗

Determination of 2,2,2-trichloroethanol in plasma and urine by ion-exclusion chromatography.

A simple and rapid chromatographic method has been developed for the determination of 2,2,2-trichloroethanol (TCEOH) and its glucuronide in plasma and urine. A glass column (150 x 6.6 mm i.d.) packed with Aminex A-5 cation-exchange resin (potassium form) following the slurry method was used as the analytical column, and an admixture of 10 mmol l-1 potassium sulfate and 10 mmol l-1 potassium hydroxide solution as the eluent (pH 12.2). Diluted plasma samples and urine samples were directly injected into the chromatograph through a 0.45 micron membrane filter without deproteinization. The amount of TCEOH conjugated to glucuronide was determined following treatment with beta-glucuronidase (200 U) for 30 min at 37 degrees C. This allowed the concentration of free, total, and conjugated TCEOH to be determined. The calibration graph was rectilinear from 5 to 500 mg l-1 of TCEOH, with a detection limit of 3 mg l-1, 2 sigma, being the signal-to-noise ratio. The analytical recovery of TCEOH, obtained by analysing spiked plasma and urine samples, was in the range 98.4-102% and the relative standard deviation was less than 3.5%.

Adult↗

Alterations of anionic charge and/or sites of the glomerular basement membrane in the heterologous phase of passive Heymann nephritis.

Alterations of the anionic charge and/or sites of the glomerular basement membrane (GBM) in the heterologous phase of passive Heymann nephritis (PHN) were studied. Rats with PHN induced by a single injection of anti-Fx1A IgG were examined at days 1, 2, 3 and 4. The left kidney was perfused with ruthenium red (RR) solution as a cationic probe. The RR particles (= anionic sites) in the GBM were counted and expressed as the number of RR particles per unit length of GBM. For quantitative determination of the total anionic charge of the GBM, the GBM-bound ruthenium (= anionic charge) was measured with an atomic absorption spectrophotometer (AAS). Abnormal proteinuria corresponding to a decrease in anionic charge was detected at days 3 and 4. The anionic sites in the lamina rara externa (LRE) adjacent to immune complex (IC) deposits were found to have diminished earlier from day 1 onwards. This diminution was largely confined to areas adjacent to the IC deposits and was significantly correlated with the amount of urinary albumin excretion. Proteinuria in the heterologous phase of PHN would thus appear to be causally related to a decrease in the number of anionic sites in the LRE adjacent to IC deposits.

Animals↗

A novel MR angiography technique: SPEED acquisition using half-Fourier RARE.

A novel MR angiography (MRA) method, swap phase encode extended data (SPEED), was developed. Two one-shot images with the phase-encode directions swapped were collected within a single breath-hold period and processed with a maximum intensity projection (MIP) to obtain an image. In this study, a long echo train two-dimensional rapid acquisition with relaxation enhancement (RARE) sequence with half-Fourier (half-RARE) was used to obtain the pulmonary MRA images. The MIP image obtained using the SPEED technique presented promising results for pulmonary vessels.

Fourier Analysis↗

High-resolution MR images of inner ear internal anatomy using a local gradient coil at 1.5 Tesla: correlation with histological specimen.

PURPOSE: To obtain high-resolution MR images of the inner ear at 1.5 Tesla with a local gradient coil and to correlate these images with the histological specimen. MATERIALS AND METHODS: All studies were performed on a 1.5 Tesla MR unit with a local gradient coil (23 mT/m, slew rate of 107 mT/m/ms). The cranio-facial region of a cadaver was examined using 3D-fast spin echo (FSE) imaging with the voxel size of 0.27 mm x 0.27 mm x 0.5 mm in 9 h 37 min. Two normal volunteers were examined with the same system using 3D-FSE imaging with the voxel size of 0.20 mm x 0.26 mm x 1.0 mm in 57 min. These images were correlated with the cadaver images and histological specimens. RESULTS: On cadaver images, internal structures such as the macula utriculi, macula sacculi, crista ampullaris, lamina spiralis ossea, ligamentum spirale cochleae, modiolus, scala tympani, scala vestibuli, and cochlear aqueduct were visualized. On the images of both volunteers, the same structures were visualized as on the cadaver images. CONCLUSIONS: This study confirmed that high-resolution MR images obtained at 1.5 Tesla can visualize inner ear internal anatomy. Knowledge obtained in this study may be of significant value for the diagnosis of pathology in the area of the inner ear.

Aged↗