PubMed Health⌕ Search

Biomedical subjects

N J Aarts

Publications and source records attributed to N J Aarts.

At least 19 recordsLinked to original sources

[Two patients with fever, chills and pain in the right upper abdominal quadrant accompanied by hyperbilirubinaemia: pylephlebitis].

Two male patients aged 55 and 77 years, respectively, presented to the casualty department with fever, chills and right abdominal upper quadrant tenderness. They also had hyperbilirubinaemia. Based on CT scan findings and blood cultures yielding Bacteroides fragilis, a diagnosis of pylephlebitis (septic thrombophlebitis of the mesenteric veins and/or the portal vein) was made. This is a condition with a mortality rate of 10-70%. Primary sources such as diverticulitis are often seen in patients with pylephlebitis, in which bacteria are drained by the mesenteric veins and cause a thrombus in the portal system. In the two patients no primary focus was detected. They were treated with intravenous antibiotic therapy followed by oral antibiotics, and were discharged in good health. Pylephlebitis can be complicated by liver abscesses. Treatment consists of broad-spectrum antibiotics which are adjusted based on the blood cultures results. The duration of treatment is between two and six weeks, depending on the presence of liver abscesses. In patients with abscesses that cannot be drained, longer treatment may be indicated.

Abdominal Pain↗

Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis.

BACKGROUND: This was an experimental study of endovascular aortic surgery, looking at the relationship between the size of an endoleak, pressure in the aneurysm sac and the effect of thrombosis produced by coagulation. METHODS: In three pigs, 16 saccular aneurysms were connected to the aorta by various side branches with different diameters and lengths ('endoleaks'). Mean and pulse pressures were measured in the systemic circulation as well as in the aneurysm sac during the experiment. Duplex ultrasonography was used to determine whether the endoleak and the aneurysm were patent or thrombosed. Thrombosis was influenced by systemic tranexamic acid, fibrinogen in the aneurysm sac, Gelfoam in both endoleak and aneurysm sac, and by Histoacryl glue in the endoleak. RESULTS: With an open endoleak, the mean pressure in the aneurysm and the aorta was identical. Mean aneurysm pressure was lower with a thrombosed endoleak and was related to the diameter of the endoleak. Pulse pressure was recorded in the aneurysm sac when there was an open endoleak and a non-thrombosed aneurysm, and was related to the diameter of the open endoleak. Thrombosed endoleaks never produced pulse pressure in the aneurysm. If Histoacryl and Gelfoam induced thrombosis of the endoleak, the decrease in mean aneurysm pressure was identical to that resulting from the spontaneous thrombosis of endoleaks. CONCLUSION: An open endoleak results in systemic arterial pressure in the aneurysm sac. Pulse pressure is detected if the aneurysm is patent, but absent if there is complete or partial thrombosis of the aneurysm. Endoleak thrombosis, either spontaneous or by embolization, is accompanied by a decrease in mean pressure and the absence of pulse pressure in the aneurysm sac. The extent to which these experimental findings are comparable to the clinical situation represents a field of further research.

Aortic Dissection↗

Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks--comparison of a wall track system and M-mode ultrasound scanning: an in vitro and animal study.

OBJECTIVE: Pulsatile wall motion has been suggested as a means by which to evaluate abdominal aortic aneurysms after exclusion from the circulation to determine whether the treatment has been effective. The objective of this study was to investigate the relations between pulsatile wall motion and both the mean and pulse pressures within the aneurysmal sac for both patent and thrombosed endoleaks. Furthermore, we compared the measurements of pulsatile wall motion by means of M-mode ultrasound scanning and a wall track system to determine the most reliable technique. METHODS: First, interobserver and intraobserver variability of M-mode ultrasound scan measurements was determined at different pressure levels in a cow iliac artery placed in an in vitro circulation. M-mode ultrasound scanning and a wall track system were compared in the same model. Second, in an animal experiment, an aneurysm and endoleak model with both patent and thrombosed endoleaks was created. Systemic and aneurysmal mean and pulse pressures were recorded synchronically with pulsatile wall motion by means of M-mode ultrasound scanning and a wall track system. RESULTS: The intraobserver and interobserver variability values for M-mode ultrasound scan measurement in vitro were 0.11 mm (SD = 0.10 mm) and 0.15 mm (SD = 0.13 mm), respectively. In the animal study, a significant difference existed with respect to the level of pulse pressure within the aneurysmal sac between the group with pulsatile wall motion and the group without such motion (P <.0001). The presence of pulsatile wall motion was not correlated with the level of aneurysmal mean pressure. The level of pulsatile wall motion determined by means of M-mode ultrasound scanning correlated well with the level determined by means of the wall track system (r = 0. 74; P =.01). For the level of pulsatile wall motion determined by means of M-mode ultrasound scanning, a significant difference between patent and thrombosed endoleaks existed (P =.04). For detecting endoleaks, the sensitivity and specificity of pulsatile wall motion as determined by means of the wall track system were 52% and 100%, respectively, and the sensitivity and specificity of pulsatile wall motion as determined by means of M-mode ultrasound scanning were 64% and 67%, respectively. For the detection of pulse pressure in the aneurysmal sac, the sensitivity and specificity of pulsatile wall motion as determined by means of the wall track system were 76% and 100%, respectively, and the sensitivity and specificity of pulsatile wall motion as determined by means of M-mode ultrasound scanning were 90% and 71%, respectively. CONCLUSIONS: We found that pulsatile wall motion is correlated with aneurysmal pulse pressure but not with the mean level of pressure inside the aneurysm. Although measurements of pulsatile wall motion are of great theoretic value when groups of patients who have undergone endovascular aneurysm repair are being compared, this method appears to be unreliable in a clinical setting with respect to determining whether the aneurysmal sac is still pressurized in individual patients.

Animals↗

An uncommon cause of stroke in young adults.

We describe a previously healthy 48-year-old man who presented with clinical characteristics suggestive of internal carotid artery dissection, confirmed by magnetic resonance imaging. He developed a massive infarction of the left cerebral hemisphere and died after 3 days of transtentorial herniation. Post-mortem examination identified a dissection of the thoracic aorta caused by Erdheim-Gsell cystic medionecrosis, with the characteristic degeneration of the elastic fibers of the lamina media. The dissection showed an unusually large extension not only distally into both iliac arteries, but also proximally into both carotid arteries. To our knowledge, such an extensive dissection has not been described previously. Underlying vessel wall disorders of the aorta, such as Erdheim Gsell cystic medionecrosis, should be considered in young patients with spontaneous arterial dissection.

Aortic Dissection↗

Stent attachment site-related endoleakage after stent graft treatment: An in vitro study of the effects of graft size, stent type, and atherosclerotic wall changes.

OBJECTIVE: Perigraft endoleakage is a major complication of the endovascular treatment of abdominal aortic aneurysms. The factors that cause this form of endoleakage are not completely identified. The effect of sizing of the prosthesis in combination with either self-expandable or balloon-expandable stents is evaluated in this study. Further, the influence of atherosclerotic changes on endoleakage is evaluated. METHODS: Eight human abdominal aortas were assessed macroscopically at 11 sites for the presence of atherosclerotic changes with intravascular ultrasound scanning (IVUS) and with computed tomography (CT). Five aortas were placed in in vitro circulation with physiologic parameters. After the determination of the proximal and distal landing site of the stent graft, the diameter and surface measurements of the cross sections were taken. The stent graft diameters were chosen from 4-mm undersizing to 6-mm oversizing, both for Gianturco stent grafts (William Cook Europe A/S, Bjaeverskov, Denmark) and for Palmaz stent grafts (Cordis/Johnson & Johnston Co, Warren, NJ). After placement of the stent graft, the diameter and surface measurements of the aortic cross section were determined at the proximal and distal stent attachment sites. The presence and size of the folds at the stent attachment site and the interface with the aortic wall were determined with IVUS and angioscopy. Endoleakage was evaluated with angiography. After angioplasty of the stent attachment site, IVUS, angioscopy, and angiography were repeated. RESULTS: Regarding atherosclerotic changes of the aortic wall, the correlations between clinical impression and CT, clinical impression and IVUS, and CT and IVUS were high (r = 0.77, r = 0.79 and r = 0.79, respectively). For the Gianturco stent grafts, no significant relationship existed between the diameters measured before and after stent graft placement, leading to great differences in intended and achieved oversizing. The achieved oversizing was less in the case of minimal atherosclerotic changes of the aortic wall. The Gianturco stent graft followed the aortic wall closely during the heart cycle. The sizes of the folds of the fabric were clearly correlated with the achieved oversizing (r = 0.83; P =.04) and the grade of endoleakage (r = 0.88; P =.022). Angioplasty after stent graft placement had no effect on the diameter and the grade of endoleakage. Palmaz stent grafts did not follow the aortic wall during the heart cycle. A significant correlation existed between oversizing and both space between aortic wall and stent graft (r = -0.88; P =.02) and grade of endoleakage (r = 0.84; P =.036). Grade of endoleakage in the Palmaz stent graft group was less than in the Gianturco stent graft group. CONCLUSION: With the use of Gianturco stents, a great difference between intended and achieved oversizing is accomplished. The atherosclerotic changes of the aortic wall possibly affect this finding. The configuration of the Gianturco stent results in the formation of fold in the case of oversizing, which is associated with endoleakage. However, the self-expandable character of the stent leads to a close relation to the aortic wall during the heart cycle, and this may possibly accommodate future aortic neck dilation. The Palmaz stent grafts do not follow the aortic wall during the heart cycle, but they do lead to better interface between the graft and the aortic wall, which results in less endoleakage.

Angioscopy↗

Endoleak after stent-graft treatment of abdominal aortic aneurysm: a meta-analysis of clinical studies.

BACKGROUND: Endoleak is the major complication after endovascular treatment of abdominal aortic aneurysm (AAA) and its incidence seems to remain significant. Little is known about the association of device type and configuration with respect to the incidence, location, time of onset and fate of endoleakage. METHODS: A meta-analysis was performed via a Medline search of clinical studies after 1995 dealing with the endovascular treatment of AAA. Details of number of patients treated, configuration and type of endovascular device were collected. Data concerning site of origin, time of occurrence and fate of the endoleak were retrieved, along with information on change in diameter of the aneurysm with time. RESULTS: The 23 publications included reported on 1189 patients. The 1118 patients with successfully inserted transfemoral endovascular grafts experienced 270 endoleaks (24 per cent). The majority arose from the distal stent attachment site (36 per cent), were present immediately after stent-graft placement (66 per cent) and were persistent in time (37 per cent). Tube grafts were more frequently affected by endoleakage (35 per cent; P < 0.0001), especially at the distal stent attachment site (51 per cent), than bifurcated grafts (18 per cent; P = 0.004) and aortounilateral devices (20 per cent; P = 0.70). Self- expandable stent-grafts were more frequently associated with endoleaks (25 per cent) than balloon-expandable stent-grafts (17 per cent) (P = 0.037). CONCLUSION: Endovascular treatment of AAA is an evolving field. Even after the initial learning curve and attention to device-related problems, it is still accompanied by a significant number of endoleaks. Uniform presentation of results of treatment is necessary for analysing the effect of differences between patients, aneurysm morphology and device type.

Aortic Aneurysm, Abdominal↗

Abdominal aortic aneurysm measurements for endovascular repair: intra- and interobserver variability of CT measurements.

OBJECTIVES: to evaluate the intra- and interobserver variability in measurements of the aorta and iliac arteries in patients with abdominal aortic aneurysms (AAAs) considered for endovascular repair using computed tomography angiography (CTA). METHODS: the diameter of the neck, aneurysm, right and left iliac artery were measured by 5 observers in 10 consecutive patients. Measurements were performed on hard copy using a ruler and on a workstation using an electronic caliper. RESULTS: the intraobserver variability showed a decrease going from hard copy to workstation in the standard deviation of the differences of the paired observations for the neck from 3.54 mm to 1.18 mm; for the aorta from 4.16 to 1.72 mm; for the right iliac from 1.87 to 1.01 mm; for the left iliac from 2.07 to 0.87 mm. The interobserver variability showed a similar decrease for the neck in all ten pairs of observers; for the aorta in two, for the right iliac and left iliac in five. However, the difference between observers regularly exceeded 2 mm. CONCLUSION: the use of a workstation and electronic calipers results in lower intra- and interobserver variability. However, the results still show a clinically relevant difference between the observers. Therefore, it is necessary to develop an automatic observer-independent measurement technique.

Angiography↗

Endoleakage after stent-graft treatment of abdominal aneurysm: implications on pressure and imaging--an in vitro study.

BACKGROUND: Endoleakage is a fairly common problem after endovascular repair of abdominal aortic aneurysm and may prevent successful exclusion of the aneurysm. The consequences of endoleakage in terms of pressure in the aneurysmal sac are not exactly known. Moreover, the diagnosis of endoleakage is a problem because visualization of endoleaks can be difficult. METHOD: With an ex vivo model of circulation with an artificial aneurysm managed by means of a tube graft, studies were performed to evaluate precisely known diameters of endoleaks with both imaging techniques (computed tomography and digital subtraction angiography) and pressure measurements of the aneurysmal sac. The experiments were performed without endoleak (controls) and with 1.231-French (0.410 mm), 3-French (1 mm), and 7-French (2.33 mm) endoleaks. Pressure and imaging were evaluated in the absence and presence of a simulated open lumbar artery. The pressure in the prosthesis and in the aneurysmal sac were recorded simultaneously. Digital subtraction angiography with and without a Lucite acrylic plate, computed tomographic angiography, and delayed computed tomographic angiography were performed. For the first experiments, the aneurysmal sac was filled with starch solution. All tests were repeated with fresh thrombus in the aneurysmal sac. RESULTS: Each endoleak was associated with a diastolic pressure in the aneurysmal sac that was identical to diastolic systemic pressure, although the pressure curve was damped. At digital subtraction angiography without a Lucite acrylic plate, the 1.231-French (0.410 mm) endoleak was visualized without an open lumbar artery. When a Lucite acrylic plate was added, the endoleak was not visible until a lumbar artery was opened. In the presence of thrombus within the aneurysmal sac, all endoleaks were not visualized at digital subtraction angiography. At computed tomographic angiography, all endoleaks were not visualized in the absence of a thrombus mass in the aneurysmal sac. In the presence of thrombus within the aneurysmal sac, the 1.231-French (0.410 mm) endoleak became visible after opening of a simulated lumbar artery. At delayed computed tomographic angiography, all endoleaks were visualized without and with thrombus. CONCLUSION: Every endoleak, even a very small one, caused pressure greater than systemic diastolic pressure within the aneurysmal sac. However, small endoleaks were not visualized with digital subtraction angiography and computed tomographic angiography, whereas all endoleaks were visualized with a delayed computed tomographic angiography protocol. We believe that follow-up examinations after stent graft placement for aortic aneurysms should focus on pressure measurements, but until this is clinically feasible, delayed computed tomographic angiography should be performed.

Angiography, Digital Subtraction↗

Patient and staff radiation dose in fluoroscopy-guided TIPS procedures and dose reduction, using dedicated fluoroscopy exposure settings.

Fluoroscopy guided interventions, such as transjugular intrahepatic portosystemic shunt (TIPS) procedures, can results in relatively high radiation doses to patients and staff. The purpose of this study was to evaluate the possible benefit of dedicated fluoroscopy exposure factors in the reduction of doses. Doses to patients and staff were measured during fluoroscopy-guided TIPS procedures in two Dutch university hospitals. Patient doses were calculated from dose-area product (DAP) measurements, entrance beam dimensions and DAP conversion factors. Staff doses were measured outside lead aprons using electronic personal dosemeters. Average patient entrance skin dose (ESD) rate during fluoroscopy was 49 mGy min-1 (13 cases, average fluoroscopy duration 32 min) in one hospital, and 6 mGy min-1 (10 cases, average fluoroscopy duration 50 min) in the other. Estimated staff effective dose per procedure was 28 microSv average in the first hospital compared with 4 microSv average in the other. The use of dedicated fluoroscopy exposure factors, with a relatively high tube voltage and lower tube current resulted in a significant dose reduction for patient and staff in this type of radiological intervention.

Fluoroscopy↗

Assessment of the progression of emphysema by quantitative analysis of spirometrically gated computed tomography images.

RATIONALE AND OBJECTIVES: The authors assessed the progression of pulmonary emphysema by means of quantitative analysis of computed tomography images. METHODS: Twenty-three patients suffering from emphysema due to an alpha 1-antitrypsin deficiency, aged 45 +/- 7 years and exsmokers, were scanned twice with a 1-year time interval. At 90% of the vital lung capacity, slices with a thickness of 1.5 mm were acquired at the level of the carina and 5 cm above the carina; slices with a thickness of 1 cm were acquired 5 cm below the carina. The entire lung was scanned spirally at a respiratory status, corresponding with 75% of the total lung capacity at baseline. The mean lung densities (MLD) were calculated in an objective manner with new analytic software featuring automated detection of the lung contours. RESULTS: Mean lung densities decreased by 14.2 +/- 12.0 Hounsfield units (HU; P < 0.001) above the carina, by 18.1 +/- 14.4 HU (P < 0.001) at the carina level, by 23.6 +/- 15.0 HU (P < 0.001) below the carina, and by 12.8 +/- 22.2 HU (P < 0.01) for the entire lung. The decrease in MLD was most obvious in the lower lung lobes. For the same patient group, the annual decrease in the forced expiratory volume (FEV1) and the carbon monoxide-diffusion were 120 +/- 190 mL (P < 0.01) and 10 +/- 70 mmol/kg/minute ( P < 0.2), respectively. No significant correlation was found between the decrease in MLD and the decrease in FEV1. CONCLUSIONS: Progression of emphysema can be assessed in an objective manner based on the mean lung density (MLD), measured from computed tomography volume scans as well as from single-slice scans. Mean lung density has proved to be more sensitive than FEV1 and carbon monoxide-diffusion.

Adult↗

Quantitative analysis of computed tomography scans of the lungs for the diagnosis of pulmonary emphysema. A validation study of a semiautomated contour detection technique.

RATIONALE AND OBJECTIVES: To develop an analytic software package based on automated contour detection for the objective and reproducible assessment of emphysema from computed tomography (CT) scans. METHODS: A semiautomated technique was developed for the definition of lung contours in CT cross-sections followed by the assessment of pulmonary CT parameters describing the disease state. For 78 images, the semiautomated contour detection was performed and compared with contours drawn by an experienced radiologist by calculating the systematic area difference (bias) and differences in pulmonary CT parameters such as the mean lung density (MLD). In addition, intraobserver and interobserver variabilities were determined in a subset of 15 images. RESULTS: The areas enclosed by the semiautomatically detected contours were slightly larger than the manual ones (bias < 2.1%). The biases in the observer studies were smaller in the semiautomated versus the manual case (0.3% vs. 1.3%). The standard deviation of the MLD differences with a manual analysis was larger by a factor of five than in the semiautomated case. On average, manual analysis required 2 minutes, 18 seconds per lung; this time was reduced to 11.5 to 29 seconds with the semiautomated approach, depending on the respiration state. CONCLUSIONS: The semiautomated approach is preferred over the manual approach because of its higher consistency and its shorter analysis time.

Adult↗

Optimization of chest films of equalization radiography (advanced multiple beam equalization radiography). Comparison by means of a receiver operating characteristic study of simulated nodular interstitial disease.

RATIONALE AND OBJECTIVE: To optimize screen-film combinations for equalization radiography (advanced multiple beam equalization radiography [AMBER]), five different film-screen-technique combinations were compared by receiver operating characteristics study of simulated interstitial disease. MATERIALS AND METHODS: The Ortho C-Lanex Regular and the Insight Thoracic Imaging HC system were compared in conventional nonequalized technique; T-Mat G-Lanex Regular and T-Max L-Lanex Regular were compared in conventional, nonequalized, and AMBER technique; and an experimental high-contrast, low-noise, near-zero crossover film-screen combination was compared in AMBER technique. Interstitial disease was simulated by superimposing birdseed on the back of a humanoid phantom. Twenty-five posterior-anterior radiographs were made with each technique. Seven observers scored the presence of interstitial disease in each of the quadrants on a 5-point scale following receiver operating characteristic methodology. RESULTS: The highest performance was found with the experimental film-screen-AMBER combination (Az = 0.92) and the lowest with the T-Mat L-Lanex Regular-AMBER combination (Az = 0.83) and the Insight Thoracic Imaging HC system-conventional combination (Az = 0.85). T-Mat L-Lanex Regular-conventional ranked second (Az = 0.90) while T-Mat G-Lanex Regular-conventional (Az = 0.89), T-Mat L-Lanex Regular-AMBER (Az = 0.88) and Ortho-C-Lanex Regular-conventional (Az = 0.87) scored lower. CONCLUSION: Higher contrast films in AMBER improve diagnostic performance, whereas a loss of information is found if the AMBER system is combined with lower contrast films.

Humans↗

Visualization of basal pleural space and lung with advanced multiple beam equalization radiography (AMBER).

During clinical use of AMBER (Advanced Multiple Beam Equalization Radiography) it was frequently felt that the basal lung and pleural space were better appreciated than with standard chest radiography. We aimed to quantify the amount of additional relevant anatomy seen in this part region and to review the normal radiographic anatomy. Four hundred patients without known chest disease were evaluated. Two groups of 200 patients (50% female) were studied with either AMBER or standard chest radiography (140 kVp, 180 cm FFD, Kodak Tmat G film, Lanex regular screen; for both techniques). Visualization of the pleural sinuses (in percent of the transverse thoracic diameter) and the basal pulmonary vessels (4-point scale) was evaluated by a panel of 3 radiologists. The shape of the sinus was traced if sufficiently visible and subjectively evaluated. A significantly (P < 0.05) larger segment of the dorsal (41 +/- 34%) and ventral (14 +/- 15%) sinuses was seen with the AMBER technique than with the standard technique (16 +/- 21% and 9 +/- 11%, respectively). Vessel visibility was also significantly (P < 0.001) better with AMBER (3.2 +/- 0.6) than with the standard technique (1.9 +/- 0.6). The dorsal sinus showed alternatively a curved or pointed configuration.

Adult↗

[Examination of the mediastinum in staging of primary bronchial carcinoma].

Mediastinoscopy and CT are used to evaluate the mediastinum in patients with non small cell lung cancer to determine operability. Generally, the sensitivity and negative predictive value of CT are high, in a personal study in 150 patients 86% and 92%, respectively. When CT does not reveal enlarged lymph nodes, we recommend thoracotomy without mediastinoscopy. However, micrometastases in non-enlarged lymph nodes will be missed. All positive CT scans necessitate mediastinoscopy, because enlarged lymph nodes frequently are not invaded with tumour (in our study in 33%). CT used in this way will increase the percentage of positive results of mediastinoscopy. In patients with a peripheral tumour lymphogenic spread to the mediastinum is not uncommon (in our study in 22%) and mediastinal evaluation should not be omitted. In these patients mediastinoscopy is also of diagnostic value.

Adult↗

Facial thermography in the diagnosis of cerebrovascular disease and in evaluation of carotid endarterectomy.

Some 60% of strokes are due to extracranial occlusive arterial lesions, most frequently at the bifurcation of the common carotid artery. Since these lesions are accessible to endarterectomy, their prestroke diagnosis is very important. Facial thermography quickly supplies reliqble information on the circulatory area in which these lesions occur, and this information can be atraumatically obtained in an out-patient setting. The success rate of facial thermography versus aortic arch angiography was 83% and 80%, respectively, in our case material, and this rate corresponds with data in the literature. In a series of 23 patients with facial thermograms and angiograms obtained before and after endarterectomy, facial thermography proved to be a useful diagnostic and prognostic aid in neurological out-patient guidance after carotid endarterectomy. By virtue of its rapidity and atraumatic character, because it can be carried out by technicians and because the findings are suitable for computer data processing, facial thermography would seem to be suitable for potential stroke screening of a high-risk asymptomatic population.

Adult↗